| PW FINAL | PWROADS | | | |
|
09/27/2021 | ENV HEALTH RELEASE | ALANA KONG | PASS | | |
|
05/23/2022 | SETBACKS | RANDALL SMITH | PASS | | 5/23/2022 2:59:29 PM
Passed
|
|
05/23/2022 | GROUNDING/BONDING | RANDALL SMITH | FAIL | | 5/23/2022 2:59:32 PM
1.Clean out footings of rock and debris.
2. Finish installation of anchor bolts.
3. Dig pier footings to 21 inches sq. Install rebar. As per plans.
4.Install eufer ground.
5. Position all hold downs as per manufacturer's listing.
6. Install dobbys where needed.
7. Call for reinspection when completed.
|
|
05/23/2022 | FOUNDATION/FOOTINGS | RANDALL SMITH | FAIL | | 5/23/2022 2:59:35 PM
1.Clean out footings of rock and debris.
2. Finish installation of anchor bolts.
3. Dig pier footings to 21 inches sq. Install rebar. As per plans.
4.Install eufer ground.
5. Position all hold downs as per manufacturer's listing.
6. Install dobbys where needed.
7. Call for reinspection when completed.
|
|
05/31/2022 | PIER/COLUMN FOOTINGS | RANDALL SMITH | PASS | | 5/31/2022 12:52:03 PM
Passed
|
|
05/31/2022 | UFER GROUND | RANDALL SMITH | PASS | | 5/31/2022 12:52:09 PM
Passed
|
|
05/31/2022 | FOUNDATION/FOOTINGS | RANDALL SMITH | PASS | | 5/31/2022 12:52:15 PM
Passed
|
|
06/22/2022 | PRE-SLAB | RICHARD PRATT | PASS | | 6/22/2022 6:47:10 AM
rpratt changed Inspection Date/Time from 06/22/2022 08:00 AM to 06/22/2022 08:30 AM
6/22/2022 11:49:38 AM
Pre pour slab - Approved
|
|
11/09/2022 | TRUSS ROOF | CHRISTOPHER ROBERTS | CANCELLED | | 11/9/2022 6:51:23 AM
croberts changed Inspection Date/Time from 11/09/2022 08:00 AM to 11/09/2022 11:30 AM
|
|
11/09/2022 | ROOF NAIL | CHRISTOPHER ROBERTS | CANCELLED | | 11/9/2022 6:51:29 AM
croberts changed Inspection Date/Time from 11/09/2022 08:00 AM to 11/09/2022 11:30 AM
|
|
11/10/2022 | ROOF NAIL | RICHARD PRATT | FAIL | | 11/10/2022 5:08:46 AM
Rpratt changed Inspection Date/Time from 11/10/2022 08:00 AM to 11/10/2022 12:00 PM
11/10/2022 12:59:03 PM
Re-nail all over-driven fasteners in the roof sheathing.
Remove all shinners and re-nail into the trusses.
Recall inspection when completed
|
|
11/22/2022 | ROOF NAIL | WOODY TOWNSEND | FAIL | 063569-01 MSG! -Msg! Scheduled by IVR. | 11/22/2022 5:38:30 PM
Install cs16 roof strap per SD/10.
|
|
11/29/2022 | UNDERFLOOR FRAMING | RICHARD PRATT | FAIL | | 11/29/2022 6:43:27 PM
1. Get Engineered repair for bottom cord of TJI coming unglued and warped.
2. Provide an Engineered repair for over cut TJI web - master bathroom.
3. Provide 2x6 for cripple wall top plate break support. Northeast corner underfloor.
4. Provide the correct coupler for the anchor bolt to all thread - under master bath/ bedroom.
5. Recall inspection when completed.
|
|
11/29/2022 | ROOF NAIL | RICHARD PRATT | PASS | | 11/29/2022 6:43:32 PM
Roof nail corrections - Approved
|
|
02/17/2023 | PGE ELECTRIC TAG | CHRISTOPHER ROBERTS | PASS | | 2/17/2023 6:08:46 AM
croberts changed Inspection Date/Time from 02/17/2023 08:00 AM to 02/17/2023 10:30 AM
2/17/2023 10:09:19 AM
PGE electric tag - Approved
|
|
03/24/2023 | 4-WAY ROUGH FRAME | CHRISTOPHER ROBERTS | FAIL | plans are inside garage | 3/24/2023 6:26:12 AM
croberts changed Inspection Date/Time from 03/24/2023 08:00 AM to 03/24/2023 10:00 AM
