03/16/2020 | ENV HEALTH RELEASE | PAUL THAO | PASS | | |
|
04/16/2020 | PGE ELECTRIC TAG | ADAM KINGSLEY | PASS | | 4/15/2020 12:17:59 PM
GATE CODE #1. Pause. 149
4/16/2020 6:27:42 AM
akingsley changed Inspection Date/Time from 04/16/2020 08:00 AM to 04/16/2020 3:00 PM
4/16/2020 2:59:43 PM
Construction power approved
|
|
08/07/2020 | FOUNDATION/FOOTINGS | | CANCELLED | eTRAKiT Inspection Request | 8/5/2020 12:20:56 PM
8/5/2020 12:20 PM JIM FAULBAUM CONSTRUCTION
If possible, please schedule for an afternoon time slot and please call when you are on your way. The gate code is #1 149
Contact Name: JIM FAULBAUM CONSTRUCTION
Site Address: 224 SPANISH GARDEN DR
Phone: 5305188148
e-Mail: mail@builderjim.com
|
|
08/11/2020 | FOUNDATION/FOOTINGS | WOODY TOWNSEND | PASS | | 8/11/2020 9:11:41 AM
gate code #1149
8/11/2020 4:54:33 PM
Setbacks,ufer
|
|
09/21/2020 | UNDERFLOOR FRAMING | RICHARD PRATT | PASS | | 9/17/2020 10:44:46 AM
PLEASE CALL JIM FAULBUM AT 530-518-8148 30 MIN PRIOR TO ARRIVING
GATE CODE IS #1149
9/21/2020 5:58:59 AM
PLEASE CALL JIM FAULBUM AT 530-518-8148 30 MIN PRIOR TO ARRIVING
GATE CODE IS #1149
9/21/2020 10:23:44 PM
Underfloor framing- Approved
|
|
09/21/2020 | UNDERFLOOR PLUMBING | RICHARD PRATT | PASS | | 9/22/2020 6:09:33 AM
Underfloor Plumbing with slope and on test - Approved
|
|
11/07/2020 | SHEARWALL/B.W.P.-EXT | ADAM KINGSLEY | FAIL | | 11/7/2020 11:17:49 AM
1. Interior straps installed but not secured full length at all locations. Complete installation or equal.
2. Garage anchor bolts & Holdown devices not installed, existing foundation. Complete installation & provide written approval from engineer of record and special inspection for post concrete installed anchors.
3. 4' shearwall located at south facing wall installed at approximately 2.5' due to window. Provide engineer of record written fix or approval. Design showing 4' SW + 3' window centered on 7.5' wall.
Ok to cover exterior walls only, corrections to remain exposed for inspection.
|
|
11/06/2020 | ROOF NAIL | ADAM KINGSLEY | PARTIAL | | 11/7/2020 11:17:56 AM
1. Approved truss calcs not provided.
2. Entry patio cover not complete.
Roof/drag truss nailing sheathing verified. Remaining roof ok to cover due to weather forecast & follow up at reinspection.
|
|
| FIRE SPRINKLERS | ADAM KINGSLEY | | VOIDED (ALK 1/14/2021) | 1/14/2021 9:15:32 AM
1/14/2021 9:15 AM JIM FAULBAUM CONSTRUCTION
Please call prior to arrival so that I can meet you at the property. Gate Code #1149
Contact Name: JIM FAULBAUM CONSTRUCTION
Site Address: 224 SPANISH GARDEN DR
Phone: 5305188148
e-Mail: mail@builderjim.com
1/14/2021 5:26:08 PM
Inspection voided by ALK. Most recent remarks follow: AM REQUESTED
|
|
01/15/2021 | STUCCO (LATH) | RICHARD PRATT | CANCELLED | eTRAKiT Inspection Request | 1/14/2021 9:15:33 AM
1/14/2021 9:15 AM JIM FAULBAUM CONSTRUCTION
Please call prior to arrival so that I can meet you at the property. Gate Code #1149
Contact Name: JIM FAULBAUM CONSTRUCTION
Site Address: 224 SPANISH GARDEN DR
Phone: 5305188148
e-Mail: mail@builderjim.com
1/15/2021 7:30:14 AM
rpratt changed Inspection Date/Time from 01/15/2021 08:00 AM to 01/15/2021 08:30 AM
1/15/2021 11:51:29 AM
Lath incomplete
1/15/2021 12:06:47 PM
Lath incomplete
1/15/2021 12:57:06 PM
Lath incomplete
1/15/2021 8:37:55 PM
Lath incomplete
|
|
01/15/2021 | 4-WAY ROUGH FRAME | RICHARD PRATT | FAIL | AM REQUESTED | 1/14/2021 9:15:32 AM
1/14/2021 9:15 AM JIM FAULBAUM CONSTRUCTION
Please call prior to arrival so that I can meet you at the property. Gate Code #1149
Contact Name: JIM FAULBAUM CONSTRUCTION
Site Address: 224 SPANISH GARDEN DR
Phone: 5305188148
e-Mail: mail@builderjim.com
1/15/2021 7:30:24 AM
rpratt changed Inspection Date/Time from 01/15/2021 08:00 AM to 01/15/2021 08:30 AM
1/15/2021 11:51:40 AM
Provide fire blocking at the concealed chase - garage, master shower chase, entry double wall.
