10/01/2021 | NPDES | PWLANDDEV | NOT REQUIRED | | |
|
10/01/2021 | PW FINAL | PWROADS | PASS | | |
|
05/04/2022 | FOUNDATION/FOOTINGS | RICHARD PRATT | PASS | eTRAKiT Inspection Request | 5/3/2022 6:59:08 AM
5/3/2022 6:59 AM BLU NELSON CONSTRUCTION
Contact Name: BLU NELSON CONSTRUCTION
Site Address: 1649 18TH ST
Phone: 5307125516
e-Mail: blunelsonconstruction@gmail.com
5/4/2022 11:41:41 AM
Forms footings and rebar - Approved
Eufer ground installed
|
|
05/18/2022 | UNDERFLOOR PLUMBING | RANDALL SMITH | PASS | eTRAKiT Inspection Request | 5/17/2022 8:28:48 AM
5/17/2022 8:28 AM BLU NELSON CONSTRUCTION
Contact Name: BLU NELSON CONSTRUCTION
Site Address: 1649 18TH ST
Phone: 5307125516
e-Mail: blunelsonconstruction@gmail.com
5/18/2022 4:54:30 PM
Pass ok to proceed
|
|
05/18/2022 | UNDERFLOOR FRAMING | RANDALL SMITH | PASS | | 5/18/2022 4:55:19 PM
Passed ok to proceed
|
|
06/21/2022 | TAG ELECTRIC | CHRISTOPHER ROBERTS | PASS | eTRAKiT Inspection Request | 6/15/2022 4:24:41 PM
6/15/2022 4:24 PM BLU NELSON CONSTRUCTION
Contact Name: BLU NELSON CONSTRUCTION
Site Address: 1649 18TH ST
Phone: 5307125516
e-Mail: blunelsonconstruction@gmail.com
6/22/2022 6:23:06 AM
Tag electric - approved
Ready to energize
|
|
06/21/2022 | SHEARWALL/B.W.P.-EXT | CHRISTOPHER ROBERTS | FAIL | eTRAKiT Inspection Request | 6/15/2022 4:24:41 PM
6/15/2022 4:24 PM BLU NELSON CONSTRUCTION
Contact Name: BLU NELSON CONSTRUCTION
Site Address: 1649 18TH ST
Phone: 5307125516
e-Mail: blunelsonconstruction@gmail.com
6/22/2022 6:23:12 AM
1. Exterior sheer wall needs to be complete. Missing section of 3/8" sheathing next to upgraded service panel.
2. Exterior sheer wall missing nails in multiple locations throughout. (Marked with blue crayon).
Call for re-inspection when completed.
|
|
06/21/2022 | ROOF NAIL | CHRISTOPHER ROBERTS | FAIL | eTRAKiT Inspection Request | 6/15/2022 4:24:41 PM
6/15/2022 4:24 PM BLU NELSON CONSTRUCTION
Contact Name: BLU NELSON CONSTRUCTION
Site Address: 1649 18TH ST
Phone: 5307125516
e-Mail: blunelsonconstruction@gmail.com
6/22/2022 6:23:21 AM
1. Multiple "shiners" located on first 2 rafters closest to house. Need to remove and re-nail sheathing securely to rafter.
2. Entire section of roof is covered and stapled with tar paper. Need to completely remove paper for Roof Nail inspection.
Call for re-inspection when completed.
|
|
07/13/2022 | SHEARWALL/B.W.P.-EXT | RANDALL SMITH | PASS | eTRAKiT Inspection Request | 7/11/2022 8:26:37 AM
7/11/2022 8:26 AM BLU NELSON CONSTRUCTION
Contact Name: BLU NELSON CONSTRUCTION
Site Address: 1649 18TH ST
Phone: 5307125516
e-Mail: blunelsonconstruction@gmail.com
7/13/2022 4:06:14 PM
All corrections from previous ext shear wall inspection have been completed.
