Permit No. B21-2292 Permit Type   RESIDENTIAL Site Address   13908 W PARK DR
MAGALIA, CA 95954
Applied   08/02/2021 Applicant   Manuel Ortega
Approved   11/24/2021 Owner   Manuel Ortega
Issued   11/24/2021 Contractor   O/B
Parent Permit No.   Description   REPL SFD (1283) GAR (472) COVD (221) CAMP FIRE
  Notes   none
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

ENV HEALTH RELEASEALANA KONGPASSNew septic system installed9/10/2021 9:01:37 AM Approved 9/10/21 - Septic system installed, final approved by Katty. Ensure tank and leach field meet 5 ft. minimum setback from load-bearing structures.

 04/25/2022SETBACKSRICHARD PRATTPASS4/25/2022 6:23:43 AM rpratt changed Inspection Date/Time from 04/25/2022 08:30 AM to 04/25/2022 2:00 PM 4/25/2022 6:30:22 AM rpratt changed Inspection Date/Time from 04/25/2022 02:00 PM to 04/25/2022 10:00 AM 4/25/2022 12:42:07 PM Setbacks checked and Approved

 04/25/2022PIER/COLUMN FOOTINGSRICHARD PRATTPASS4/25/2022 6:23:46 AM rpratt changed Inspection Date/Time from 04/25/2022 08:30 AM to 04/25/2022 2:00 PM 4/25/2022 6:30:25 AM rpratt changed Inspection Date/Time from 04/25/2022 02:00 PM to 04/25/2022 10:00 AM 4/25/2022 12:42:10 PM Pier footings locations and depth per plan- Approved -

 04/25/2022FOUNDATION/FOOTINGSRICHARD PRATTFAIL4/25/2022 6:23:50 AM rpratt changed Inspection Date/Time from 04/25/2022 08:30 AM to 04/25/2022 2:00 PM 4/25/2022 6:30:28 AM rpratt changed Inspection Date/Time from 04/25/2022 02:00 PM to 04/25/2022 10:00 AM 4/25/2022 12:42:14 PM Provide a 3rd #4 rebar to all pier footings. Verify proper number of anchor bolts are installed at all shear walls. Add rebar at garage grade beam. Recall inspection when completed.

 04/25/2022UFER GROUNDRICHARD PRATTPASS4/25/2022 6:23:39 AM rpratt changed Inspection Date/Time from 04/25/2022 08:30 AM to 04/25/2022 2:00 PM 4/25/2022 6:30:18 AM rpratt changed Inspection Date/Time from 04/25/2022 02:00 PM to 04/25/2022 10:00 AM 4/25/2022 12:42:03 PM Eufer ground - Approved

 04/26/2022FOUNDATION/FOOTINGSSCOTT YOUNGPASS

 05/18/2022UNDERFLOOR PLUMBINGRICHARD PRATTPASSAM REQUEST5/18/2022 3:04:24 PM Underfloor plumbing - on test and Approved

 05/25/2022UNDERFLOOR FRAMINGSCOTT YOUNGFAIL W/RE-INSP FEE5/25/2022 12:51:16 PM Hey My name is Manuel Ortega I would like to reschedule my inspection for Underfloor framing on B21-2292 Address: 13908 W Park Dr, Magalia, CA 95954 -- Adrian M. Ortega AGO Graphics Sacramento California 5/26/2022 6:21:25 AM Showed up at 10:30 waited 15 min, No plans onsite. Left a card with time and date. 5/26/2022 6:23:56 AM Showed up at 10:30 waited 15 min, No plans onsite. Left a card with time and date.

 05/31/2022UNDERFLOOR FRAMINGRANDALL SMITHFAIL916-801-10715/31/2022 12:52:22 PM 1. Provide missing anchor bolts through out. Provide pull test as there are more than 5 missing anchor bolts. 2. Pull all shiners in rim joist and nail as per plans. 3. Complete nailing in post to beam connections. 4. Provide all thread connection to hdu5 at front door. 5.Call for reinspection when completed.

