| CAL FIRE FINAL INSPE | CHRIS BOYD | | | |
|
06/22/2021 | ENV HEALTH RELEASE | KATTY HERNANDEZ | PASS | | |
|
07/28/2021 | UFER GROUND | ADAM KINGSLEY | PASS | eTRAKiT Inspection Request | 7/27/2021 12:41:29 PM
7/27/2021 12:41 PM WAYLAND CONSTRUCTION INC
Contact Name: WAYLAND CONSTRUCTION INC
Site Address: 3946 STONEY BROOK LN
Phone: 5308989328
e-Mail: WAYLANDCONSTRUCTION@GMAIL.COM
|
|
07/28/2021 | SETBACKS | ADAM KINGSLEY | PASS | eTRAKiT Inspection Request | 7/27/2021 12:40:05 PM
7/27/2021 12:40 PM WAYLAND CONSTRUCTION INC
Contact Name: WAYLAND CONSTRUCTION INC
Site Address: 3946 STONEY BROOK LN
Phone: 5308989328
e-Mail: WAYLANDCONSTRUCTION@GMAIL.COM
|
|
07/28/2021 | FOUNDATION/FOOTINGS | ADAM KINGSLEY | PASS | eTRAKiT Inspection Request | 7/27/2021 12:39:17 PM
7/27/2021 12:39 PM WAYLAND CONSTRUCTION INC
Contact Name: WAYLAND CONSTRUCTION INC
Site Address: 3946 STONEY BROOK LN
Phone: 5308989328
e-Mail: WAYLANDCONSTRUCTION@GMAIL.COM
7/28/2021 1:30:40 PM
Pier footings included
|
|
08/04/2021 | PRE-SLAB | SCOTT YOUNG | PASS | eTRAKiT Inspection Request | 8/3/2021 2:43:44 PM
8/3/2021 2:43 PM WAYLAND CONSTRUCTION INC
Pre Garage Slab inspection
Contact Name: WAYLAND CONSTRUCTION INC
Site Address: 3946 STONEY BROOK LN
Phone: 5308989328
e-Mail: WAYLANDCONSTRUCTION@GMAIL.COM
|
|
08/16/2021 | UNDERFLOOR PLUMBING | WOODY TOWNSEND | PASS | eTRAKiT Inspection Request | 8/11/2021 5:33:37 PM
8/11/2021 5:33 PM WAYLAND CONSTRUCTION INC
Contact Name: WAYLAND CONSTRUCTION INC
Site Address: 3946 STONEY BROOK LN
Phone: 5308989328
e-Mail: WAYLANDCONSTRUCTION@GMAIL.COM
|
|
08/16/2021 | UNDERFLOOR FRAMING | WOODY TOWNSEND | PASS | eTRAKiT Inspection Request | 8/11/2021 5:31:38 PM
8/11/2021 5:31 PM WAYLAND CONSTRUCTION INC
Contact Name: WAYLAND CONSTRUCTION INC
Site Address: 3946 STONEY BROOK LN
Phone: 5308989328
e-Mail: WAYLANDCONSTRUCTION@GMAIL.COM
|
|
10/05/2021 | SHEARWALL/B.W.P.-EXT | ADAM KINGSLEY | PASS | eTRAKiT Inspection Request | 10/4/2021 5:50:06 AM
10/4/2021 5:50 AM WAYLAND CONSTRUCTION INC
Contact Name: WAYLAND CONSTRUCTION INC
Site Address: 3946 STONEY BROOK LN
Phone: 5308989328
e-Mail: WAYLANDCONSTRUCTION@GMAIL.COM
|
|
10/05/2021 | ROOF NAIL | ADAM KINGSLEY | FAIL | eTRAKiT Inspection Request | 10/4/2021 5:48:36 AM
10/4/2021 5:48 AM WAYLAND CONSTRUCTION INC
Contact Name: WAYLAND CONSTRUCTION INC
Site Address: 3946 STONEY BROOK LN
Phone: 5308989328
e-Mail: WAYLANDCONSTRUCTION@GMAIL.COM
10/5/2021 5:42:57 PM
1. Missing complete truss package. Unable to verify required web bracing & multi-ply truss nailing.
2. Provide full width girder truss bearing at entry and laundry areas.
Ok to cover exterior only and follow up at 4way inspection.
|
|
12/16/2021 | STUCCO (LATH) | RICHARD PRATT | PASS | eTRAKiT Inspection Request | 12/15/2021 5:09:50 AM
12/15/2021 5:09 AM WAYLAND CONSTRUCTION INC
Front and Back porch ceilings
Contact Name: WAYLAND CONSTRUCTION INC
Site Address: 3946 STONEY BROOK LN
Phone: 5308989328
e-Mail: WAYLANDCONSTRUCTION@GMAIL.COM
12/16/2021 7:12:51 AM
rpratt changed Inspection Date/Time from 12/16/2021 08:00 AM to 12/16/2021 4:00 PM
12/16/2021 4:16:24 PM
Stucco lath inspection - Approved
|
|
12/27/2021 | 4-WAY ROUGH FRAME | RICHARD PRATT | FAIL | eTRAKiT Inspection Request | 12/22/2021 5:24:26 AM
12/22/2021 5:24 AM WAYLAND CONSTRUCTION INC
Contact Name: WAYLAND CONSTRUCTION INC
Site Address: 3946 STONEY BROOK LN
Phone: 5308989328
e-Mail: WAYLANDCONSTRUCTION@GMAIL.COM
12/27/2021 6:25:12 AM
rpratt changed Inspection Date/Time from 12/27/2021 08:00 AM to 12/27/2021 1:00 PM
12/27/2021 3:09:33 PM
Install gable end bracing per plan - check all throughout.
