02/28/1850 | NPDES | PWLANDDEV | | VOIDED (RLF 9/2/2021) | 9/2/2021 8:08:47 AM
Inspection voided by RLF.
|
|
09/02/2021 | PW FINAL | PWROADS | PASS | | |
|
09/24/2021 | UNDERFLOOR PLUMBING | RICHARD PRATT | PASS | eTRAKiT Inspection Request | 9/23/2021 8:25:43 AM
9/23/2021 8:25 AM BLU NELSON CONSTRUCTION
Contact Name: BLU NELSON CONSTRUCTION
Site Address: 1338 ESTOM WAY LOT 24
Phone: 5307125516
e-Mail: blunelsonconstruction@gmail.com
9/24/2021 6:23:07 AM
rpratt changed Inspection Date/Time from 09/24/2021 08:00 AM to 09/24/2021 09:00 AM
9/24/2021 9:26:48 AM
Underslab plumbing- on test, and with proper slope. - Approved
|
|
09/24/2021 | FOUNDATION/FOOTINGS | RICHARD PRATT | FAIL | eTRAKiT Inspection Request | 9/23/2021 8:25:43 AM
9/23/2021 8:25 AM BLU NELSON CONSTRUCTION
Contact Name: BLU NELSON CONSTRUCTION
Site Address: 1338 ESTOM WAY LOT 24
Phone: 5307125516
e-Mail: blunelsonconstruction@gmail.com
9/24/2021 6:23:14 AM
rpratt changed Inspection Date/Time from 09/24/2021 08:00 AM to 09/24/2021 09:00 AM
9/24/2021 9:26:56 AM
1. Install rebar and Alternate required hooks per plan 2/SD2 - check throughout
2. Provide 3" minimum clearance to soil for rebar in footings and pier footings - check throughout
3. Remove loose fill and debris from the footings - check throughout
4. Tape or otherwise seal all Electrical conduit openings.
5. Provide top rebar at the front garage opening.
6. Recall inspection when completed.
|
|
09/24/2021 | SEPTIC REINSPECTION | RICHARD PRATT | CANCELLED | | 9/24/2021 9:27:37 AM
Entered wrong inspection
|
|
09/24/2021 | SETBACKS | RICHARD PRATT | PASS | | 9/24/2021 9:27:44 AM
Setbacks checked and approved.
|
|
10/01/2021 | FOUNDATION/FOOTINGS | WOODY TOWNSEND | PASS | | 9/30/2021 1:10:26 PM
added to schedule because it was next door to one already on the list
10/1/2021 3:51:23 PM
Contractor was notified to install BMP storm water management mitigation throughout subdivision.
|
|
09/30/2021 | FOUNDATION/FOOTINGS | WOODY TOWNSEND | CANCELLED | eTRAKiT Inspection Request | 9/30/2021 7:58:01 AM
9/30/2021 7:58 AM BLU NELSON CONSTRUCTION
Plumbing has been signed off
Contact Name: BLU NELSON CONSTRUCTION
Site Address: 1338 ESTOM WAY LOT 24
Phone: 5307125516
e-Mail: blunelsonconstruction@gmail.com
9/30/2021 1:07:57 PM
scheduled for fri as B21-2369 was schduled for 10/1 and this is next door.
|
|
10/12/2021 | PRE-SLAB | ADAM KINGSLEY | PASS | eTRAKiT Inspection Request | 10/11/2021 7:04:49 AM
10/11/2021 7:04 AM BLU NELSON CONSTRUCTION
Contact Name: BLU NELSON CONSTRUCTION
Site Address: 1338 ESTOM WAY LOT 24
Phone: 5307125516
e-Mail: blunelsonconstruction@gmail.com
10/12/2021 8:42:26 AM
Inspection via video
|
|
01/11/2022 | SHEARWALL/B.W.P.-EXT | LARRY AKERS | FAIL | eTRAKiT Inspection Request | 1/9/2022 3:27:16 PM
1/9/2022 3:27 PM BLU NELSON CONSTRUCTION
Contact Name: BLU NELSON CONSTRUCTION
Site Address: 1338 ESTOM WAY LOT 24
Phone: 5307125516
e-Mail: blunelsonconstruction@gmail.com
1/11/2022 10:20:06 AM
No plans at site, recall
|
|
01/11/2022 | ROOF NAIL | LARRY AKERS | FAIL | eTRAKiT Inspection Request | 1/9/2022 3:27:16 PM
1/9/2022 3:27 PM BLU NELSON CONSTRUCTION
Contact Name: BLU NELSON CONSTRUCTION
Site Address: 1338 ESTOM WAY LOT 24
Phone: 5307125516
e-Mail: blunelsonconstruction@gmail.com
1/11/2022 10:20:22 AM
No plans at site, recall
|
|
03/09/2022 | STUCCO (LATH) | ADAM KINGSLEY | CANCELLED | eTRAKiT Inspection Request | 3/7/2022 11:18:54 AM
3/7/2022 11:18 AM BLU NELSON CONSTRUCTION
Contact Name: BLU NELSON CONSTRUCTION
Site Address: 1338 ESTOM WAY LOT 24
Phone: 5307125516
e-Mail: blunelsonconstruction@gmail.com
3/9/2022 12:10:37 PM
Wrong permit requested.