3/24/2023 11:29:00 AM
1. Finish installing doors.
2. Anchor bolt (front of garage) requires a 3"x3" square washer.
3. Provide nail plate protection for gas and PEX lines in garage.
4. Add a couple straps to gas line in laundry room.
5. Nail plate for water line in laundry room.
6. Cover all HVAC registers.
7. Add nail plate protection for sprinkler line next to fireplace.
8. Add nail plate for gas line in kitchen.
9. Repair or replace overnotched bottom sill in bedroom next to kitchen.
10. Secure can light in utility room.
11. Seal off line set exiting the home.
12. Replace bottom plate in entryway from garage that has a floating jack stud.
13. Have plumbing under test at time of inspection.
14. Block in and cover HVAC register in living room.
15. Provide green ground screws for outdoor metal fixtures.
16. Clean up all trash and debris before next inspection.
17. Secure the Tyvek wrap that came undone throughout.
18. Have approved set of Fire Sprinkler plans on-site.
Complete work and call for re-inspection.
|
|
05/15/2023 | 4-WAY ROUGH FRAME | WOODY TOWNSEND | PASS | | |
|
07/31/2023 | PRE-DECK | RAYMOND SANDOVAL | FAIL | eTRAKiT Inspection Request | 7/27/2023 7:57:29 AM
7/27/2023 7:57 AM Raveen Shankar
Contact Name: Raveen Shankar
Site Address: 6230 ODESSA CT
Phone: 4156068643
e-Mail: raveen@sachandro.com
7/31/2023 3:42:54 PM
1.This inspection was meant to be a footing inspection for piers.
The deck has been framed before the piers [see attached pictures]
The method for post supports is unclear as the contractor was not on site and it appears that they want to pour the piers first and then place a sonnet tube on top of the piers and form a cold joint while wet setting the post base hardware into the concrete.
Have the engineer of record address this method.
2. Rebar can not be in contact with earth, maintain required clearances and clean out out footings to 12' depth.
|
|
08/10/2023 | PIER/COLUMN FOOTINGS | RICHARD PRATT | CANCELLED | eTRAKiT Inspection Request | 8/9/2023 9:57:46 AM
8/9/2023 9:57 AM Raveen Shankar
Contact Name: Raveen Shankar
Site Address: 6230 ODESSA CT
Phone: 4156068643
e-Mail: raveen@sachandro.com
8/10/2023 7:59:28 PM
Cancelled by contractor, hung up in traffic coming out of the Bay.
|
|
08/11/2023 | PIER/COLUMN FOOTINGS | RICHARD PRATT | FAIL | eTRAKiT Inspection Request | 8/9/2023 9:27:41 PM
8/9/2023 9:27 PM Raveen Shankar
Contact Name: Raveen Shankar
Site Address: 6230 ODESSA CT
Phone: 4156068643
e-Mail: raveen@sachandro.com
8/11/2023 6:43:01 AM
rpratt changed Inspection Date/Time from 08/11/2023 08:00 AM to 08/11/2023 1:00 PM