Adjust fire sprinkler plans to match layout in Kitchen/ Dinning room - 2 installed instead of 3 per plan.
Place Fire Sprinkler system under psi test.
Recall inspection when completed.
|
|
12/29/2021 | 4-WAY ROUGH FRAME | ADAM KINGSLEY | FAIL | eTRAKiT Inspection Request | 12/28/2021 7:37:54 AM
12/28/2021 7:37 AM WAYLAND CONSTRUCTION INC
Re-inspection. Fire sprinklers, Truss bracing.
Contact Name: WAYLAND CONSTRUCTION INC
Site Address: 3946 STONEY BROOK LN
Phone: 5308989328
e-Mail: WAYLANDCONSTRUCTION@GMAIL.COM
12/29/2021 1:23:11 PM
Previous corrections are completed except
RDP 12/27/2021 3:09:33 PM
Install gable end bracing per plan - check all throughout. REINSPECTION: approved plans not available for inspection.
Recall and provide plans.
Ok to insulate. Corrections are to remain exposed for inspection.
|
|
12/30/2021 | 4-WAY ROUGH FRAME | RICHARD PRATT | PASS | eTRAKiT Inspection Request | 12/29/2021 1:30:43 PM
12/29/2021 1:30 PM WAYLAND CONSTRUCTION INC
Contact Name: WAYLAND CONSTRUCTION INC
Site Address: 3946 STONEY BROOK LN
Phone: 5308989328
e-Mail: WAYLANDCONSTRUCTION@GMAIL.COM
12/30/2021 6:18:22 AM
rpratt changed Inspection Date/Time from 12/30/2021 08:00 AM to 12/30/2021 08:30 AM
12/30/2021 10:52:22 AM
All previous correction items completed
|
|
01/19/2022 | GAS TEST | SCOTT YOUNG | PASS | eTRAKiT Inspection Request | 1/18/2022 7:46:24 AM
1/18/2022 7:46 AM WAYLAND CONSTRUCTION INC
Contact Name: WAYLAND CONSTRUCTION INC
Site Address: 3946 STONEY BROOK LN
Phone: 5308989328
e-Mail: WAYLANDCONSTRUCTION@GMAIL.COM
|
|
01/19/2022 | UNDERGROUND GAS | SCOTT YOUNG | PASS | eTRAKiT Inspection Request | 1/18/2022 7:44:48 AM
1/18/2022 7:44 AM WAYLAND CONSTRUCTION INC
Contact Name: WAYLAND CONSTRUCTION INC
Site Address: 3946 STONEY BROOK LN
Phone: 5308989328
e-Mail: WAYLANDCONSTRUCTION@GMAIL.COM
|
|
04/19/2022 | SHOWER PAN/TUB TEST | RANDALL SMITH | PASS | eTRAKiT Inspection Request | 4/14/2022 3:41:00 PM
4/14/2022 3:41 PM WAYLAND CONSTRUCTION INC
Master Shower pan
Contact Name: WAYLAND CONSTRUCTION INC
Site Address: 3946 STONEY BROOK LN
Phone: 5308989328
e-Mail: WAYLANDCONSTRUCTION@GMAIL.COM
4/19/2022 3:25:18 PM
Passed master bath shower an test
|
|
02/28/1850 | NPDES | PWLANDDEV | | VOIDED (ALK 6/10/2022) | 6/10/2022 10:08:01 PM
Inspection voided by ALK.
|
|
06/13/2022 | **PERMIT FINAL | SCOTT YOUNG | CANCELLED | eTRAKiT Inspection Request | 6/8/2022 12:22:24 PM
6/8/2022 12:22 PM WAYLAND CONSTRUCTION INC
Contact Name: WAYLAND CONSTRUCTION INC
Site Address: 3946 STONEY BROOK LN
Phone: 5308989328
e-Mail: WAYLANDCONSTRUCTION@GMAIL.COM
6/13/2022 1:51:45 PM
Inspection cancelled, not ready.
Electrical not finished.
Exhaust fans not installed.
Window missing.
Hers has not been done.
Cal fire sign off required.
|
|
06/14/2022 | **PERMIT FINAL | ADAM KINGSLEY | FAIL | eTRAKiT Inspection Request | 6/8/2022 12:23:08 PM
6/8/2022 12:23 PM WAYLAND CONSTRUCTION INC
Contact Name: WAYLAND CONSTRUCTION INC
Site Address: 3946 STONEY BROOK LN
Phone: 5308989328
e-Mail: WAYLANDCONSTRUCTION@GMAIL.COM
6/14/2022 2:31:02 PM
Previous corrections are completed except:
1. Provide CalFire final clearance.
|
|
06/15/2022 | **PERMIT FINAL | ADAM KINGSLEY | PASS | | 6/15/2022 8:06:11 AM
PREVIOUS CORRECTIONS COMPLETED. VERBAL AUTHOURIZATION PROVIDED FROM FM
|
|