10/12/2020 | PW FINAL | PWCONSTRUCTION | PASS | | |
|
11/17/2020 | ENV HEALTH RELEASE | KATTY HERNANDEZ | PASS | SEE NOTES | 11/17/2020 3:28:43 PM
RECEIVED REVISED SITE PLAN. SEE EHS20-0347 AS-BUILT FOR TANK ORIENTATION.
|
|
12/02/2020 | FOUNDATION/FOOTINGS | ADAM KINGSLEY | FAIL | eTRAKiT Inspection Request | 12/1/2020 8:57:28 AM
12/1/2020 8:57 AM INTEGRITY RESTORATION & REMODELING LLC DBA INTEGRITY BUILDERS
Contact Name: INTEGRITY RESTORATION & REMODELING LLC DBA INTEGRITY BUILDERS
Site Address: 13545 WICHITA DR
Phone: 5308723227
e-Mail: office@integrityparadise.com
12/2/2020 3:38:27 PM
1. Remove debris & loose dirt from footings. Footings collapsed and contain trash , debris etc.
2. Foundation not installed per plans. Install Detail 5/4.1 at dwelling entry; Detail 2/4.1 at garage NW corner; Detail 4/4.1 at garage SW corner and Detail 6/4.1 concrete/cripple wall connections per plans or provide written approval from engineer of record or equal.
3. Provide min 3" clearance reinforcement to earth throughout.
Recall inspection corrections addressed.
|
|
12/04/2020 | FOUNDATION/FOOTINGS | RICHARD PRATT | FAIL W/RE-INSP FEE | eTRAKiT Inspection Request | 12/2/2020 9:16:33 PM
12/2/2020 9:16 PM INTEGRITY RESTORATION & REMODELING LLC DBA INTEGRITY BUILDERS
Contact Name: INTEGRITY RESTORATION & REMODELING LLC DBA INTEGRITY BUILDERS
Site Address: 13545 WICHITA DR
Phone: 5308723227
e-Mail: office@integrityparadise.com
12/4/2020 9:21:32 AM
rpratt changed Inspection Date/Time from 12/04/2020 08:00 AM to 12/04/2020 01:00 AM
12/4/2020 9:34:59 AM
rpratt changed Inspection Date/Time from 12/04/2020 01:00 AM to 12/04/2020 1:00 PM
12/4/2020 1:48:56 PM
Complete All Items from Previous Inspection:
ALK 12/2/2020 3:38:27 PM
1. Remove debris & loose dirt from footings. Footings collapsed and contain trash , debris etc.
2. Foundation not installed per plans. Install Detail 5/4.1 at dwelling entry; Detail 2/4.1 at garage NW corner; Detail 4/4.1 at garage SW corner and Detail 6/4.1 concrete/cripple wall connections per plans or provide written approval from engineer of record or equal.
3. Provide min 3%34 clearance reinforcement to earth throughout.
Pay Re-inspection fee prior to Recalling inspection.
|
|
12/14/2020 | FOUNDATION/FOOTINGS | RICHARD PRATT | CANCELLED | eTRAKiT Inspection Request | 12/11/2020 11:58:19 AM
12/11/2020 11:58 AM INTEGRITY RESTORATION & REMODELING LLC DBA INTEGRITY BUILDERS
Contact Name: INTEGRITY RESTORATION & REMODELING LLC DBA INTEGRITY BUILDERS
Site Address: 13545 WICHITA DR
Phone: 5308723227
e-Mail: office@integrityparadise.com
12/14/2020 6:20:20 PM
Cancelled- re-inspection fee not paid and revised plan structural details haven't made it through plan review.
|
|
12/15/2020 | FOUNDATION/FOOTINGS | SCOTT YOUNG | FAIL W/RE-INSP FEE | EARLY AM per CJ Please | 12/15/2020 8:15:07 AM
ALL FEES HAVE BEEN PAID
12/15/2020 4:48:46 PM
Foundation was originally not installed according to approved plans. Install detail 5/4.1 at house entry.
Detail 2/4.1 at garage NW. corner, detail 4/4.1 at garage SW Corner and detail 6/4.1 concrete cripple wall connections per plans or provide written approval from engineer of record.
This was not addressed or corrected from previous inspection, contractor brought out revised set of plans but do not match what has been done. Either build to approved plans specifications ( revised drawings ) or submit revised drawings from engineer of records showing your proposed build. Contractor has removed three lower form boards and wants to expand footing. Detail #2 from revised plans do not match what the contractor has done.
|
|
12/21/2020 | FOUNDATION/FOOTINGS | SCOTT YOUNG | PASS | eTRAKiT Inspection Request | 12/18/2020 12:34:46 PM
12/18/2020 12:34 PM INTEGRITY RESTORATION & REMODELING LLC DBA INTEGRITY BUILDERS
Contact Name: INTEGRITY RESTORATION & REMODELING LLC DBA INTEGRITY BUILDERS
Site Address: 13545 WICHITA DR
Phone: 5308723227
e-Mail: office@integrityparadise.com
12/21/2020 12:10:24 PM
Corrections have been addressed, corrections by engineer done.