Provide an H1 at the garage trusses over the vehicle door and jack truss... per 17/SD2
Provide CS16 strapping at beam to top plate break in garage
Provide H1's at trusses in the master bathroom and bathroom
Provide H 2.5 at the girder truss in the garage, hallway,master bedroom
Provide nail plate protection for NM Cable - kitchen
Provide fire blocking at the wall to ceiling - kitchen (RS of range)
Provide mid story straps for DWV- check throughout
Place DWV on top out test.
Provide nail plate protection for DWV - laundry
Strap the unsupported plate break in the living room - near entertainment center.
Provide blocking or equal around over cut penetration in the subfloor to prevent insect or rodent intrusion- bath 2 tub drain
Provide nail plate protection for PEX at master water closet
Recall inspection when completed
1/15/2021 12:06:56 PM
Provide fire blocking at the concealed chase - garage, master shower chase, entry double wall.
Provide an H1 at the garage trusses over the vehicle door and jack truss... per 17/SD2
Provide CS16 strapping at beam to top plate break in garage
Provide H1's at trusses in the master bathroom and bathroom
Provide H 2.5 at the girder truss in the garage, hallway,master bedroom
Provide nail plate protection for NM Cable - kitchen
Provide fire blocking at the wall to ceiling - kitchen (RS of range)
Provide mid story straps for DWV- check throughout
Place DWV on top out test.
Provide nail plate protection for DWV - laundry
Strap the unsupported plate break in the living room - near entertainment center.
Provide blocking or equal around over cut penetration in the subfloor to prevent insect or rodent intrusion- bath 2 tub drain
Provide nail plate protection for PEX at master water closet
Recall inspection when completed
1/15/2021 12:57:19 PM
Provide fire blocking at the concealed chase - garage, master shower chase, entry double wall.
Provide an H1 at the garage trusses over the vehicle door and jack truss... per 17/SD2
Provide CS16 strapping at beam to top plate break in garage
Provide H1's at trusses in the master bathroom and bathroom
Provide H 2.5 at the girder truss in the garage, hallway,master bedroom
Provide nail plate protection for NM Cable - kitchen
Provide fire blocking at the wall to ceiling - kitchen (RS of range)
Provide mid story straps for DWV- check throughout
Place DWV on top out test.
Provide nail plate protection for DWV - laundry
Strap the unsupported plate break in the living room - near entertainment center.
Provide blocking or equal around over cut penetration in the subfloor to prevent insect or rodent intrusion- bath 2 tub drain
Provide nail plate protection for PEX at master water closet
Recall inspection when completed
1/15/2021 8:38:06 PM
Provide fire blocking at the concealed chase - garage, master shower chase, entry double wall.
Provide an H1 at the garage trusses over the vehicle door and jack truss... per 17/SD2
Provide CS16 strapping at beam to top plate break in garage
Provide H1's at trusses in the master bathroom and bathroom
Provide H 2.5 at the girder truss in the garage, hallway,master bedroom
Provide nail plate protection for NM Cable - kitchen
Provide fire blocking at the wall to ceiling - kitchen (RS of range)
Provide mid story straps for DWV- check throughout
Place DWV on top out test.
Provide nail plate protection for DWV - laundry
Strap the unsupported plate break in the living room - near entertainment center.
