12/29/2022 | UNDERFLOOR FRAMING | LARRY AKERS | FAIL | | 12/29/2022 5:23:19 PM
1) have engineer look at floor and ceiling assemble and design corrections. 4x4 installed under floor joist, ceiling joist has huge deflection, not enough clearance to wood under floor assembly.
2) revise scope of work to include repair of floor joist and roof assembly. Also add to permit if electrical and mechanical work is to be performed. Show on plans insulation, if windows will be change out, or any other work.
|
|
03/14/2023 | UNDERFLOOR FRAMING | LARRY AKERS | FAIL | | 3/14/2023 4:22:47 PM
Have a letter from engineer saying that floor is ok. Work has been covered with no footing or other inspections. Scope of works needs to be changed to show electrical, new windows, insulation. Engineer needs to address the sagging dealing joist and roof. Owner said revisions for roof ceiling assembly is in plan check. Told owner need to talk to engineer and Adam on how to proceed.
3/14/2023 4:29:25 PM
scope of work needs to be revised.
3/15/2023 11:23:05 PM
SEE 3/15/23 CUSTOMER CAME IN CHRONOLOGY
|
|
03/17/2023 | PIER/COLUMN FOOTINGS | CHRISTOPHER ROBERTS | PARTIAL | | 3/17/2023 6:27:11 AM
croberts changed Inspection Date/Time from 03/17/2023 08:00 AM to 03/17/2023 11:00 AM
3/17/2023 11:13:41 AM
The outer footings and middle footing for vertical posts inspected - Approved
Contractor encased the remaining 8x8 pier blocks in concrete prior to inspection.
** contractor will dig out installed footings and call for re-inspection on pier footings for deck.
Complete work and call for re-inspection.
|
|
03/17/2023 | UNDERFLOOR FRAMING | CHRISTOPHER ROBERTS | PASS | | 3/17/2023 11:14:03 AM
Prior corrections have been completed. 4x8 support added to underfloor framing per plans.
|
|
03/24/2023 | ROOF FRAME/SHEATHING | RANDALL SMITH | FAIL | | 3/24/2023 3:48:21 PM
Provide blocking and A35's as per plan.
Provide h-1's at each rafter. Front porch
Replace all rotted roof sheathing.
Complete repairs to inside rafters.
Call for re-inspection before covering any work.
3/24/2023 3:52:45 PM
Provide blocking and A35's as per plan.
Provide h-1's at each rafter. Front porch
Replace all rotted roof sheathing.
Complete repairs to inside rafters.
Call for re-inspection before covering any work.
3/24/2023 3:54:16 PM
Provide blocking and A35's as per plan.
Provide h-1's at each rafter. Front porch
Replace all rotted roof sheathing.
Complete repairs to inside rafters.
Call for re-inspection before covering any work.
|
|
03/24/2023 | PIER/COLUMN FOOTINGS | RANDALL SMITH | PARTIAL | | 3/24/2023 3:48:32 PM
Pier holes missing from last inspection were completed.
3/24/2023 3:52:53 PM
Pier holes missing from last inspection were completed.
3/24/2023 3:54:24 PM
Pier holes missing from last inspection were completed.
|
|
03/27/2023 | ROUGH FRAME | SCOTT YOUNG | FAIL | | 3/27/2023 5:47:02 PM
Not ready for rough frame.
Dry rot repair and roof not finished.
3/28/2023 5:18:57 AM
Not ready for rough frame.
Dry rot repair and roof not finished.
3/28/2023 5:21:23 AM
Not ready for rough frame.
Dry rot repair and roof not finished.
|
|
04/05/2023 | ROOF FRAME/SHEATHING | CHRISTOPHER ROBERTS | PASS | | 4/4/2023 2:43:43 PM
ROOF NAIL AND FIXED DRYROT EAVES ALL AROUND HOUSE
4/5/2023 5:58:54 AM
croberts changed Inspection Date/Time from 04/05/2023 08:00 AM to 04/05/2023 1:30 PM
4/5/2023 3:46:13 PM
Roof sheathing - Approved
|
|
06/13/2023 | 4-WAY ROUGH FRAME | RAYMOND SANDOVAL | FAIL | | 6/13/2023 9:24:18 AM
Not ready for inspection.
Courtesy walk performed.
Complete all framing.
Complete all rough electrical install romex to all electrical boxes and smoke detectors.
Complete all rough mechanical.
Place plumbing DWV on test.
Recall for inspection.
|
|
06/23/2023 | 4-WAY ROUGH FRAME | RAYMOND SANDOVAL | FAIL | | 6/23/2023 8:26:32 AM
1.place DWV on test.
2.Secure water lines,.
3.Seal penetrations in sill plates and top plates..
4.Complete rough electrical, make up grounds for boxes
5.Strap top plate breaks within 24" of each other.
6. Secure all plumbing lines.
7.Attic access to be minimum 22.5x30"
8.Secure romex throughout.
|
|
06/28/2023 | 4-WAY ROUGH FRAME | RAYMOND SANDOVAL | PASS | | |
|
08/09/2023 | ENV HEALTH RELEASE | KATTY HERNANDEZ | PASS | SEE NOTES | 8/9/2023 4:12:47 PM
SEPTIC REPAIR PERMIT RECEIVED FINAL APPROVAL.
|
|
08/17/2023 | **PERMIT FINAL | CHRISTOPHER ROBERTS | FAIL | | 8/17/2023 10:00:22 AM
1. Anti-tip device required for stove.
2. Second GFCI receptacle required in kitchen area.
3. Label all circuits in sub panel.
4. Provide blank for slot in sub-panel.
5. Remove and relocate receptacle behind fridge.
6. Vacancy sensor required in bathroom.
7. Humidistat required in bathroom.
8. Protect romex in attic within 6' of attic access.
9. Provide door for outdoor underfloor access.
10. Strap and protect line set for HVAC behind house.
Complete work and call for re-inspection.
12/21/2023 10:55:20 AM
unpermitted patio cover needs to be completely removed per scope of work.
1/10/2024 12:22:17 PM
PLEASE NOTE: PATIO COVER THE "CARPORT" REFERENCED IN BCE23-00222
|
|