12/22/2020 6:47:34 AM
Corrections have been addressed, corrections by engineer done.
|
|
| UNDERFLOOR FRAMING | DSINSPECTION | | eTRAKiT Inspection Request | 12/29/2020 11:38:29 AM
12/29/2020 11:38 AM INTEGRITY RESTORATION & REMODELING LLC
Contact Name: INTEGRITY RESTORATION & REMODELING LLC
Site Address: 13545 WICHITA DR
Phone: 5308723227
e-Mail: office@integrityparadise.com
|
|
12/29/2020 | PRE-SLAB | WOODY TOWNSEND | PASS | | |
|
01/05/2021 | UNDERFLOOR FRAMING | SCOTT YOUNG | PASS | | |
|
01/15/2021 | SHEARWALL/B.W.P.-EXT | ADAM KINGSLEY | FAIL | eTRAKiT Inspection Request | 1/8/2021 12:49:02 PM
1/8/2021 12:49 PM INTEGRITY RESTORATION & REMODELING LLC
Contact Name: INTEGRITY RESTORATION & REMODELING LLC
Site Address: 13545 WICHITA DR
Phone: 5308723227
e-Mail: office@integrityparadise.com
1/15/2021 10:09:03 AM
1. Not ready. Roof sheathing not Installed, assemblies not complete.
|
|
01/15/2021 | ROOF NAIL | ADAM KINGSLEY | FAIL W/RE-INSP FEE | eTRAKiT Inspection Request | 1/8/2021 12:49:02 PM
1/8/2021 12:49 PM INTEGRITY RESTORATION & REMODELING LLC
Contact Name: INTEGRITY RESTORATION & REMODELING LLC
Site Address: 13545 WICHITA DR
Phone: 5308723227
e-Mail: office@integrityparadise.com
1/15/2021 10:09:15 AM
1. Not ready, sheathing not Installed. Reinspection fee added. Pay fee & recall inspection after installation.
|
|
01/19/2021 | SHEARWALL/B.W.P.-EXT | RICHARD PRATT | PASS | eTRAKiT Inspection Request | 1/18/2021 9:47:43 AM
1/18/2021 9:47 AM INTEGRITY RESTORATION & REMODELING LLC
Contact Name: INTEGRITY RESTORATION & REMODELING LLC
Site Address: 13545 WICHITA DR
Phone: 5308723227
e-Mail: office@integrityparadise.com
1/19/2021 6:59:26 AM
rpratt changed Inspection Date/Time from 01/19/2021 08:00 AM to 01/19/2021 12:00 PM
1/19/2021 3:04:43 PM
Exterior shear wall installation- approved - ok to cover
Install missing anchor bolts per plan as needed and required.
Provide Special Inspector letter for Titans installation.
Recall inspection when completed.
|
|
01/19/2021 | ROOF NAIL | RICHARD PRATT | PARTIAL | eTRAKiT Inspection Request | 1/18/2021 9:47:43 AM
1/18/2021 9:47 AM INTEGRITY RESTORATION & REMODELING LLC
Contact Name: INTEGRITY RESTORATION & REMODELING LLC
Site Address: 13545 WICHITA DR
Phone: 5308723227
e-Mail: office@integrityparadise.com
1/19/2021 6:59:35 AM
rpratt changed Inspection Date/Time from 01/19/2021 08:00 AM to 01/19/2021 12:00 PM
1/19/2021 3:04:56 PM
Provide truss calcs for next inspection.
Drag truss nailing and sheathing nailing verified.- ok to cover
|
|
02/26/2021 | 4-WAY ROUGH FRAME | ADAM KINGSLEY | FAIL | eTRAKiT Inspection Request | 2/25/2021 1:59:55 PM
2/25/2021 1:59 PM INTEGRITY RESTORATION & REMODELING LLC
Contact Name: INTEGRITY RESTORATION & REMODELING LLC
Site Address: 13545 WICHITA DR
Phone: 5308723227
e-Mail: office@integrityparadise.com
2/26/2021 12:03:47 PM
1. Fire sprinkler permit corrections: Water supply connection not finished, pipe terminates within wall cavity. System not under test. Complete supply pipe connection & place system under test for reinspection.
2. Provide missing required wall receptacle at master bedroom wall 2' or more. Located right of the door.
3. Missing ducts for all Environmental exhaust fans. Complete duct installation at three locations.
Previous roof nail and shearwall corrections addressed.
