| ENV HEALTH RELEASE | BC Land Use | | | |
|
11/27/2023 | FOUNDATION/FOOTINGS | CHRISTOPHER ROBERTS | PASS | | 11/27/2023 11:38:31 AM
Foundation/footings - Approved
|
|
12/18/2023 | ROOF FRAME/SHEATHING | CHRISTOPHER ROBERTS | PARTIAL | AM REQUEST | 12/18/2023 2:17:47 PM
Roof nail/sheathing - Approved
** OKAY TO COVER
** No inspection conducted on trusses due to calcs not being on-site or on file. Inspect at 4-way.
|
|
01/19/2024 | 4-WAY ROUGH FRAME | SCOTT YOUNG | FAIL | | 1/19/2024 6:17:00 PM
Permit is only for a front portion of house, the entire house has been remodeled from the ground up.
Have plans revised and approved by Butte County.
There have been inspections that have not been done in order to reach 4-way at this point.
Some pictures have been taken and are in attachments
Gas test on house did pass,
DWV was under test and did pass.
Entire house shearwall nail at 6/12
Do not proceed with any work until the plans have been revised by the county.
|
|
04/26/2024 | 4-WAY ROUGH FRAME | CHRISTOPHER ROBERTS | PARTIAL | | 4/26/2024 8:18:12 AM
croberts changed Inspection Date/Time from 04/26/2024 11:30 AM to 04/26/2024 11:00 AM
4/26/2024 2:20:01 PM
1. House needs to be weatherproofed prior to 4-way inspection.
2. Provide strap for break in bottom plate and fill in gap for HDU rear of house.
3. Cut in attic hatch.
4. Finish installing eave block venting and soffit venting.
** okay to insulate and Sheetrock.
|
|
04/26/2024 | SHEARWALL/B.W.P.-EXT | CHRISTOPHER ROBERTS | PASS | | 4/26/2024 2:20:21 PM
Shearwall ext. - Approved
Okay to wrap.
|
|
| 4-WAY ROUGH FRAME | DSINSPECTION | | | |
|