01/07/2020 | ENV HEALTH RELEASE | PAUL THAO | PASS | | 1/7/2020 10:10:34 AM
Septic system setback met, pass.
|
|
07/22/2020 | PIER/COLUMN FOOTINGS | WOODY TOWNSEND | PASS | Pier/Column Footings IVR #122 | 7/21/2020 6:25:58 AM
7/21/2020 6:25 AM BRUCARDI CONSTRUCTION
#3 Post Column Footings
AM/Morning Inspection if we are able to request....
Call/Text Bruce @ 530-519-9251 when on your way if possible?
If Driveway gate is closed please use walk through gate to the right. Project is in the rear of the (E) home.
Contact Name: BRUCARDI CONSTRUCTION
Site Address: 261 WILD ROSE CIR
Phone: 5305199251
e-Mail: brucardi@aol.com
|
|
08/14/2020 | FOUNDATION/FOOTINGS | WOODY TOWNSEND | PASS | Addition Footings & Under slab plumbing | 8/13/2020 9:53:12 AM
8/13/2020 9:53 AM BRUCARDI CONSTRUCTION
Contact Name: BRUCARDI CONSTRUCTION
Site Address: 261 WILD ROSE CIR
Phone: 5305199251
e-Mail: brucardi@aol.com
|
|
08/14/2020 | UNDER SLAB PLUMBING | WOODY TOWNSEND | PASS | | |
|
08/18/2020 | PRE-SLAB | SCOTT YOUNG | PASS | AM if possible? | 8/14/2020 9:14:03 AM
8/14/2020 9:14 AM BRUCARDI CONSTRUCTION
Contact Name: BRUCARDI CONSTRUCTION
Site Address: 261 WILD ROSE CIR
Phone: 5305199251
e-Mail: brucardi@aol.com
8/14/2020 3:02:05 PM
8/14/2020 3:02 PM BRUCARDI CONSTRUCTION
Contact Name: BRUCARDI CONSTRUCTION
Site Address: 261 WILD ROSE CIR
Phone: 5305199251
e-Mail: brucardi@aol.com
|
|
10/07/2020 | ROOF NAIL | ADAM KINGSLEY | PASS | IVR 129, 135, 153Possible IVR 134 | 10/6/2020 10:33:00 AM
10/6/2020 10:33 AM BRUCARDI CONSTRUCTION
#2 (N) hold downs are behind (N) Interior shearwall. Need Hold downs inspected for interior shearwall to be nailed off?
Contact Name: BRUCARDI CONSTRUCTION
Site Address: 261 WILD ROSE CIR
Phone: 5305199251
e-Mail: brucardi@aol.com
10/7/2020 4:24:44 PM
Inspector SVY changed the inspection assignment from SVY to ALK
|
|
10/07/2020 | SHEARWALL/B.W.P.-EXT | ADAM KINGSLEY | PASS | | |
|
10/07/2020 | SHEARWALL/B.W.P.-INT | ADAM KINGSLEY | PARTIAL | | 10/7/2020 6:18:22 PM
Framing & HD devices verified, ok to close up interior shearwalls only.
|
|
11/05/2020 | 4-WAY ROUGH FRAME | WOODY TOWNSEND | PASS | Adam Kingsley did the rough framing insp | 11/4/2020 6:29:58 AM
11/4/2020 6:29 AM BRUCARDI CONSTRUCTION
Rough framing inspection was done by Adam Kingsley. We had to cover up holddowns & some Plumbing with the Shearwalls, so he inspected it along with the last inspection of Shearwall & Roof Nailing.
IVR#''s
#406
#316
#208
#403 & #404
Possible #408
Contact Name: BRUCARDI CONSTRUCTION
Site Address: 261 WILD ROSE CIR
Phone: 5305199251
e-Mail: brucardi@aol.com
11/5/2020 5:33:56 PM
Underground and house gas pipe and test approved.
|
|
11/05/2020 | SHOWER PAN/TUB TEST | WOODY TOWNSEND | PASS | | |
|
11/17/2020 | STUCCO (LATH) | SCOTT YOUNG | PASS | Morning/AM Inspection if possible? | 11/12/2020 1:47:03 AM
11/12/2020 1:46 AM BRUCARDI CONSTRUCTION
Contact Name: BRUCARDI CONSTRUCTION
Site Address: 261 WILD ROSE CIR
Phone: 5305199251
e-Mail: brucardi@aol.com
|
|
04/13/2021 | **PERMIT FINAL | SCOTT YOUNG | PASS | | |
|