 06/03/2022FOUNDATION/FOOTINGSRICHARD PRATTPASS6/3/2022 6:27:17 AM rpratt changed Inspection Date/Time from 06/03/2022 08:00 AM to 06/03/2022 4:00 PM 6/3/2022 3:38:06 PM Pre pour slab - Approved

 06/03/2022UNDERFLOOR FRAMINGRICHARD PRATTPASS6/3/2022 3:38:11 PM Underfloor framing - all previous correction items completed

 08/23/2022TRUSS ROOFRICHARD PRATTVOID8/23/2022 5:19:49 PM duplicate

 08/24/2022SHEARWALL/B.W.P.-EXTRANDALL SMITHFAIL8/24/2022 2:50:18 PM 1. Tighten HDU's at the garage left side. 2. Provide missing edge nailing 4 inches of at garage both sides. 3. Provide A35 clips as per plan sheet S4 and SN 1 shearwall schedule. 4. Provide cst-16 strapping as per detail SD1-D1. agographics@gmail.com

 08/24/2022ROOF FRAME/SHEATHINGRANDALL SMITHFAIL8/24/2022 2:50:24 PM 1. Provide an approved set of truss calcs on site. 2. Call for reinspection when corrections are completed. Fire rated plywood was NOT used on roof sheathing.

 08/31/2022TRUSS ROOFRANDALL SMITHPASS

 08/31/2022SHEARWALL/B.W.P.-EXTRANDALL SMITHPASS8/31/2022 4:21:53 PM All previous corrections have been completed

 08/31/2022ROOF NAILRANDALL SMITHPASS8/31/2022 4:21:58 PM Passed

 10/06/20224-WAY ROUGH FRAMESCOTT YOUNGFAIL10/10/2022 6:02:54 AM Four way rough was not completed. 1. DWV pipes were dry. 2. Pull all romex away from gang nails and secure. 3. Seal under tub with wire mesh or similar to rodent proof . 4. Seal all cut outs in floor to sub area.

 10/13/20224-WAY ROUGH FRAMESCOTT YOUNGPASS10/19/2022 5:51:27 AM Approved.

 11/10/2022SHEARWALL/B.W.P.-INTRICHARD PRATTPASS11/10/2022 11:16:15 AM Interior shear wall installation - Approved

 02/28/1850PW FINALPWROADSVOIDED (JYM 11/15/2022)11/15/2022 1:21:00 PM Inspection voided by JYM.

 02/01/2023PGE ELECTRIC TAGWOODY TOWNSENDPASS2/1/2023 4:39:06 PM One gfci circuit connected.

 09/11/2023UNDERGROUND GASRANDALL SMITHPASS9/11/2023 3:09:39 PM Ok to cover. Provide a yellow tracer wire 6 inches above the gas pipe.

 10/09/2023CAL FIRE FINAL INSPETROY HANDPASS10/5/2023 2:23:54 PM 1. No address on the building. 2. Need 10-foot clearance around the propane tank. 10/9/2023 3:10:28 PM Both corrections have been made. Ok to final.

 10/11/2023**PERMIT FINALRICHARD PRATTCANCELLED10/11/2023 6:05:34 AM rpratt changed Inspection Date/Time from 10/11/2023 08:00 AM to 10/11/2023 12:30 PM 10/11/2023 7:38:27 AM Fire Sprinkler Permit is expired. Email sent: Good morning, I regret to inform you that the Final inspection that you have requested has been cancelled, due to the Fire Sprinkler Permit having expired. Please contact your fire sprinkler contractor and have them re-new their permit. Only after it has be re-instated, will you be allowed to schedule your building final. Thank you, Rich Pratt

 10/25/2023**PERMIT FINALLARRY AKERSFAILREQUESTS AM10/25/2023 10:19:48 AM 1) all receptacles in garage must be gfci protected 2) kitchen must be gfci and arch fault protected 3) hall bath needs gfci 4) garage receptacle's no gfci protection 5) furnace primary and secondary needs a 90 degree fitting installed 6) both bath fans need to be on a humidistat 7) breaker 5, 11, much be arch fault protected 8) breaker 13 must be gfci protected. 9) call in fire sprinkler permit 10) need hand rail at front entrance.

 11/01/2023**PERMIT FINALRICHARD PRATTPASS11/1/2023 4:44:56 AM rpratt changed Inspection Date/Time from 11/01/2023 08:00 AM to 11/01/2023 08:30 AM 11/1/2023 12:58:58 PM Building Final- Approved