04/28/2024
1:08 PM

Butte County
Department of Development Services

Main: 530.552.3700
Automated Inspection Phone Line: 530.538.4365
Online Inspection Scheduling / Payments / Renewals:
ButteCounty.net/DDS

 
Permit No. B19-0552 Permit Type   RESIDENTIAL Site Address   3431 SUNVIEW RD
PARADISE, CA 95969
Applied   02/28/2019 Applicant   ZIGAN, JIM/ANDREA
Approved   05/08/2019 Owner   ZIGAN, JAMES & ANDREA
Issued   05/09/2019 Contractor   O/B
Parent Permit No.   Description   SFD (2665) GAR (880) COV (495)
  Notes  
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

 06/26/2019SETBACKSWOODY TOWNSENDPASS030266-02 MSG! -Msg! Scheduled by IVR.

 06/26/2019UNDER SLAB PLUMBINGWOODY TOWNSENDPASS030266-01 MSG! -Msg! Scheduled by IVR.

 07/03/2019PRE-SLABSCOTT YOUNGPARTIAL030266-04 - Scheduled by IVR.7/3/2019 12:28:10 PM Inspection for pre slab on house only approved. Garage and cabana still pending approval. Inspection required.

 07/03/2019FOUNDATION/FOOTINGSSCOTT YOUNGPASS030266-03 - Scheduled by IVR.

 07/19/2019PRE-SLABLARRY AKERSPARTIAL031169-01 MSG! -Msg! Scheduled by IVR.7/19/2019 3:22:00 PM Garage slab approved

 09/10/2019SHEARWALL/B.W.P.-INTADAM KINGSLEYFAIL9/10/2019 5:05:13 PM 1. Anchor bolts not provided 4'oc per Shearwall schedule. Provide written verification from engineer of record AB's not needed at interior Shearwalls or equal. 2. Truss block not provided above bedroom Shearwall per detail 19/SD. Provide blocking or written approval from engineer of record.

 09/10/2019ROOF NAILADAM KINGSLEYFAIL9/10/2019 5:05:33 PM 1. 4' CS16 straps not Installed at rear patio rafters per detail 20/SD. T&G roof deck installed. Provide fix from Engineer of Record. 2. Missing truss block at interior Shearwall. See interior sw inspection corrections. Verify screw spacing to roof sheathing or equal.

 09/10/2019ROOF FRAME/SHEATHINGADAM KINGSLEYFAIL9/10/2019 5:05:45 PM 1. LPT4 clips not installed at rear porch gable end beam to plates per detail 20/SD. Provide required hardware or written approval from engineer of record.

 09/10/2019SHEARWALL/B.W.P.-EXTADAM KINGSLEYFAIL9/10/2019 5:05:22 PM 1. Missing required anchor bolts at several locations throughout. Install per plans or equal. 2. Electric panel cut into engineered Shearwall. Provide written approval from engineer of record or EOR fix for Shearwall perforation.

 09/17/2019ROOF NAILMIKE KNIGHTPASS033918-01 MSG! -Msg! Scheduled by IVR.9/17/2019 3:49:37 PM All prior corrections addressed for roof nail and shear walls. Also, re-inspected roof nail. 9/18/2019 7:21:24 AM All prior corrections addressed for roof nail and shear walls. Also, re-inspected roof nail.

 09/30/2019ROUGH ELECTRICALSCOTT YOUNGPASS034450-01 MSG! -Msg! Scheduled by IVR.9/30/2019 3:21:22 PM Temp power tag.

 10/22/20194-WAY ROUGH FRAMESCOTT YOUNGFAIL10/22/2019 4:56:01 PM No one onsite, no plans left and place locked up. Call for reinspection. 10/22/2019 4:57:04 PM No one onsite, no plans left and place locked up. Call for reinspection.

 10/25/20194-WAY ROUGH FRAMEPHILLIP MYERSPARTIALPartial, Patio cover only10/25/2019 3:07:41 PM This Inspection was for the inclosed patio framing

 11/05/2019ROUGH PLUMBINGSCOTT YOUNGCANCELLEDVOIDED (SVY 11/6/2019)11/6/2019 7:50:42 AM Inspection voided by SVY. Most recent remarks follow: 035738-01 - Scheduled by IVR.

 11/05/2019ROUGH MECHANICALSCOTT YOUNGCANCELLEDVOIDED (SVY 11/6/2019)11/6/2019 7:50:58 AM Inspection voided by SVY. Most recent remarks follow: 035738-02 - Scheduled by IVR.

