| ENV HEALTH RELEASE | YVETTE CASTANON | PASS | | |
|
02/28/1850 | NPDES | PWLANDDEV | | VOIDED (KH1 7/14/2022) | 7/14/2022 2:31:37 PM
Inspection voided by KH1.
|
|
08/18/2022 | FOUNDATION/FOOTINGS | ADAM KINGSLEY | PASS | | 8/18/2022 7:44:00 PM
Garage and MH concrete perimeter footing and setbacks -approved.
No eufer ground installed.
|
|
01/23/2023 | SHEARWALL/B.W.P.-EXT | RICHARD PRATT | FAIL | 064742-01 - Scheduled by IVR. | 1/23/2023 6:05:44 AM
rpratt changed Inspection Date/Time from 01/23/2023 08:00 AM to 01/23/2023 2:00 PM
1/23/2023 3:07:59 PM
See rough framing for notes.
|
|
01/23/2023 | ROUGH FRAME | RICHARD PRATT | FAIL | 064742-03 - Scheduled by IVR. | 1/23/2023 6:05:51 AM
rpratt changed Inspection Date/Time from 01/23/2023 08:00 AM to 01/23/2023 2:00 PM
1/23/2023 3:08:04 PM
Provide full structural support for top plate breaks.
Finish nailing all H1 Truss hardware to the trusses.
Properly nail king studs to the headers.
Properly nail sheathing to the trusses where marked.
Renail sheathing where fasteners are over driven - check throughout.
Recall inspection when completed.
|
|
01/23/2023 | ROOF NAIL | RICHARD PRATT | FAIL | 064742-02 - Scheduled by IVR. | 1/23/2023 6:05:57 AM
rpratt changed Inspection Date/Time from 01/23/2023 08:00 AM to 01/23/2023 2:00 PM
1/23/2023 3:08:09 PM
See rough framing for notes.
|
|
01/27/2023 | SHEARWALL/B.W.P.-EXT | RANDALL SMITH | PASS | | 1/27/2023 2:02:51 PM
All previous corrections were completed.
|
|
01/27/2023 | ROOF NAIL | RANDALL SMITH | PASS | | 1/27/2023 2:02:58 PM
All previous corrections were completed
|
|
01/27/2023 | ROUGH FRAME | RANDALL SMITH | PASS | 064859-01 - Scheduled by IVR. | 1/27/2023 2:02:40 PM
rjsmith changed Inspection Type from SHEARWALL/B.W.P.-EXT to ROUGH FRAME
1/27/2023 2:03:54 PM
All previous corrections were completed
|
|
03/24/2023 | CAL FIRE FINAL INSPE | CHRIS BOYD | PASS | | |
|
03/24/2023 | **PERMIT FINAL | RANDALL SMITH | FAIL | 065672-01 - Scheduled by IVR. | 3/24/2023 3:49:11 PM
1. Provide approval from Cal Fire.
2. Provide a vent at the gable end as per plans
3. Provide a fire wall running to the roof line separating the garage from the SFD. Cover holes in the firewall next to the stairs.
4. Call for re-inspection when corrections are completed
3/24/2023 3:53:23 PM
1. Provide approval from Cal Fire.
2. Provide a vent at the gable end as per plans
3. Provide a fire wall running to the roof line separating the garage from the SFD. Cover holes in the firewall next to the stairs.
4. Call for re-inspection when corrections are completed
3/24/2023 3:54:54 PM
1. Provide approval from Cal Fire.
2. Provide a vent at the gable end as per plans
3. Provide a fire wall running to the roof line separating the garage from the SFD. Cover holes in the firewall next to the stairs.
4. Call for re-inspection when corrections are completed
|
|
04/12/2023 | **PERMIT FINAL | RANDALL SMITH | PASS | 066011-01 - Scheduled by IVR. | 4/12/2023 4:03:07 PM
All previous corrections have been completed
4/12/2023 4:04:09 PM
All previous corrections have been completed
|
|