8/11/2023 3:58:59 PM
1. Properly form footings and hardware for the rear deck posts.
2. Recall inspection when completed
1. LP gas trench pipe and pressure test - Approved okay to back fill.
2. No gas tag provided until House test is passed.
|
|
08/11/2023 | PGE GAS TAG | RICHARD PRATT | PARTIAL | | 8/11/2023 3:59:51 PM
1. LP gas trench pipe and pressure test - Approved okay to back fill.
2. No gas tag provided until House test is passed.
|
|
| GAS PIPING | DSINSPECTION | | eTRAKiT Inspection Request | 8/10/2023 1:23:16 PM
8/10/2023 1:23 PM Raveen Shankar
Contact Name: Raveen Shankar
Site Address: 6230 ODESSA CT
Phone: 4156068643
e-Mail: raveen@sachandro.com
|
|
| PIER/COLUMN FOOTINGS | DSINSPECTION | | eTRAKiT Inspection Request | 8/11/2023 1:35:01 PM
8/11/2023 1:35 PM Raveen Shankar
Contact Name: Raveen Shankar
Site Address: 6230 ODESSA CT
Phone: 4156068643
e-Mail: raveen@sachandro.com
|
|
08/17/2023 | PIER/COLUMN FOOTINGS | WOODY TOWNSEND | PASS | eTRAKiT Inspection Request | 8/13/2023 11:19:40 AM
8/13/2023 11:19 AM Raveen Shankar
Contact Name: Raveen Shankar
Site Address: 6230 ODESSA CT
Phone: 4156068643
e-Mail: raveen@sachandro.com
|
|
08/17/2023 | GAS TEST | WOODY TOWNSEND | CANCELLED | eTRAKiT Inspection Request | 8/11/2023 1:32:33 PM
8/11/2023 1:32 PM Raveen Shankar
Contact Name: Raveen Shankar
Site Address: 6230 ODESSA CT
Phone: 4156068643
e-Mail: raveen@sachandro.com
8/13/2023 11:18:29 AM
8/13/2023 11:18 AM Raveen Shankar
Contact Name: Raveen Shankar
Site Address: 6230 ODESSA CT
Phone: 4156068643
e-Mail: raveen@sachandro.com
8/17/2023 3:26:06 PM
Not under test.
|
|
09/05/2023 | GAS TEST | RICHARD PRATT | FAIL | eTRAKiT Inspection Request | 8/28/2023 10:28:02 AM
8/28/2023 10:28 AM Raveen Shankar
Contact Name: Raveen Shankar
Site Address: 6230 ODESSA CT
Phone: 4156068643
e-Mail: raveen@sachandro.com
8/29/2023 9:37:15 AM
8/29/2023 9:37 AM Raveen Shankar
Contact Name: Raveen Shankar
Site Address: 6230 ODESSA CT
Phone: 4156068643
e-Mail: raveen@sachandro.com
8/30/2023 7:36:55 AM
8/30/2023 7:36 AM Raveen Shankar
Contact Name: Raveen Shankar
Site Address: 6230 ODESSA CT
Phone: 4156068643
e-Mail: raveen@sachandro.com
9/5/2023 6:09:01 AM
rpratt changed Inspection Date/Time from 09/05/2023 08:00 AM to 09/05/2023 09:30 AM
9/5/2023 11:30:19 AM
House gas lines are not under pressure - pressurize the house gas piping.
Recall inspection when completed.
|
|
09/13/2023 | GAS TEST | RANDALL SMITH | PASS | eTRAKiT Inspection Request | 9/11/2023 7:08:29 PM
9/11/2023 7:08 PM Raveen Shankar
Contact Name: Raveen Shankar
Site Address: 6230 ODESSA CT
Phone: 4156068643
e-Mail: raveen@sachandro.com
|
|
09/13/2023 | PGE GAS TAG | RANDALL SMITH | PARTIAL | | 9/13/2023 2:38:19 PM
Passed gas test for house. Tagged LPG
|
|
12/12/2023 | CAL FIRE FINAL INSPE | TROY HAND | PASS | | 12/12/2023 11:28:51 AM
Met all fire's criteria. Ok to final.
|
|
12/14/2023 | **PERMIT FINAL | SCOTT YOUNG | FAIL | | 12/14/2023 4:19:58 PM
1. Grading required at west side of house , 5%grade?. 10' out =6" drop.
2. A/C condenser required to be secured to pad.
3. Back deck not completed.
4. Insulate water main.
5. Insulate water lines in water heater.
6.exteend the garage step.
7 . Ladder needed at next inspection to access attic.
8. Remove GFCI at refrigerator in kitchen.
9. Dead outlet at kitchen island.
10. No hot water at kitchen sink, bathroom has hot water.
12/18/2023 5:29:16 AM
1. Grading required at west side of house , 5%grade?. 10' out =6" drop.
2. A/C condenser required to be secured to pad.
3. Back deck not completed.
4. Insulate water main.
5. Insulate water lines in water heater.
6.exteend the garage step.
7 . Ladder needed at next inspection to access attic.
8. Remove GFCI at refrigerator in kitchen.
9. Dead outlet at kitchen island.
10. No hot water at kitchen sink, bathroom has hot water.
|
|