|
|
03/09/2022 | 4-WAY ROUGH FRAME | ADAM KINGSLEY | FAIL | Please add Fire inspection | 3/7/2022 11:16:23 AM
3/7/2022 11:16 AM BLU NELSON CONSTRUCTION
Contact Name: BLU NELSON CONSTRUCTION
Site Address: 1338 ESTOM WAY LOT 24
Phone: 5307125516
e-Mail: blunelsonconstruction@gmail.com
3/9/2022 12:10:41 PM
1. Not ready. Building framing not completed at present. Wrong permit requested.
Note: request for lot 27 4way inspection not conducted. Fire sprinkler installation not complete.
|
|
03/24/2022 | SHEARWALL/B.W.P.-EXT | RICHARD PRATT | PASS | eTRAKiT Inspection Request | 3/22/2022 10:46:56 AM
3/22/2022 10:46 AM BLU NELSON CONSTRUCTION
Contact Name: BLU NELSON CONSTRUCTION
Site Address: 1338 ESTOM WAY LOT 24
Phone: 5307125516
e-Mail: blunelsonconstruction@gmail.com
3/24/2022 10:37:07 AM
Interior and exterior shear - Approved
|
|
03/24/2022 | ROOF NAIL | RICHARD PRATT | PASS | eTRAKiT Inspection Request | 3/22/2022 10:46:56 AM
3/22/2022 10:46 AM BLU NELSON CONSTRUCTION
Contact Name: BLU NELSON CONSTRUCTION
Site Address: 1338 ESTOM WAY LOT 24
Phone: 5307125516
e-Mail: blunelsonconstruction@gmail.com
3/24/2022 10:37:11 AM
Truss and roof nail installation - Approved
|
|
05/18/2022 | 4-WAY ROUGH FRAME | RANDALL SMITH | FAIL | eTRAKiT Inspection Request | 5/17/2022 8:15:02 AM
5/17/2022 8:15 AM BLU NELSON CONSTRUCTION
Add fire
Contact Name: BLU NELSON CONSTRUCTION
Site Address: 1338 ESTOM WAY LOT 24
Phone: 5307125516
e-Mail: blunelsonconstruction@gmail.com
5/18/2022 4:53:58 PM
1. Provide full bearing on header in garage. Blue keel
2. Complete nailing and screws on all hardware on pergola's both sides.
3. Replace damaged stud on south garage wall.
4. Tighten down hold down throughout.
5.Missing nut on hold down in dining room next to window.
