04/29/2024
5:39 AM

Butte County
Department of Development Services

Main: 530.552.3700
Automated Inspection Phone Line: 530.538.4365
Online Inspection Scheduling / Payments / Renewals:
ButteCounty.net/DDS

 
Permit No. B20-0401 Permit Type   NRES NON RESIDENTIAL Site Address   5015 FEATHER RIVER BLVD
OROVILLE, CA 95965
Applied   02/11/2020 Applicant   GLEN QUIGLEY
Approved   04/30/2020 Owner   RICHTER JAKE E
Issued   04/30/2020 Contractor   RICHTER CONSTRUCTION INCORPORATED
Parent Permit No.   Description   OFFICE (2880) PORCH (365)
  Notes  
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

LAND DEV FINALPWLANDDEVNOT REQUIRED

 11/09/2020UNDER SLAB PLUMBINGSCOTT YOUNGFAIL047245-01 - Scheduled by IVR.11/9/2020 7:03:11 PM Pipes not holding pressure.

 11/10/2020UNDER SLAB PLUMBINGSCOTT YOUNGPASS047324-01 - Scheduled by IVR.

 11/13/2020PRE-SLABWOODY TOWNSENDPASS047448-01 - Scheduled by IVR.

 11/13/2020FOUNDATION/FOOTINGSWOODY TOWNSENDPASS

 12/09/2020ROOF NAILSCOTT YOUNGPASS048118-01 MSG! -Msg! Scheduled by IVR.12/10/2020 6:34:09 AM Also inspected interior and exterior shearwall.

 12/23/2020UNDERGROUND PLUMBINGWOODY TOWNSENDPASS048453-01 - Scheduled by IVR.12/23/2020 9:06:57 PM wtownsend changed Inspection Type from CONDENSATN/IND PPNG to UNDERGROUND PLUMBING 12/28/2020 2:00:37 PM Sewer drain and water main approved to backfill.

 01/12/2021STUCCO (LATH)RICHARD PRATTPASS048862-01 MSG! -Msg! Scheduled by IVR.1/12/2021 7:09:09 AM rpratt changed Inspection Date/Time from 01/12/2021 08:30 AM to 01/12/2021 2:30 PM 1/12/2021 2:36:20 PM Stucco lath - Approved

 02/10/20214-WAY ROUGH FRAMERICHARD PRATTFAIL049640-01 MSG! -Msg! Scheduled by IVR.2/10/2021 5:49:28 PM Install anchor bolts within 12" of and no closer than 3" of each plate break - multiple- as marked and required. Provide fire blocking at the wall to stove exhaust vent chase to the attic. Provide nail plate protection for NM Cable - Middle office hallway, North side. Provide backing for toilet paper dispensers in both bathrooms. Provide an offset flange for the water closet prior to final. Water closet centerline to wall clearance 17" - 19". Protect the line set from wearing thru the nail plate - Northeast corner office. Recall inspection when completed.

 02/10/20214-WAY ROUGH FRAMERICHARD PRATTPASS2/10/2021 5:50:44 PM All items completed. (Except offset flange- recheck at final)

 07/06/2021FIRE MARSHAL CLEARANCHRIS BOYDPASS

 07/14/2021**PERMIT FINALRICHARD PRATTFAIL053271-01 - Scheduled by IVR.7/14/2021 6:35:47 AM rpratt changed Inspection Date/Time from 07/14/2021 08:00 AM to 07/14/2021 10:30 AM 7/14/2021 12:12:23 PM Provide tamper resistant caps at both of the condensers. Separate the copper and the sheet metal and properly seal around the line set to prevent insect intrusion. Remove or move the 2 plants from in front of the A/C disconnects to allow proper access. Paint all roof jacks. Repair stucco at front elevation receptacle box. Provide an air gap for the dishwasher. Provide gfci protection for the kitchen receptacles. Provide Site arrival signage for tow from accessible parking. Provide Acceptance Letter for all interior lighting, vacancy sensors and outdoor lighting. Recall inspection when completed.

 07/16/2021ENV HEALTH RELEASEDARREN JONESPASS3/16/2020 8:54:22 AM HOLD RELEASE FOR WATER ISSUES, SEPTIC FINAL AND DESTRUCT 7/16/2021 9:27:55 AM Septic finaled and tanks where removed. Pass

 08/04/2021**PERMIT FINALADAM KINGSLEYFAIL053715-01 - Scheduled by IVR.8/4/2021 11:52:45 AM Previous corrections are completed except 1. Provide NRCA forms (interior & exterior lighting controls and mechanical ventilation).

 08/09/2021**PERMIT FINALADAM KINGSLEYPASS8/9/2021 6:08:56 AM PREVIOUS CORRECTIONS COMPLETED. FORMS ATTACHED.