Permit No. B23-3338 Permit Type   RESIDENTIAL Site Address   13766 W PARK DR
MAGALIA, CA 95954
Applied   11/13/2023 Applicant   ELI ENGINEERING INC
Approved   04/10/2024 Owner   EFREN SOSA
Issued   04/10/2024 Contractor   ELI ENGINEERING INC
Parent Permit No.   Description   REPL SFD(1316) GAR(617) COVD(144) FROM MP23-0005 CAMP FIRE
  Notes  
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

CAL FIRE FINAL INSPECHRIS BOYD

 03/28/2024ENV HEALTH RELEASEDANIEL GRATTANPASS

 04/26/2024SETBACKSWOODY TOWNSENDFAIL4/26/2024 3:45:00 PM 1. Locate all Property line corner monuments and pull strings.

 04/26/2024FOUNDATION/FOOTINGSWOODY TOWNSENDFAILSCHDL THIS ONE FIRST IF CAN4/26/2024 3:45:06 PM 1. Locate all property line monuments and pull string. Rear property line not marked. 2. Provide approved site plan. 3. Provide engineers approval/detail for retaining walls around garage and front porch. Approved plan details only show up to 36" stem walls not retaining.

 05/03/2024SETBACKSRICHARD PRATTFAIL W/RE-INSP FEE5/3/2024 4:37:30 AM rpratt changed Inspection Date/Time from 05/03/2024 08:00 AM to 05/03/2024 08:30 AM 5/3/2024 5:04:11 AM rpratt changed Inspection Date/Time from 05/03/2024 08:30 AM to 05/03/2024 1:30 PM 5/3/2024 1:34:57 PM 1. Move forms, footings, and rebar to be a minimum of 10' from the west elevation property line or equal. The stem wall currently sits at 9'6 .5". 2. Provide a rear property line string to verify it is with in the minimum setback distance. 3. Pay re-inspection fee and recall the inspection when completed.

 05/03/2024FOUNDATION/FOOTINGSRICHARD PRATTFAIL5/3/2024 4:37:37 AM rpratt changed Inspection Date/Time from 05/03/2024 08:00 AM to 05/03/2024 08:30 AM 5/3/2024 5:04:19 AM rpratt changed Inspection Date/Time from 05/03/2024 08:30 AM to 05/03/2024 1:30 PM 5/3/2024 1:35:06 PM Setbacks: 1. Move forms, footings, and rebar to be a minimum of 10' from the west elevation property line or equal. The stem wall currently sits at 9'6 .5". 2. Provide a rear property line string to verify it is with in the minimum setback distance. 3. Pay re-inspection fee and recall the inspection when completed. Foundation: Complete the previous correction items (Below) and pay the aforementioned re-inspection fee. "WET 4/26/2024 3:45:06 PM 1. Provide engineers approval/detail for retaining walls around garage and front porch. Approved plan details only show up to 36%34 stem walls not retaining.

 05/09/2024FOUNDATION/FOOTINGSRANDALL SMITHFAILeTRAKiT Inspection Request5/8/2024 2:47:53 PM 5/8/2024 2:47 PM ELI ENGINEERING INC Contact Name: ELI ENGINEERING INC Site Address: 13766 W PARK DR Phone: 2096134201 e-Mail: EFRENSOSA@ME.COM 5/9/2024 3:36:46 PM Setbacks: 1. Move forms, footings, and rebar to be a minimum of 10' from the west elevation property line or equal. The stem wall currently sits at 9'6 .5%34. 2. Provide a rear property line string to verify it is with in the minimum setback distance. 3. Pay re-inspection fee and recall the inspection when completed. WET 4/26/2024 3:45:06 PM 1. Provide engineers approval/detail for retaining walls around garage and front porch. Approved plan details only show up to 36%34 stem walls not retaining. Completed 5/9/2024 RS EOR a repair in attachments 1. Provide vertical rebar 18 inches on center on east and west retaining walls once west side foundation is moved to minimum 10 ft setback as per approved set of plans.

 05/09/2024SETBACKSRANDALL SMITHFAIL5/9/2024 3:37:01 PM Setbacks: 1. Move forms, footings, and rebar to be a minimum of 10' from the west elevation property line or equal. The stem wall currently sits at 9'6 .5%34. 2. Provide a rear property line string to verify it is with in the minimum setback distance. 3. Pay re-inspection fee and recall the inspection when completed. WET 4/26/2024 3:45:06 PM 1. Provide engineers approval/detail for retaining walls around garage and front porch. Approved plan details only show up to 36%34 stem walls not retaining. Completed 5/9/2024 RS 1. Provide vertical rebar 18 inches on center on east and west retaining walls once west side foundation is moved to minimum 10 ft setback as per approved set of plans.

 05/16/2024FORMS/STEEL/HOLDOWNSSCOTT YOUNGFAILeTRAKiT Inspection Request5/14/2024 3:02:46 PM 5/14/2024 3:02 PM ELI ENGINEERING INC Contact Name: ELI ENGINEERING INC Site Address: 13766 W PARK DR Phone: 2096134201 e-Mail: EFRENSOSA@ME.COM 5/17/2024 9:46:46 AM Back property set backs not in place. Find property pins and have string lines up For next inspection,