6. Seal all hvac ducts at the registers.
7.Provide anchor bolt at dining room
8. Mortar all breaks in mud sill
9. Replace damaged stud in coat closet.
10. Red head all inner bottom sills where needed.
11. Provide anchor bolt at front door entry.
12. Replace damaged stud in bedroom 1. More than 16 inches on center.
13. Properly install brackets for securing fire sprinkler piping bedroom 2.
14. Strap condensate pipe in master bedroom.
15. Replace damaged stud in master bedroom corner (more the 16 inches o.c.
16. Provide clearance of range vent to wood as per manufacturer's specifications.
17. Install b vent for gas water heater in garage.
18. Finish nailing A 35 clips through out.
19. Call for reinspection when completed.
|
|
05/18/2022 | STUCCO (LATH) | RANDALL SMITH | CANCELLED | eTRAKiT Inspection Request | 5/17/2022 8:15:02 AM
5/17/2022 8:15 AM BLU NELSON CONSTRUCTION
Add fire
Contact Name: BLU NELSON CONSTRUCTION
Site Address: 1338 ESTOM WAY LOT 24
Phone: 5307125516
e-Mail: blunelsonconstruction@gmail.com
5/18/2022 4:57:50 PM
Not ready
|
|
05/23/2022 | 4-WAY ROUGH FRAME | ADAM KINGSLEY | PASS | eTRAKiT Inspection Request | 5/19/2022 12:01:19 PM
5/19/2022 12:01 PM BLU NELSON CONSTRUCTION
Contact Name: BLU NELSON CONSTRUCTION
Site Address: 1338 ESTOM WAY LOT 24
Phone: 5307125516
e-Mail: blunelsonconstruction@gmail.com
|
|
| TAG ELECTRIC | DSINSPECTION | | VOIDED (SLN 6/21/2022) | 6/19/2022 5:19:24 PM
6/19/2022 5:19 PM BLU NELSON CONSTRUCTION
Contact Name: BLU NELSON CONSTRUCTION
Site Address: 1338 ESTOM WAY LOT 24
Phone: 5307125516
e-Mail: blunelsonconstruction@gmail.com
6/21/2022 8:03:45 AM
Inspection voided by SLN. Most recent remarks follow: eTRAKiT Inspection Request
|
|
| TAG NATURAL GAS | DSINSPECTION | | VOIDED (SLN 6/21/2022) | 6/19/2022 5:19:24 PM
6/19/2022 5:19 PM BLU NELSON CONSTRUCTION
Contact Name: BLU NELSON CONSTRUCTION
Site Address: 1338 ESTOM WAY LOT 24
Phone: 5307125516
e-Mail: blunelsonconstruction@gmail.com
6/21/2022 8:03:52 AM
Inspection voided by SLN. Most recent remarks follow: eTRAKiT Inspection Request
|
|
07/05/2022 | TAG NATURAL GAS | CHRISTOPHER ROBERTS | PASS | eTRAKiT Inspection Request | 7/1/2022 10:38:44 AM
7/1/2022 10:38 AM BLU NELSON CONSTRUCTION
Contact Name: BLU NELSON CONSTRUCTION
Site Address: 1338 ESTOM WAY LOT 24
Phone: 5307125516
e-Mail: blunelsonconstruction@gmail.com
7/5/2022 6:53:16 PM
Gas tag - approved
|
|
07/05/2022 | TAG ELECTRIC | CHRISTOPHER ROBERTS | PASS | eTRAKiT Inspection Request | 7/1/2022 10:38:44 AM
7/1/2022 10:38 AM BLU NELSON CONSTRUCTION
Contact Name: BLU NELSON CONSTRUCTION
Site Address: 1338 ESTOM WAY LOT 24
Phone: 5307125516
e-Mail: blunelsonconstruction@gmail.com
7/5/2022 6:53:24 PM
Electric tag - approved
|
|
07/11/2022 | PGE GAS TAG | CHRISTOPHER ROBERTS | PASS | | 7/11/2022 3:59:57 PM
PGE gas tag - approved
|
|
10/27/2022 | **PERMIT FINAL | WOODY TOWNSEND | FAIL | eTRAKiT Inspection Request | 10/26/2022 7:20:06 AM
10/26/2022 7:20 AM BLU NELSON CONSTRUCTION
Contact Name: BLU NELSON CONSTRUCTION
Site Address: 1338 ESTOM WAY LOT 26
Phone: 5307125516
e-Mail: blunelsonconstruction@gmail.com
10/27/2022 3:23:27 PM
1. Label all breakers in main service. (Complete)
2. Install expansion tank on water piping that is a closed system with backflow preventer or equal.
3. Caulk base of water closets.
4. Install weather resistant listed receptacles at exterior locations.
5. Obtain Cal Fire approvals.
6.Abandon attic access in garage or provide self closing self latching opening.
7. AFCI protect microwave circuit.
8. Provide required combustion air for water heaters. Room volume is 2526 cubic feet. 180k btu' s requires 3600 cf. extend combustion air intake into ventilated attic.
9. Patch fire wall drywall at garage opener switch wiring.
10. Secure range vent to cabinet.
|
|
10/28/2022 | CAL FIRE FINAL INSPE | CHRIS BOYD | PASS | | 10/28/2022 11:14:24 AM
Ok to final
|
|
10/31/2022 | **PERMIT FINAL | WOODY TOWNSEND | PASS | eTRAKiT Inspection Request | 10/27/2022 2:05:17 PM
10/27/2022 2:05 PM BLU NELSON CONSTRUCTION
Contact Name: BLU NELSON CONSTRUCTION
Site Address: 1338 ESTOM WAY LOT 26
Phone: 5307125516
e-Mail: blunelsonconstruction@gmail.com
|
|
10/31/2022 | SEWER DISTRICT FINAL | | PASS | | |
|