02/23/2024 | 433A | PERMIT CENTER | PASS | $11 HCD CHECK DUE POST FINAL | 2/23/2024 10:44:17 AM
GRANT DEED AND TITLE REPORT IN LF
|
|
02/23/2024 | ENV HEALTH RELEASE | ALANA KONG | PASS | | |
|
04/09/2024 | PERMANENT FOUNDATION | RANDALL SMITH | PASS | | 4/9/2024 4:17:17 PM
X I 2 installed
4/9/2024 6:27:28 PM
X I 2 installed
|
|
04/09/2024 | UNDERGROUND WATER PI | RANDALL SMITH | FAIL | | 4/9/2024 6:28:18 PM
1. Provide a blue tracer wire six inches above the water pipe..
2. Provide prater pipe under test.
3. Call for reinspection when corrections are completed
|
|
04/09/2024 | UNDERGROUND CONDUIT | RANDALL SMITH | PASS | | 4/9/2024 6:28:26 PM
Ok to cover
|
|
04/09/2024 | BLOCKING/UNDERPINNIN | RANDALL SMITH | FAIL | | 4/9/2024 6:28:33 PM
1. Install a vapor barrier under mobile home.
Blocking and underpinning passed
|
|
04/09/2024 | SETBACKS | RANDALL SMITH | PASS | | |
|
04/09/2024 | SITE UTILITIES | RANDALL SMITH | CANCELLED | | |
|
04/10/2024 | **PERMIT FINAL | RANDALL SMITH | FAIL | | 4/10/2024 2:03:10 PM
Not ready
|
|
04/18/2024 | UNDERGROUND WATER PI | CHRISTOPHER ROBERTS | FAIL W/RE-INSP FEE | | 4/18/2024 10:08:19 AM
1. Tracer wire for water line not installed.
2. Water line not under test.
Complete work and call for re-inspection
|
|
04/18/2024 | CONTINUITY TEST | CHRISTOPHER ROBERTS | FAIL | | 4/18/2024 9:06:59 AM
croberts changed Inspection Type from **PERMIT FINAL to CONTINUITY TEST
4/18/2024 9:08:18 AM
croberts changed Inspection Type from **PERMIT FINAL to CONTINUITY TEST
4/18/2024 10:08:26 AM
1. Not ready. Cannot conduct continuity test due to furniture and homeowner belongings covering up all the walls and receptacles. Move all items to middle of room to conduct test.
Complete work and call for re-inspection.
|
|
04/18/2024 | SEWER(PIPE/TEST/TAP) | CHRISTOPHER ROBERTS | FAIL | | 4/18/2024 10:08:43 AM
1. No record of sewer(pipe/test/tap) inspection being done. Contractor claims inspector RS looked at septic line.
2. No clean out installed for septic line.
3. Remove skirting so septic/sewer line can be inspected.
Complete work and call for re-inspection.
|
|
04/19/2024 | CAL FIRE FINAL INSPE | CHRIS BOYD | PASS | | 4/19/2024 9:52:35 AM
Ok to final
|
|
04/22/2024 | **PERMIT FINAL | RANDALL SMITH | FAIL | | 4/22/2024 4:44:17 PM
1. Provide 5% slope for 10 ft away from the mobile home.
2. Front door and rear doors swings out on to the landing. Repair ,replace or equal.
3. Provide a 36 inch landing at the front and rear entrances.
4 Complete skirting
5. Provide a cover on exterior electrical outlet.
6. Provide light bulbs in the exterior outside light.
7. Water heater PTR plumbing must drain to the outside of the mobile home skirting. Provide PTR drain to outside.
8. Label the main panel breakers and fill the hole in the main panel.
9. Provide underfloor access.
10. Locate mh identification tag.
11. Provide a graspable handrail at both stair hand rails.
12. Call for reinspection when all corrections are completed.
Unparalleledconstructionco@gmail.com
|
|
04/22/2024 | UNDERGROUND WATER PI | RANDALL SMITH | PASS | | |
|
04/22/2024 | SEWER(PIPE/TEST/TAP) | RANDALL SMITH | PASS | | |
|
04/26/2024 | **PERMIT FINAL | WOODY TOWNSEND | PASS | | |
|