Ok to insulate walls & rafter cavities only. Corrections are required to remain exposed for inspection.
|
|
03/02/2021 | UNDERFLOOR PLUMBING | ADAM KINGSLEY | PASS | eTRAKiT Inspection Request | 3/1/2021 11:37:26 AM
3/1/2021 11:37 AM INTEGRITY RESTORATION & REMODELING LLC
Contact Name: INTEGRITY RESTORATION & REMODELING LLC
Site Address: 13545 WICHITA DR
Phone: 5308723227
e-Mail: office@integrityparadise.com
3/2/2021 11:58:08 AM
Verified during previous 4way inspection.
|
|
03/02/2021 | 4-WAY ROUGH FRAME | ADAM KINGSLEY | PASS | eTRAKiT Inspection Request | 3/1/2021 11:37:26 AM
3/1/2021 11:37 AM INTEGRITY RESTORATION & REMODELING LLC
Contact Name: INTEGRITY RESTORATION & REMODELING LLC
Site Address: 13545 WICHITA DR
Phone: 5308723227
e-Mail: office@integrityparadise.com
3/2/2021 11:58:14 AM
Previous corrections are completed
|
|
04/13/2021 | PANEL LABELING | RICHARD PRATT | FAIL | eTRAKiT Inspection Request | 4/12/2021 11:41:29 AM
4/12/2021 11:41 AM INTEGRITY RESTORATION & REMODELING LLC
Contact Name: INTEGRITY RESTORATION & REMODELING LLC
Site Address: 13545 WICHITA DR
Phone: 5308723227
e-Mail: office@integrityparadise.com
4/13/2021 6:45:10 AM
rpratt changed Inspection Date/Time from 04/13/2021 08:00 AM to 04/13/2021 11:00 AM
4/13/2021 4:39:22 PM
Provide access to the ufer ground or 2 ground rods a minimum 6' apart.
Provide a 20a labeled breaker to the gfci receptacle in the garage.
Recall inspection when completed.
|
|
04/15/2021 | PANEL LABELING | RICHARD PRATT | PASS | eTRAKiT Inspection Request | 4/14/2021 11:59:36 AM
4/14/2021 11:59 AM INTEGRITY RESTORATION & REMODELING LLC
PGE tag
Contact Name: INTEGRITY RESTORATION & REMODELING LLC
Site Address: 13545 WICHITA DR
Phone: 5308723227
e-Mail: office@integrityparadise.com
4/15/2021 6:27:43 AM
rpratt changed Inspection Date/Time from 04/15/2021 08:00 AM to 04/15/2021 09:30 AM
4/15/2021 5:12:41 PM
Meter release - approved
|
|
05/14/2021 | GAS PIPING | RICHARD PRATT | PASS | eTRAKiT Inspection Request | 5/12/2021 3:19:43 PM
5/12/2021 3:19 PM INTEGRITY RESTORATION & REMODELING LLC
Contact Name: INTEGRITY RESTORATION & REMODELING LLC
Site Address: 13545 WICHITA DR
Phone: 5308723227
e-Mail: office@integrityparadise.com
5/14/2021 6:33:14 PM
LP gas pipe, trench, tracer wire and both the Residence and piping Pressure Test - Approved
|
|
08/10/2021 | CAL FIRE FINAL INSPE | CHRIS BOYD | PASS | | |
|
08/11/2021 | **PERMIT FINAL | RICHARD PRATT | FAIL | eTRAKiT Inspection Request | 8/9/2021 1:52:07 PM
8/9/2021 1:52 PM INTEGRITY RESTORATION & REMODELING LLC
Contact Name: INTEGRITY RESTORATION & REMODELING LLC
Site Address: 13545 WICHITA DR
Phone: 5308723227
e-Mail: office@integrityparadise.com
8/11/2021 6:46:52 AM
rpratt changed Inspection Date/Time from 08/11/2021 08:00 AM to 08/11/2021 11:30 AM
8/11/2021 5:16:48 PM
1. Obtain CalFire Final Approval.
2. Clean construction debris from under floor area.
3. Replace 30a fuses at the condenser for the Max 25a required.
4. Place elbows on exterior pvc terminations and seal around them at the siding - left elevation.
5. Adjust stairway tread height to be within 3/8" of each other - currently 1" difference. - entry
6. Label Fire Sprinkler Test Valve.
7. Provide a ladder to access the attic.
8. Recall inspection when completed.
|
|
08/26/2021 | **PERMIT FINAL | RICHARD PRATT | PASS | eTRAKiT Inspection Request | 8/25/2021 2:02:27 PM
8/25/2021 2:02 PM INTEGRITY RESTORATION & REMODELING LLC
Contact Name: INTEGRITY RESTORATION & REMODELING LLC
Site Address: 13545 WICHITA DR
Phone: 5308723227
e-Mail: office@integrityparadise.com
8/26/2021 6:36:37 AM
rpratt changed Inspection Date/Time from 08/26/2021 08:00 AM to 08/26/2021 10:30 AM
8/26/2021 10:53:07 AM
Building Final re- inspection - Approved
|
|