 11/05/20194-WAY ROUGH FRAMESCOTT YOUNGCANCELLEDVOIDED (SVY 11/6/2019)11/5/2019 5:03:36 PM unable to do 4 way rough, sprinkler plans have not been issued. 11/6/2019 7:51:08 AM Inspection voided by SVY. Most recent remarks follow: 035738-03 - Scheduled by IVR.

 11/06/2019SHOWER PAN/TUB TESTSCOTT YOUNGPASS035738-05 MSG! -Msg! Scheduled by IVR.

 11/06/2019GAS PIPINGSCOTT YOUNGPASS035738-04 - Scheduled by IVR.

 11/06/2019ROUGH ELECTRICALSCOTT YOUNGFAILeTRAKiT Inspection Request11/4/2019 10:00:01 AM 11/4/2019 10:00 AM Andrea zigan Plans are in garage, code to key box 0420; key box located in garage to the right of the door. Contact Name: Andrea zigan Site Address: 3431 SUNVIEW RD Phone: 5305926686 e-Mail: jimmyz34@sbcglobal.net 11/6/2019 2:25:51 PM Grounds not crimped on any boxes

 11/14/20194-WAY ROUGH FRAMEPHILLIP MYERSPASS036026-01 - Scheduled by IVR.3/2/2020 8:03:11 AM All frame and rough complete

 12/05/2019STUCCO (LATH)SCOTT YOUNGPASS036769-01 MSG! -Msg! Scheduled by IVR.

 02/28/1850NPDESQUENTIN CARTERVOIDED (ALK 3/2/2020)3/2/2020 7:34:19 AM Inspection voided by ALK.

PLUMBING FINALADAM KINGSLEYVOIDED (ALK 3/2/2020)3/2/2020 7:34:35 AM Inspection voided by ALK. Most recent remarks follow: 039511-03 - Scheduled by IVR.

ELECTRICAL FINALADAM KINGSLEYVOIDED (ALK 3/2/2020)3/2/2020 7:34:51 AM Inspection voided by ALK. Most recent remarks follow: 039511-01 MSG! -Msg! Scheduled by IVR.

MECHANICAL FINALADAM KINGSLEYVOIDED (ALK 3/2/2020)3/2/2020 7:35:05 AM Inspection voided by ALK. Most recent remarks follow: 039511-02 - Scheduled by IVR.

 03/02/2020**PERMIT FINALSCOTT YOUNGFAIL039511-04 - Scheduled by IVR.3/2/2020 12:30:40 PM Not ready! Appliances are not set, electrical not finished. Sinks and plumbing not done. 3/2/2020 12:30:57 PM Not ready! Appliances are not set, electrical not finished. Sinks and plumbing not done.

MECHANICAL FINALADAM KINGSLEYVOIDED (ALK 3/9/2020)3/9/2020 8:05:26 AM Inspection voided by ALK.

 03/06/2020TAG LPGWOODY TOWNSENDPASS

 03/11/2020**PERMIT FINALADAM KINGSLEYFAIL3/12/2020 8:01:10 AM 1. Provide GFCI protection at the following required locations: Exterior receptacles at rear patio/cabana; South wall of garage; master bath receptacle left side; Kitchen counter top receptacles. 2. Provide caulk/seal at water closet bases. 3. Provide occupancy controls for min one luminaire at bathrooms, pantry & laundry areas. 4. Attic access in the garage requires self closing/latching or equal (attic is open to entire building attic). 5. Provide backflow protection at exterior hose bibs. Install vacuum breaker or equal. 6. Provide min 5' clearance between spa water edge and disconnect. Disconnect shall also be within sight of the spa. 7. Provide Butte County Environmental Health & CalFire Final clearance.

 03/13/2020ENV HEALTH RELEASEDARREN JONESPASS

 03/13/2020CAL FIRE FINAL INSPECHRIS BOYDPASS3/13/2020 11:57:53 AM Ok to Final.

 03/16/2020ELECTRICAL FINALSCOTT YOUNGFAIL040040-01 - Scheduled by IVR.3/16/2020 12:14:38 PM Not ready for final. Agra Electric was there working on an electrical issue.

 03/17/2020**PERMIT FINALSCOTT YOUNGPASS040133-01 - Scheduled by IVR.3/17/2020 10:58:56 AM Spoke with Woody about the tree removal program, they should not have been linked to that program. They live in a private sub division and the fire did not reach that area. ok to final.