Permit No. B23-3463 Permit Type   MISCELLANEOUS Site Address   3561 CHICO RIVER RD
CHICO, CA 95928
Applied   11/29/2023 Applicant   R L CASEY CONSTRUCTION
Approved   01/29/2024 Owner   GRIFFITH JONATHAN
Issued   01/29/2024 Contractor   R L CASEY CONSTRUCTION
Parent Permit No.   Description   STUCCO (1385) INT. WALL (6FT) BATH/KITCHEN RMDL
  Notes  
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

 01/30/2024STUCCO (LATH)WOODY TOWNSENDPASS

 01/30/2024ROUGH PLUMBINGWOODY TOWNSENDFAIL1/30/2024 5:18:42 PM 1. Vent kitchen sink to exterior. 2. Vent existing gas water heater to exterior. 3. Wire and vent bath exhaust fan to exterior.

 01/30/2024ROUGH ELECTRICALWOODY TOWNSENDFAIL1/30/2024 5:18:47 PM 1. Remove all abandon wiring and wire smoke alarm in front bedroom.

 02/02/20244-WAY ROUGH FRAMEWOODY TOWNSENDPASS2/2/2024 3:59:16 PM Approved to insulate and drywall. Mechanical under separate permit.

 02/02/2024ROUGH PLUMBINGWOODY TOWNSENDPASS

 02/02/2024ROUGH ELECTRICALWOODY TOWNSENDPASSAM REQUEST

 04/26/2024**PERMIT FINALSCOTT YOUNGFAIL4/26/2024 2:19:18 PM 1. DWV pipe terminates under back porch roof. ( see attachments for pictures) 2. Unable to determine the water main into house and lines going to second dwelling. I Insulate water main to house. 3. GFCI required in laundry room. 4. Refrigerator outlet is on the same circuit as kitchen counter outlets,these are all gfci. 5. Missing receptacles in bedroom #2 6. Missing all receptacle covers and all light switch covers throughout house. 7. Seal and secure light fan combo fixtures in bathroom. 8. Vacancy sensor switch required in bathroom. 9. no hot water in hall bathroom. 10. Seal and secure master bathroom light/ exhaust fan. 11. Raise pec's line under house up off the ground and secure. 12. All electrical lines,( Romex) and old existing braid lines under house need to be cleaned up. Cut and remove any that aren't in service. 13. Install hood vent in kitchen. 14. No utilities installed, 15. Cabinets not finished. Inspection was stopped at this point , to many items not completed. Complete this list and recall inspection for an entire final inspection.

 05/17/2024**PERMIT FINALRICHARD PRATTFAIL5/17/2024 5:36:23 AM Rpratt changed Inspection Date/Time from 05/17/2024 08:00 AM to 05/17/2024 2:00 PM 5/17/2024 3:44:58 PM 1. Provide a receptacle at the kitchen counter 12' wide or greater. Right side of stove. 2. Provide a second kitchen circuit. 3. And complete original correction list: SVY 4/26/2024 2:19:18 PM 6. Missing all receptacle covers and all light switch covers throughout house. 8. Vacancy sensor switch required in bathroom 2. 12. All electrical lines,( Romex) and old existing braid lines under house need to be cleaned up. Cut and remove any that aren't in service. 14. Install stove or equal. 15. Complete this list and recall inspection for an entire final inspection.