7/13/2022 4:06:41 PM
All corrections from previous ext shear wall inspection have been completed.
|
|
07/13/2022 | ROOF FRAME/SHEATHING | RANDALL SMITH | FAIL | eTRAKiT Inspection Request | 7/11/2022 8:26:37 AM
7/11/2022 8:26 AM BLU NELSON CONSTRUCTION
Contact Name: BLU NELSON CONSTRUCTION
Site Address: 1649 18TH ST
Phone: 5307125516
e-Mail: blunelsonconstruction@gmail.com
7/13/2022 4:06:19 PM
1. Provide approved truss calculations on site.
2. Install H-1 clips, H 2.5 or equal to trusses as per plans.
3. Call for reinspection when corrections are completed.
* Roof nailing passed inspection and ok to dry in.
* Ext shear wall nailing passed. Ok to dry in.
* 4 way not ready till building is dried in.
7/13/2022 4:06:46 PM
1. Provide approved truss calculations on site.
2. Install H-1 clips, H 2.5 or equal to trusses as per plans.
3. Call for reinspection when corrections are completed.
* Roof nailing passed inspection and ok to dry in.
* Ext shear wall nailing passed. Ok to dry in.
* 4 way not ready till building is dried in.
|
|
07/13/2022 | 4-WAY ROUGH FRAME | RANDALL SMITH | FAIL | eTRAKiT Inspection Request | 7/11/2022 8:26:37 AM
7/11/2022 8:26 AM BLU NELSON CONSTRUCTION
Contact Name: BLU NELSON CONSTRUCTION
Site Address: 1649 18TH ST
Phone: 5307125516
e-Mail: blunelsonconstruction@gmail.com
7/13/2022 4:06:53 PM
Not ready for 4 way as addition is not dried
1. Provide approved truss calculations on site.
2. Install H-1 clips, H 2.5 or equal to trusses as per approved plans.
3. Call for reinspection when corrections are completed.
* Roof nailing passed inspection and ok to dry in.
* Ext shear wall nailing passed. Ok to dry in.
* 4 way not ready till building is dried in.
|
|
07/21/2022 | 4-WAY ROUGH FRAME | CHRISTOPHER ROBERTS | PASS | MORNING request | 7/21/2022 4:07:32 PM
|
|
08/16/2022 | SHOWER PAN/TUB TEST | RANDALL SMITH | PASS | eTRAKiT Inspection Request | 8/15/2022 11:31:53 AM
8/15/2022 11:31 AM BLU NELSON CONSTRUCTION
Contact Name: BLU NELSON CONSTRUCTION
Site Address: 1649 18TH ST
Phone: 5307125516
e-Mail: blunelsonconstruction@gmail.com
8/16/2022 4:14:52 PM
Passed
8/16/2022 9:26:41 PM
Passed
|
|
02/28/1850 | TAG ELECTRIC | DSINSPECTION | | VOIDED (RDP 12/4/2022) | 6/19/2022 5:16:53 PM
6/19/2022 5:16 PM BLU NELSON CONSTRUCTION
Contact Name: BLU NELSON CONSTRUCTION
Site Address: 1649 18TH ST
Phone: 5307125516
e-Mail: blunelsonconstruction@gmail.com
12/4/2022 1:18:38 PM
Inspection voided by RDP. Most recent remarks follow: eTRAKiT Inspection Request
|
|
02/28/1850 | UNDERFLOOR PLUMBING | DSINSPECTION | | VOIDED (RDP 12/4/2022) | 5/17/2022 8:26:37 AM
5/17/2022 8:26 AM BLU NELSON CONSTRUCTION
Contact Name: BLU NELSON CONSTRUCTION
Site Address: 1649 18TH ST
Phone: 5307125516
e-Mail: blunelsonconstruction@gmail.com
12/4/2022 1:18:49 PM
Inspection voided by RDP. Most recent remarks follow: eTRAKiT Inspection Request
|
|
| ENV HEALTH RELEASE | BC Land Use | VOID | | 12/5/2022 10:11:22 AM
CITY SEWER NO REVIEW REQUIRED
|
|
12/05/2022 | **PERMIT FINAL | SCOTT YOUNG | PASS | eTRAKiT Inspection Request | 12/1/2022 6:39:13 AM
12/1/2022 6:39 AM BLU NELSON CONSTRUCTION
Contact Name: BLU NELSON CONSTRUCTION
Site Address: 1649 18TH ST
Phone: 5307125516
e-Mail: blunelsonconstruction@gmail.com
12/6/2022 6:22:38 AM
Final pending environmental health sign off. Received call from homeowner, they are on city sewer, environmental health inspection not required.
Ok to final.
|
|