| ENV HEALTH RELEASE | YVETTE CASTANON | PASS | | 12/17/2019 9:28:46 AM
Maintain min of 5 ft from structures
|
|
02/28/1850 | NPDES | PWROADS | | VOIDED (SLN 12/17/2019) | 12/17/2019 1:57:29 PM
Inspection voided by SLN.
|
|
06/02/2020 | CONTINUITY TEST | ADAM KINGSLEY | VOID | | 6/2/2020 10:44:36 AM
Added to wrong permit
|
|
06/02/2020 | FOUNDATION/FOOTINGS | ADAM KINGSLEY | PASS | eTRAKiT Inspection Request | 6/1/2020 9:11:20 AM
6/1/2020 9:11 AM RED LINE INSTALLATIONS INC
Contact Name: RED LINE INSTALLATIONS INC
Site Address: 6287 BREVARD CIR
Phone: 5308916719
e-Mail: PERMIT@REDLINEINSTALL.COM
6/2/2020 11:04:12 AM
Setbacks, eufer ground & monolithic preslab included
|
|
06/15/2020 | SHEARWALL/B.W.P.-EXT | ADAM KINGSLEY | PARTIAL | eTRAKiT Inspection Request | 6/11/2020 12:56:54 PM
6/11/2020 12:56 PM RED LINE INSTALLATIONS INC
Contact Name: RED LINE INSTALLATIONS INC
Site Address: 6287 BREVARD CIR
Phone: 5308916719
e-Mail: PERMIT@REDLINEINSTALL.COM
6/15/2020 3:16:24 PM
1. Roof not installed. Complete installation.
2. Missing HD & anchor bolts at Shearwall right of vehicle door. Install per plans.
3. Missing anchor bolts several locations. Provide between 7bar diameter & 12" from end of sill.
Exterior nailing verified ok to cover exterior only.
|
|
06/15/2020 | SHEARWALL/B.W.P.-INT | ADAM KINGSLEY | FAIL | | 6/15/2020 3:16:31 PM
1. Studs notched exceeds 25% width at three locations. Provide full height double stud or equal.
2. Foundation stemwall out of level, Mud sill leveled with shims between sill & foundation. Provide engineer of record written fix or approval.
|
|
| ROOF NAIL | DSINSPECTION | | eTRAKiT Inspection Request | 6/25/2020 11:33:30 AM
6/25/2020 11:33 AM RED LINE INSTALLATIONS INC
Contact Name: RED LINE INSTALLATIONS INC
Site Address: 6287 BREVARD CIR
Phone: 5308916719
e-Mail: PERMIT@REDLINEINSTALL.COM
|
|
06/29/2020 | ROOF NAIL | RICHARD PRATT | PASS | eTRAKiT Inspection Request | 6/25/2020 11:38:23 AM
6/25/2020 11:38 AM RED LINE INSTALLATIONS INC
Contact Name: RED LINE INSTALLATIONS INC
Site Address: 6287 BREVARD CIR
Phone: 5308916719
e-Mail: PERMIT@REDLINEINSTALL.COM
6/29/2020 6:22:47 AM
rpratt changed Inspection Date/Time from 06/29/2020 08:00 AM to 06/29/2020 11:00 AM
6/29/2020 3:04:26 PM
Roof nail - approved - ok to cover
|
|
06/29/2020 | SHEARWALL/B.W.P.-EXT | RICHARD PRATT | PASS | eTRAKiT Inspection Request | 6/25/2020 11:36:18 AM
6/25/2020 11:36 AM RED LINE INSTALLATIONS INC
Contact Name: RED LINE INSTALLATIONS INC
Site Address: 6287 BREVARD CIR
Phone: 5308916719
e-Mail: PERMIT@REDLINEINSTALL.COM
6/29/2020 6:28:13 AM
rpratt changed Inspection Date/Time from 06/29/2020 08:00 AM to 06/29/2020 11:00 AM
6/29/2020 3:04:33 PM
Ext shear nail inspection completed - approved
|
|
06/29/2020 | PROGRESS INSPECTION | RICHARD PRATT | CANCELLED | eTRAKiT Inspection Request | 6/25/2020 11:36:18 AM
6/25/2020 11:36 AM RED LINE INSTALLATIONS INC
Contact Name: RED LINE INSTALLATIONS INC
Site Address: 6287 BREVARD CIR
Phone: 5308916719
e-Mail: PERMIT@REDLINEINSTALL.COM
6/29/2020 6:28:20 AM
rpratt changed Inspection Date/Time from 06/29/2020 08:00 AM to 06/29/2020 11:00 AM
|
|
07/14/2020 | ROUGH FRAME | RICHARD PRATT | PASS | | 7/14/2020 6:42:50 AM
rpratt changed Inspection Date/Time from 07/14/2020 08:00 AM to 07/14/2020 10:30 AM
7/14/2020 6:54:05 AM
rpratt changed Inspection Date/Time from 07/14/2020 10:30 AM to 07/14/2020 11:00 AM
7/14/2020 12:04:24 PM
Rough frame approved.
|
|
07/14/2020 | ROUGH ELECTRICAL | RICHARD PRATT | PASS | | 7/14/2020 6:42:56 AM
rpratt changed Inspection Date/Time from 07/14/2020 08:00 AM to 07/14/2020 11:00 AM
7/14/2020 12:04:32 PM
Rough Electrical Approved
|
|
07/20/2020 | TAG ELECTRIC | SCOTT YOUNG | PASS | eTRAKiT Inspection Request | 7/16/2020 2:15:31 PM
7/16/2020 2:15 PM RED LINE INSTALLATIONS INC
Contact Name: RED LINE INSTALLATIONS INC
Site Address: 6287 BREVARD CIR
Phone: 5308916719
e-Mail: PERMIT@REDLINEINSTALL.COM
|
|
09/16/2020 | CAL FIRE FINAL INSPE | CHRIS BOYD | PASS | | |
|
09/17/2020 | **PERMIT FINAL | RICHARD PRATT | PASS | 045644-01 - Scheduled by IVR. | 9/17/2020 6:54:29 AM
rpratt changed Inspection Date/Time from 09/17/2020 08:00 AM to 09/17/2020 12:30 PM
9/17/2020 6:56:01 AM
rpratt changed Inspection Date/Time from 09/17/2020 08:00 AM to 09/17/2020 12:30 PM
9/17/2020 6:23:09 PM
Building Final - Approved
|
|