09/05/2021 | FOUNDATION/FOOTINGS | ADAM KINGSLEY | CANCELLED | Cancelled on 9/5/2021 at 2:18 PM | |
|
09/08/2021 | FOUNDATION/FOOTINGS | ADAM KINGSLEY | PASS | 054328-01 - Scheduled by IVR. | |
|
10/05/2021 | UNDERFLOOR FRAMING | RICHARD PRATT | PASS | 054934-01 - Scheduled by IVR. | 10/5/2021 6:24:22 AM
rpratt changed Inspection Date/Time from 10/05/2021 08:00 AM to 10/05/2021 3:30 PM
10/5/2021 5:05:18 PM
Underfloor framing - Approved
|
|
10/18/2021 | PRE-SLAB | ADAM KINGSLEY | PASS | 055264-02 - Scheduled by IVR. | 10/18/2021 3:04:01 PM
Garage slab-approved
|
|
10/15/2021 | PRE-SLAB | SCOTT YOUNG | CANCELLED | Cancelled on 10/15/2021 at 7:46 AM | |
|
01/21/2022 | ROOF NAIL | CURTIS L. JOHNSON | PASS | | 1/24/2022 12:14:46 PM
Roof Nailing approved only. Informed the owner that a plan change would be needed deleting the closet in the garage and adding the space as an extension of the master bath prior to the 4-way inspection.
|
|
03/21/2022 | PGE ELECTRIC TAG | ADAM KINGSLEY | PASS | AM REQUEST | 3/21/2022 12:54:36 PM
200 amp service approved for construction power
|
|
03/21/2022 | SHEARWALL/B.W.P.-EXT | ADAM KINGSLEY | FAIL | | 3/21/2022 12:54:40 PM
1. At bedroom 2 & 3 hold downs required on 3ft brace wall panels . Brace wall panels less than 4ft are required to be alternates in our SZ D
2. Provide H-1 clips on truss/ plate connection per plans.
3. Provide an additional stud at over notched stud by electric panel.
4. Provide retrofit anchors and washers at plate splice within 12 in
5. Outstanding roof nail corrections. Provide plans for updated master bath room expansion.
Ok to proceed and follow up at 4 way inspection
|
|
05/16/2022 | SHEARWALL/B.W.P.-EXT | SCOTT YOUNG | PASS | 059516-01 - Scheduled by IVR. | 5/16/2022 10:30:25 AM
Corrections have been completed
5/17/2022 6:00:33 AM
Corrections have been completed
|
|
05/16/2022 | 4-WAY ROUGH FRAME | SCOTT YOUNG | FAIL | 059514-01 - Scheduled by IVR. | 5/17/2022 6:00:37 AM
1. Interior brace wall panel in hall bath, will be sheeted on both side, tub was already set before Sheetrock was put and thus not being able to complete full shear.
2. Revisions have not been approved by the county for master bath change.
3. Possible revisions required at door entry interior shear,
|
|
05/31/2022 | 4-WAY ROUGH FRAME | SCOTT YOUNG | PASS | 059867-01 MSG! -Msg! Scheduled by IVR. | 6/1/2022 5:57:42 AM
Revisions have been done .
|
|
06/08/2022 | SHEARWALL/B.W.P.-INT | SCOTT YOUNG | PASS | 060106-01 MSG! -Msg! Scheduled by IVR. | 6/8/2022 8:41:35 PM
This inspection was for approx. 8' of interior shear to right of door as you enter .
|
|
06/16/2022 | SHEARWALL/B.W.P.-EXT | RANDALL SMITH | PASS | | 6/13/2022 2:56:27 PM
AM PLEASE
INT. AND EX. BRACEWALL
6/16/2022 3:41:54 PM
Passed
6/16/2022 3:42:29 PM
Passed
6/16/2022 3:44:04 PM
Passed
|
|
07/29/2022 | SHOWER PAN/TUB TEST | CHRISTOPHER ROBERTS | PASS | 061241-01 - Scheduled by IVR. | 7/29/2022 7:11:38 AM
croberts changed Inspection Date/Time from 07/29/2022 08:00 AM to 07/29/2022 1:30 PM
7/29/2022 2:22:27 PM
Shower pan/tub test - approved
|
|
12/23/2022 | GAS PIPING | CHRISTOPHER ROBERTS | PASS | 064327-01 - Scheduled by IVR. | 12/23/2022 6:05:00 AM
croberts changed Inspection Date/Time from 12/23/2022 08:00 AM to 12/23/2022 12:00 PM
12/23/2022 1:55:27 PM
Gas piping - Approved
|
|
12/29/2022 | ENV HEALTH RELEASE | | NOT REQUIRED | | 12/29/2022 11:17:09 AM
Served By TWSD for sewer and water supply.
|
|
01/09/2023 | CAL FIRE FINAL INSPE | TROY HAND | PASS | | 1/9/2023 4:02:27 PM
Met all fire criteria.
|
|
01/10/2023 | **PERMIT FINAL | SCOTT YOUNG | FAIL | 064524-01 - Scheduled by IVR. | 1/9/2023 4:56:19 PM
To meet the requirements of page 2 of your CF1R-PRF-01E, you must obtain the required 3.59kw of Solar. You have a ground mount PV Permit B22-0381, under plan review that Does Not meet those requirements as it is only 3.24kw.
1/10/2023 5:13:37 PM
1. Anti syphon / back flow devices.
2. Front landing required, min. 36"x36"
3. Gas has not been connected to house, tank not set.
4. Insulate water line into water heater.in garage.
5. GFCI required at washing machine and within 6' of sink.
6. Release line for fire sprinkler required to be directed towards the ground.
7. Grading not completed.
8. Front walk and garage entry not finished.
9. Back sliding door is approx 8' above grade. Back deck not completed.
1/11/2023 5:55:55 AM
1. Anti syphon / back flow devices.
2. Front landing required, min. 36"x36"
3. Gas has not been connected to house, tank not set.
4. Insulate water line into water heater.in garage.
5. GFCI required at washing machine and within 6' of sink.
6. Release line for fire sprinkler required to be directed towards the ground.
7. Grading not completed.
8. Front walk and garage entry not finished.
9. Back sliding door is approx 8' above grade. Back deck not completed.
|
|
01/11/2023 | **PERMIT FINAL | SCOTT YOUNG | FAIL | | 1/12/2023 5:44:16 AM
Previous corrections not completed.
To meet the requirements of page 2 of your CFR-PRF-O1E, you must obtain the required 3.59 KW of solar.
You have a ground mount permit , B22-0381, under plan review that does not meet those requirements as it is only 3.24 kw.
This will need to be resolved prior to final of permit B21-0877.
1/12/2023 5:44:37 AM
Previous corrections not completed.
To meet the requirements of page 2 of your CFR-PRF-O1E, you must obtain the required 3.59 KW of solar.
You have a ground mount permit , B22-0381, under plan review that does not meet those requirements as it is only 3.24 kw.
This will need to be resolved prior to final of permit B21-0877.
1/19/2023 9:54:52 AM
ENERGY COMPLIANCE FORM ATTACHED, REVISED TO SHOW 3.18KW REQUIRED.
|
|
07/18/2023 | PW FINAL | PWCONSTRUCTION | PASS | | 7/18/2023 8:24:59 AM
PASS PER R4
|
|
08/07/2023 | **PERMIT FINAL | RANDALL SMITH | PASS | 068151-01 MSG! -Msg! Scheduled by IVR. | 8/7/2023 2:51:24 PM
Permit B22-3081 solar was finaled 8-3-2023. All previous corrections were completed
8/7/2023 3:19:00 PM
See notes below
|
|