05/04/2024
8:11 PM

Butte County
Department of Development Services

Main: 530.552.3700
Automated Inspection Phone Line: 530.538.4365
Online Inspection Scheduling / Payments / Renewals:
ButteCounty.net/DDS

 
Permit No. B21-0436 Permit Type   RESIDENTIAL Site Address   13812 W PARK DR
MAGALIA, CA 95954
Applied   02/18/2021 Applicant   BECKY GILES
Approved   05/21/2021 Owner   BECKY GILES
Issued   05/21/2021 Contractor   OWNER BUILDER
Parent Permit No.   Description   NSF (1564) GAR (710) COV (510) CAMP FIRE
  Notes  
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

 03/29/2021PW FINALPWROADSPASS

 05/26/2021FOUNDATION/FOOTINGSSCOTT YOUNGPASS052403-01 - Scheduled by IVR.5/26/2021 1:20:31 PM Verified and approved: Setbacks Footing and foundation Eupher ground Pier and columns

 06/11/2021UNDERFLOOR FRAMINGSCOTT YOUNGPASS052704-01 - Scheduled by IVR.

 10/11/2021ROOF NAILSCOTT YOUNGPASS055098-03 MSG! -Msg! Scheduled by IVR.

 10/11/2021SHEARWALL/B.W.P.-EXTSCOTT YOUNGPASS055098-02 - Scheduled by IVR.

 10/11/2021SHEAR TRANSFERSCOTT YOUNGPASS055098-01 - Scheduled by IVR.

 10/13/2021TAG ELECTRICSCOTT YOUNGFAIL10/13/2021 11:39:52 AM Open spaces in main panel, place breaker or blank cover. Call for reinspection when ready.

 10/22/2021TAG ELECTRICRICHARD PRATTFAIL10/22/2021 6:28:11 AM rpratt changed Inspection Date/Time from 10/22/2021 08:00 AM to 10/22/2021 09:30 AM 10/22/2021 12:40:00 PM Move MSP out of the framing to allow the door to fully open, now and at final. Label breakers in the MSP. Recall inspection when completed.

 10/27/2021TAG ELECTRICADAM KINGSLEYPASS10/27/2021 2:16:03 PM Construction power approved Previous corrections are completed

 01/14/2022UNDERGROUND WATER PIADAM KINGSLEYPASS1/14/2022 4:15:00 PM Water supply, Meter to SFD-approved

ENV HEALTH RELEASEALANA KONGPASS5/20/2021 4:30:57 PM HOLD FOR SEPTIC, EHS21-0184, FINAL. 1/27/2022 12:51:20 PM FINAL OF EHS21-0184 COMPLETED

 02/03/20224-WAY ROUGH FRAMERICHARD PRATTFAIL057299-01 MSG! -Msg! Scheduled by IVR.2/3/2022 6:11:03 AM rpratt changed Inspection Date/Time from 02/03/2022 to 02/03/2022 2/3/2022 1:42:47 PM Ground all metal boxes - check all, throughout. Complete laundry exhaust duct and terminate to the exterior. Repair bath exhaust duct without smashing at the transition from 3" fan box to 4" duct Provide nail plate protection for NM Cable as marked and required- check throughout. Provide nail plate protection for DWV in master bath - both side of wall. Provide 2 missing receptacles at kitchen counter per plan. Provide the Stamped Approved Fire Sprinkler plans on-site for the inspection. Recall inspection when completed.

 02/07/20224-WAY ROUGH FRAMERICHARD PRATTPASS2/7/2022 6:21:13 AM rpratt changed Inspection Date/Time from 02/07/2022 08:00 AM to 02/07/2022 2:00 PM 2/7/2022 4:37:13 PM 4 way corrections completed

ELECTRICAL FINALRICHARD PRATTVOIDED (RDP 4/11/2022)4/11/2022 6:19:44 AM Inspection voided by RDP. Most recent remarks follow: 058729-02 - Scheduled by IVR.

PLUMBING FINALRICHARD PRATTVOIDED (RDP 4/11/2022)4/11/2022 6:22:30 AM Inspection voided by RDP. Most recent remarks follow: 058729-04 - Scheduled by IVR.

MECHANICAL FINALRICHARD PRATTVOIDED (RDP 4/11/2022)4/11/2022 6:22:47 AM Inspection voided by RDP. Most recent remarks follow: 058729-03 MSG! -Msg! Scheduled by IVR.

FIRE SPRINKLERSRICHARD PRATTVOIDED (RDP 4/11/2022)4/11/2022 6:25:47 AM Inspection voided by RDP. Most recent remarks follow: 058729-01 - Scheduled by IVR.

 04/11/2022**PERMIT FINALRICHARD PRATTFAIL058727-01 - Scheduled by IVR.4/11/2022 3:54:21 PM 1. Provide a pressure relief valve for the water heater and drain to the exterior. 2. Provide a bollard for vehicle protection for the water heater. 3. Provide tamper resistant caps at the condenser. 4. Provide an air gap for the dishwasher. 5. Provide GFCI protection for laundry room receptacles. 6. Provide a humidistat for the shower exhaust fans. 7. Recall inspection when completed. 4/11/2022 4:32:09 PM 1. Provide a pressure relief valve for the water heater and drain to the exterior. 2. Provide a bollard for vehicle protection for the water heater. 3. Provide tamper resistant caps at the condenser. 4. Provide an air gap for the dishwasher. 5. Provide GFCI protection for laundry room receptacles. 6. Provide a humidistat for the shower exhaust fans. 7. Recall inspection when completed.

 04/18/2022**PERMIT FINALRANDALL SMITHPARTIAL4/19/2022 6:40:51 AM Passed all previous corrections written on previous final inspection. Partial as pending approval from Cal Fire.

 04/19/2022CAL FIRE FINAL INSPECHRIS BOYDPASS

 04/19/2022**PERMIT FINALADAM KINGSLEYPASS4/19/2022 5:16:33 PM VERIFIED CALFIRE FINAL CLEARANCE WAS PROVIDED.