| NPDES | QUENTIN CARTER | | | |
|
05/14/2020 | ENV HEALTH RELEASE | KATTY HERNANDEZ | PASS | SEE NOTES | 5/14/2020 10:36:59 AM
SEPTIC EXPANSION PERMIT, EHS19-0432, RECEIVED FINAL APPROVAL.
|
|
06/04/2020 | 433A | PERMIT CENTER | PASS | ALL DOCS RECEIVED | 6/2/2020 3:35:41 PM
GRANT DEED AND MCO RECEIVED
6/4/2020 1:24:47 PM
HCD CHECK IN SAFE
|
|
06/22/2020 | SETBACKS | ADAM KINGSLEY | PASS | eTRAKiT Inspection Request | 6/18/2020 3:33:49 PM
6/18/2020 3:33 PM RED LINE INSTALLATIONS INC
Contact Name: RED LINE INSTALLATIONS INC
Site Address: 13729 ENDICOT CIR
Phone: 5308916719
e-Mail: PERMIT@REDLINEINSTALL.COM
|
|
06/22/2020 | CONTINUITY TEST | ADAM KINGSLEY | PASS | eTRAKiT Inspection Request | 6/18/2020 3:33:49 PM
6/18/2020 3:33 PM RED LINE INSTALLATIONS INC
Contact Name: RED LINE INSTALLATIONS INC
Site Address: 13729 ENDICOT CIR
Phone: 5308916719
e-Mail: PERMIT@REDLINEINSTALL.COM
|
|
06/22/2020 | BOLTS | ADAM KINGSLEY | NOT REQUIRED | eTRAKiT Inspection Request | 6/18/2020 3:33:48 PM
6/18/2020 3:33 PM RED LINE INSTALLATIONS INC
Contact Name: RED LINE INSTALLATIONS INC
Site Address: 13729 ENDICOT CIR
Phone: 5308916719
e-Mail: PERMIT@REDLINEINSTALL.COM
6/22/2020 2:53:22 PM
Not required by AHJ
|
|
06/22/2020 | BLOCKING/UNDERPINNIN | ADAM KINGSLEY | FAIL | eTRAKiT Inspection Request | 6/18/2020 3:33:48 PM
6/18/2020 3:33 PM RED LINE INSTALLATIONS INC
Contact Name: RED LINE INSTALLATIONS INC
Site Address: 13729 ENDICOT CIR
Phone: 5308916719
e-Mail: PERMIT@REDLINEINSTALL.COM
6/22/2020 2:53:29 PM
1. Marriage line piers & pads undersized at two locations. Provide doubled piers w/ 32"sq x 8"deep concrete footings per plans at 8800# pier loads or equal.
|
|
06/30/2020 | PGE ELECTRIC TAG | RICHARD PRATT | FAIL | eTRAKiT Inspection Request | 6/29/2020 7:20:25 AM
6/29/2020 7:20 AM RED LINE INSTALLATIONS INC
Contact Name: RED LINE INSTALLATIONS INC
Site Address: 13729 ENDICOT CIR
Phone: 5308916719
e-Mail: PERMIT@REDLINEINSTALL.COM
6/30/2020 7:05:52 AM
rpratt changed Inspection Date/Time from 06/30/2020 08:00 AM to 06/30/2020 1:30 PM
6/30/2020 8:04:49 AM
rpratt changed Inspection Date/Time from 06/30/2020 08:00 AM to 06/30/2020 1:30 PM
6/30/2020 6:08:32 PM
Provide a gfci receptacle in a weather resistant box wired to a 20a breaker, labeled "Temp".
Recall inspection when completed
|
|
07/02/2020 | PGE ELECTRIC TAG | ADAM KINGSLEY | PASS | eTRAKiT Inspection Request | 7/1/2020 7:13:53 AM
7/1/2020 7:13 AM RED LINE INSTALLATIONS INC
Contact Name: RED LINE INSTALLATIONS INC
Site Address: 13729 ENDICOT CIR
Phone: 5308916719
e-Mail: PERMIT@REDLINEINSTALL.COM
|
|
07/07/2020 | BLOCKING/UNDERPINNIN | SCOTT YOUNG | PASS | eTRAKiT Inspection Request | 7/6/2020 1:54:50 PM
7/6/2020 1:54 PM RED LINE INSTALLATIONS INC
Contact Name: RED LINE INSTALLATIONS INC
Site Address: 13729 ENDICOT CIR
Phone: 5308916719
e-Mail: PERMIT@REDLINEINSTALL.COM
7/7/2020 6:55:13 PM
Corrections addressed.
7/7/2020 7:15:41 PM
Corrections addressed.
7/8/2020 6:34:56 AM
Corrections addressed.
|
|
07/14/2020 | UNDERGROUND WATER PI | RICHARD PRATT | PARTIAL | eTRAKiT Inspection Request | 7/13/2020 1:34:35 PM
7/13/2020 1:34 PM RED LINE INSTALLATIONS INC
Open Trench - waterline
Contact Name: RED LINE INSTALLATIONS INC
Site Address: 13729 ENDICOT CIR
Phone: 5308916719
e-Mail: PERMIT@REDLINEINSTALL.COM
7/14/2020 6:42:37 AM
rpratt changed Inspection Date/Time from 07/14/2020 08:00 AM to 07/14/2020 09:30 AM
7/14/2020 12:04:18 PM
Provide a CalFire approved Address maker out front at the street.
Water Pipe Pressure test passed.
Remove gravel and rocks support with clean fill or sand.
Recall inspection when completed.
|
|
07/29/2020 | CAL FIRE FINAL INSPE | CHRIS BOYD | PASS | | |
|
08/03/2020 | **PERMIT FINAL | RICHARD PRATT | FAIL | eTRAKiT Inspection Request | 7/27/2020 1:46:11 PM
7/27/2020 1:46 PM RED LINE INSTALLATIONS INC
Contact Name: RED LINE INSTALLATIONS INC
Site Address: 13729 ENDICOT CIR
Phone: 5308916719
e-Mail: PERMIT@REDLINEINSTALL.COM
7/31/2020 5:55:22 AM
rpratt changed Inspection Date/Time from 07/31/2020 08:00 AM to 07/31/2020 3:30 PM
7/31/2020 7:30:44 PM
Terminate the psi relief valve drain to the exterior of the building.
Obtain the Water District Final Approval.
Recall inspection when completed.
8/3/2020 5:49:09 AM
Terminate the psi relief valve drain to the exterior of the building.
Obtain the Water District Final Approval.
Recall inspection when completed.
|
|
| WATER DISTRICT FINAL | DSINSPECTION | PASS | | |
|
08/05/2020 | **PERMIT FINAL | RICHARD PRATT | PASS | eTRAKiT Inspection Request | 8/3/2020 3:33:03 PM
8/3/2020 3:33 PM RED LINE INSTALLATIONS INC
Contact Name: RED LINE INSTALLATIONS INC
Site Address: 13729 ENDICOT CIR
Phone: 5308916719
e-Mail: PERMIT@REDLINEINSTALL.COM
8/5/2020 5:43:48 AM
rpratt changed Inspection Date/Time from 08/05/2020 08:00 AM to 08/05/2020 1:00 PM
8/5/2020 3:53:04 PM
Building Final Re-inspection- Approved
|
|