06/26/2019 | SETBACKS | WOODY TOWNSEND | PASS | 030266-02 MSG! -Msg! Scheduled by IVR. | |
|
06/26/2019 | UNDER SLAB PLUMBING | WOODY TOWNSEND | PASS | 030266-01 MSG! -Msg! Scheduled by IVR. | |
|
07/03/2019 | PRE-SLAB | SCOTT YOUNG | PARTIAL | 030266-04 - Scheduled by IVR. | 7/3/2019 12:28:10 PM
Inspection for pre slab on house only approved.
Garage and cabana still pending approval. Inspection required.
|
|
07/03/2019 | FOUNDATION/FOOTINGS | SCOTT YOUNG | PASS | 030266-03 - Scheduled by IVR. | |
|
07/19/2019 | PRE-SLAB | LARRY AKERS | PARTIAL | 031169-01 MSG! -Msg! Scheduled by IVR. | 7/19/2019 3:22:00 PM
Garage slab approved
|
|
09/10/2019 | SHEARWALL/B.W.P.-INT | ADAM KINGSLEY | FAIL | | 9/10/2019 5:05:13 PM
1. Anchor bolts not provided 4'oc per Shearwall schedule. Provide written verification from engineer of record AB's not needed at interior Shearwalls or equal.
2. Truss block not provided above bedroom Shearwall per detail 19/SD. Provide blocking or written approval from engineer of record.
|
|
09/10/2019 | ROOF NAIL | ADAM KINGSLEY | FAIL | | 9/10/2019 5:05:33 PM
1. 4' CS16 straps not Installed at rear patio rafters per detail 20/SD. T&G roof deck installed. Provide fix from Engineer of Record.
2. Missing truss block at interior Shearwall. See interior sw inspection corrections. Verify screw spacing to roof sheathing or equal.
|
|
09/10/2019 | ROOF FRAME/SHEATHING | ADAM KINGSLEY | FAIL | | 9/10/2019 5:05:45 PM
1. LPT4 clips not installed at rear porch gable end beam to plates per detail 20/SD. Provide required hardware or written approval from engineer of record.
|
|
09/10/2019 | SHEARWALL/B.W.P.-EXT | ADAM KINGSLEY | FAIL | | 9/10/2019 5:05:22 PM
1. Missing required anchor bolts at several locations throughout. Install per plans or equal.
2. Electric panel cut into engineered Shearwall. Provide written approval from engineer of record or EOR fix for Shearwall perforation.
|
|
09/17/2019 | ROOF NAIL | MIKE KNIGHT | PASS | 033918-01 MSG! -Msg! Scheduled by IVR. | 9/17/2019 3:49:37 PM
All prior corrections addressed for roof nail and shear walls. Also, re-inspected roof nail.
9/18/2019 7:21:24 AM
All prior corrections addressed for roof nail and shear walls. Also, re-inspected roof nail.
|
|
09/30/2019 | ROUGH ELECTRICAL | SCOTT YOUNG | PASS | 034450-01 MSG! -Msg! Scheduled by IVR. | 9/30/2019 3:21:22 PM
Temp power tag.
|
|
10/22/2019 | 4-WAY ROUGH FRAME | SCOTT YOUNG | FAIL | | 10/22/2019 4:56:01 PM
No one onsite, no plans left and place locked up. Call for reinspection.
10/22/2019 4:57:04 PM
No one onsite, no plans left and place locked up. Call for reinspection.
|
|
10/25/2019 | 4-WAY ROUGH FRAME | PHILLIP MYERS | PARTIAL | Partial, Patio cover only | 10/25/2019 3:07:41 PM
This Inspection was for the inclosed patio framing
|
|
11/05/2019 | ROUGH PLUMBING | SCOTT YOUNG | CANCELLED | VOIDED (SVY 11/6/2019) | 11/6/2019 7:50:42 AM
Inspection voided by SVY. Most recent remarks follow: 035738-01 - Scheduled by IVR.
|
|
11/05/2019 | ROUGH MECHANICAL | SCOTT YOUNG | CANCELLED | VOIDED (SVY 11/6/2019) | 11/6/2019 7:50:58 AM
Inspection voided by SVY. Most recent remarks follow: 035738-02 - Scheduled by IVR.
|
|
11/05/2019 | 4-WAY ROUGH FRAME | SCOTT YOUNG | CANCELLED | VOIDED (SVY 11/6/2019) | 11/5/2019 5:03:36 PM
unable to do 4 way rough, sprinkler plans have not been issued.
