Permit No. B20-2440 Permit Type   ACCESSORY DWELLING UNIT Site Address   4254 RANCHO RD
CHICO, CA 95973
Applied   08/19/2020 Applicant   CAROL RUDOLPH
Approved   11/06/2020 Owner   RUDOLPH FAMILY TRUST
Issued   11/06/2020 Contractor   O/B - DAVIS BUILDERS
Parent Permit No.   Description   REPL NSF (1214) GAR (933) OPEN (368) ADU
  Notes  
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

 11/02/2020NPDESPWROADSPASS

 11/06/2020ENV HEALTH RELEASEPAUL THAOPASS11/6/2020 8:49:12 AM Released. Using existing 2 bedroom septic system.

 03/09/2021FOUNDATION/FOOTINGSWOODY TOWNSENDPASS050421-01 MSG! -Msg! Scheduled by IVR.

 03/09/2021UNDER SLAB PLUMBINGWOODY TOWNSENDPASS

 04/01/2021PRE-SLABWOODY TOWNSENDPASS

 04/13/2021PIER/COLUMN FOOTINGSSCOTT YOUNGPASS051376-01 - Scheduled by IVR.

 06/10/2021ROOF NAILADAM KINGSLEYPASS052697-01 - Scheduled by IVR.

 06/10/2021SHEARWALL/B.W.P.-EXTADAM KINGSLEYFAIL052696-01 MSG! -Msg! Scheduled by IVR.6/10/2021 4:04:06 PM 1. Missing DSC2L strap at garage/patio beam. Install or equal per roof plan. 2. Provide additional stud at overnotched exterior wall studs, several locations throughout. Ok to proceed and follow up at 4way.

 06/28/20214-WAY ROUGH FRAMESCOTT YOUNGPASS052982-01 MSG! -Msg! Scheduled by IVR.6/28/2021 2:00:10 PM Also inspected lathe.

 09/08/2021SHOWER PAN/TUB TESTLARRY AKERSPASS054362-01 MSG! -Msg! Scheduled by IVR.9/7/2021 6:32:50 PM Pan is down driveway in rear house.

 10/25/2021**PERMIT FINALRICHARD PRATTFAIL055393-01 - Scheduled by IVR.10/25/2021 7:06:07 AM rpratt changed Inspection Date/Time from 10/25/2021 08:00 AM to 10/25/2021 08:30 AM 10/25/2021 3:42:05 PM 1. Obtain CalFire final approval. 2. Provide an air gap for the dishwasher. 3. Provide a permanent cap on the DWV clean out - right side elevation. 4. Provide vacuum breakers on hose bibs. 5. Provide elbows on the water heater and FAU pan drains over the rear windows. 6. Provide tamper resistant caps for condenser secure electrical conduit. 7. Remove the screen from the drier duct termination and verify there is a back draft damper. 8. Recall inspection when completed.

 10/26/2021CAL FIRE FINAL INSPEJOHN GADDIEPASS10/26/2021 11:14:30 AM OK to Final

 10/26/2021**PERMIT FINALADAM KINGSLEYPASS055407-01 - Scheduled by IVR.10/26/2021 2:39:47 PM Previous corrections are completed