Provide blocking or equal around over cut penetration in the subfloor to prevent insect or rodent intrusion- bath 2 tub drain
Provide nail plate protection for PEX at master water closet
Recall inspection when completed
|
|
01/19/2021 | STUCCO (LATH) | RICHARD PRATT | PASS | eTRAKiT Inspection Request | 1/18/2021 2:11:22 PM
1/18/2021 2:11 PM JIM FAULBAUM CONSTRUCTION
Contact Name: JIM FAULBAUM CONSTRUCTION
Site Address: 224 SPANISH GARDEN DR
Phone: 5305188148
e-Mail: mail@builderjim.com
1/19/2021 6:58:00 AM
rpratt changed Inspection Date/Time from 01/19/2021 08:00 AM to 01/19/2021 08:30 AM
1/19/2021 12:33:38 PM
Lath inspection - approved
|
|
01/19/2021 | GAS TEST | RICHARD PRATT | PASS | eTRAKiT Inspection Request | 1/18/2021 2:11:22 PM
1/18/2021 2:11 PM JIM FAULBAUM CONSTRUCTION
Contact Name: JIM FAULBAUM CONSTRUCTION
Site Address: 224 SPANISH GARDEN DR
Phone: 5305188148
e-Mail: mail@builderjim.com
1/19/2021 6:58:10 AM
rpratt changed Inspection Date/Time from 01/19/2021 08:00 AM to 01/19/2021 08:30 AM
1/19/2021 12:33:49 PM
House rough gas psi test - approved
|
|
01/19/2021 | FIRE SPRINKLERS | RICHARD PRATT | FAIL | eTRAKiT Inspection Request | 1/18/2021 2:11:22 PM
1/18/2021 2:11 PM JIM FAULBAUM CONSTRUCTION
Contact Name: JIM FAULBAUM CONSTRUCTION
Site Address: 224 SPANISH GARDEN DR
Phone: 5305188148
e-Mail: mail@builderjim.com
1/19/2021 6:58:19 AM
rpratt changed Inspection Date/Time from 01/19/2021 08:00 AM to 01/19/2021 08:30 AM
1/19/2021 12:34:00 PM
Revise plans and re-submit to Building Dept for plan review or install missing sprinkler heads (2) in the living room and (1) in the master bathroom.
Recall inspection when completed.
|
|
01/19/2021 | 4-WAY ROUGH FRAME | RICHARD PRATT | PASS | eTRAKiT Inspection Request | 1/18/2021 2:11:21 PM
1/18/2021 2:11 PM JIM FAULBAUM CONSTRUCTION
Contact Name: JIM FAULBAUM CONSTRUCTION
Site Address: 224 SPANISH GARDEN DR
Phone: 5305188148
e-Mail: mail@builderjim.com
1/19/2021 6:58:29 AM
rpratt changed Inspection Date/Time from 01/19/2021 08:00 AM to 01/19/2021 08:30 AM
1/19/2021 12:34:09 PM
Rough frame and trades - approved
|
|
02/08/2021 | PGE ELECTRIC TAG | SCOTT YOUNG | PASS | | 2/5/2021 2:32:45 PM
GATE CODE IS #1149
|
|
04/13/2021 | STUCCO (SCRATCH) | SCOTT YOUNG | NOT REQUIRED | | |
|
05/25/2021 | SHOWER PAN/TUB TEST | WOODY TOWNSEND | PASS | | 5/24/2021 11:49:56 AM
GATE CODE IS #1149
|
|
09/09/2021 | PROGRESS INSPECTION | SCOTT YOUNG | CANCELLED | GATE CODE #1149 | 9/8/2021 1:32:28 PM
AM REQUEST
|
|
09/09/2021 | GAS PIPING | SCOTT YOUNG | PASS | GATE CODE #1149 | 9/8/2021 1:32:06 PM
AM REQUEST
|
|
09/15/2021 | CAL FIRE FINAL INSPE | CHRIS BOYD | PASS | | 9/15/2021 10:29:02 AM
No address posted, contacted Jim and asked to post and recall.
9/23/2021 9:11:54 AM
Ok to final.
|
|
09/24/2021 | UNDERFLOOR PLUMBING | DSINSPECTION | VOID | | 9/17/2020 10:45:16 AM
PLEASE CALL JIM FAULBUM AT 530-518-8148 30 MIN PRIOR TO ARRIVING
GATE CODE IS #1149
9/24/2021 5:47:29 AM
VOIDED DUPLICATE INSPECTION
|
|
09/24/2021 | NPDES | ADAM KINGSLEY | PASS | | |
|
09/24/2021 | **PERMIT FINAL | ADAM KINGSLEY | PASS | | 9/23/2021 8:32:40 AM
EARLY AM PLEASE
|
|