11/6/2019 7:51:08 AM
Inspection voided by SVY. Most recent remarks follow: 035738-03 - Scheduled by IVR.
|
|
11/06/2019 | SHOWER PAN/TUB TEST | SCOTT YOUNG | PASS | 035738-05 MSG! -Msg! Scheduled by IVR. | |
|
11/06/2019 | GAS PIPING | SCOTT YOUNG | PASS | 035738-04 - Scheduled by IVR. | |
|
11/06/2019 | ROUGH ELECTRICAL | SCOTT YOUNG | FAIL | eTRAKiT Inspection Request | 11/4/2019 10:00:01 AM
11/4/2019 10:00 AM Andrea zigan
Plans are in garage, code to key box 0420; key box located in garage to the right of the door.
Contact Name: Andrea zigan
Site Address: 3431 SUNVIEW RD
Phone: 5305926686
e-Mail: jimmyz34@sbcglobal.net
11/6/2019 2:25:51 PM
Grounds not crimped on any boxes
|
|
11/14/2019 | 4-WAY ROUGH FRAME | PHILLIP MYERS | PASS | 036026-01 - Scheduled by IVR. | 3/2/2020 8:03:11 AM
All frame and rough complete
|
|
12/05/2019 | STUCCO (LATH) | SCOTT YOUNG | PASS | 036769-01 MSG! -Msg! Scheduled by IVR. | |
|
02/28/1850 | NPDES | QUENTIN CARTER | | VOIDED (ALK 3/2/2020) | 3/2/2020 7:34:19 AM
Inspection voided by ALK.
|
|
| PLUMBING FINAL | ADAM KINGSLEY | | VOIDED (ALK 3/2/2020) | 3/2/2020 7:34:35 AM
Inspection voided by ALK. Most recent remarks follow: 039511-03 - Scheduled by IVR.
|
|
| ELECTRICAL FINAL | ADAM KINGSLEY | | VOIDED (ALK 3/2/2020) | 3/2/2020 7:34:51 AM
Inspection voided by ALK. Most recent remarks follow: 039511-01 MSG! -Msg! Scheduled by IVR.
|
|
| MECHANICAL FINAL | ADAM KINGSLEY | | VOIDED (ALK 3/2/2020) | 3/2/2020 7:35:05 AM
Inspection voided by ALK. Most recent remarks follow: 039511-02 - Scheduled by IVR.
|
|
03/02/2020 | **PERMIT FINAL | SCOTT YOUNG | FAIL | 039511-04 - Scheduled by IVR. | 3/2/2020 12:30:40 PM
Not ready! Appliances are not set, electrical not finished. Sinks and plumbing not done.
3/2/2020 12:30:57 PM
Not ready! Appliances are not set, electrical not finished. Sinks and plumbing not done.
|
|
| MECHANICAL FINAL | ADAM KINGSLEY | | VOIDED (ALK 3/9/2020) | 3/9/2020 8:05:26 AM
Inspection voided by ALK.
|
|
03/06/2020 | TAG LPG | WOODY TOWNSEND | PASS | | |
|
03/11/2020 | **PERMIT FINAL | ADAM KINGSLEY | FAIL | | 3/12/2020 8:01:10 AM
1. Provide GFCI protection at the following required locations: Exterior receptacles at rear patio/cabana; South wall of garage; master bath receptacle left side; Kitchen counter top receptacles.
2. Provide caulk/seal at water closet bases.
3. Provide occupancy controls for min one luminaire at bathrooms, pantry & laundry areas.
4. Attic access in the garage requires self closing/latching or equal (attic is open to entire building attic).
5. Provide backflow protection at exterior hose bibs. Install vacuum breaker or equal.
6. Provide min 5' clearance between spa water edge and disconnect. Disconnect shall also be within sight of the spa.
7. Provide Butte County Environmental Health & CalFire Final clearance.
|
|
03/13/2020 | ENV HEALTH RELEASE | DARREN JONES | PASS | | |
|
03/13/2020 | CAL FIRE FINAL INSPE | CHRIS BOYD | PASS | | 3/13/2020 11:57:53 AM
Ok to Final.
|
|
03/16/2020 | ELECTRICAL FINAL | SCOTT YOUNG | FAIL | 040040-01 - Scheduled by IVR. | 3/16/2020 12:14:38 PM
Not ready for final. Agra Electric was there working on an electrical issue.
|
|
03/17/2020 | **PERMIT FINAL | SCOTT YOUNG | PASS | 040133-01 - Scheduled by IVR. | 3/17/2020 10:58:56 AM
Spoke with Woody about the tree removal program, they should not have been linked to that program. They live in a private sub division and the fire did not reach that area. ok to final.
|
|