| NPDES | QUENTIN CARTER | | | |
|
| ENV HEALTH RELEASE | DARREN JONES | PASS | ok to rls 6/20/2019 | |
|
09/16/2019 | FOUNDATION/FOOTINGS | WOODY TOWNSEND | FAIL | eTRAKiT Inspection Request | 9/12/2019 1:18:05 PM
9/12/2019 1:18 PM PHOENIX ENERGY FULFILLMENT INC
Contact Name: PHOENIX ENERGY FULFILLMENT INC
Site Address: 15756 FITZGERALD CT
Phone: 5309179956
e-Mail: pfeaster@phoenixsolarinc.com
9/16/2019 5:21:36 PM
Provide approved plans for 18 16" x 36 " piers.
|
|
09/24/2019 | **PERMIT FINAL | ADAM KINGSLEY | VOID | eTRAKiT Inspection Request | 9/18/2019 3:58:29 PM
9/18/2019 3:58 PM PHOENIX ENERGY FULFILLMENT INC
Contact Name: PHOENIX ENERGY FULFILLMENT INC
Site Address: 15756 FITZGERALD CT
Phone: 5309179956
e-Mail: OPERATIONS@phoenixsolarinc.com
9/24/2019 1:45:14 PM
Wrong inspection request. Added footings
|
|
09/24/2019 | FOUNDATION/FOOTINGS | ADAM KINGSLEY | PASS | | 9/24/2019 1:45:26 PM
Previous corrections are completed. Setbacks included
|
|
10/22/2019 | **PERMIT FINAL | PHILLIP MYERS | FAIL | eTRAKiT Inspection Request | 10/21/2019 9:59:52 AM
10/21/2019 9:59 AM PHOENIX ENERGY FULFILLMENT INC
Contact Name: PHOENIX ENERGY FULFILLMENT INC
Site Address: 15756 FITZGERALD CT
Phone: 5309179956
e-Mail: OPERATIONS@phoenixsolarinc.com
10/22/2019 12:30:25 PM
Plans do not reflect actual site conditions. Please have plans show what they are feeding...
10/24/2019 4:28:06 PM
The plans do not reflect actual site conditions... The line diagram shows the sub panel and meter to be in the same location. This is not the actual condition. The main service panel and meter is on the detached garage. The plans as drawn show the subpanel to be final point of connection what are the panels feeding.
1/13/2020 4:57:34 PM
Plan Change is required: Plans show feeder conductors from Ground Mount Solar Photovoltaic Array to main service panel at the detached garage... The Actual Site conditions are that the feeders from solar array, are feeding underground to the house then, under house to sub panel in the dwelling unit. Please change plans to reflect actual site conditions. Also please specify how this is back feeding the Main service panel.
|
|
| **PERMIT FINAL | DSINSPECTION | | eTRAKiT Inspection Request | 11/20/2019 10:03:42 AM
11/20/2019 10:03 AM PHOENIX ENERGY FULFILLMENT INC
Contact Name: PHOENIX ENERGY FULFILLMENT INC
Site Address: 15756 FITZGERALD CT
Phone: 5309179956
e-Mail: OPERATIONS@phoenixsolarinc.com
|
|
02/18/2020 | **PERMIT FINAL | WOODY TOWNSEND | FAIL W/RE-INSP FEE | eTRAKiT Inspection Request | 2/14/2020 11:22:42 AM
2/14/2020 11:22 AM PHOENIX ENERGY FULFILLMENT INC DBA PHOENIX SOLAR ENERGY
Contact Name: PHOENIX ENERGY FULFILLMENT INC DBA PHOENIX SOLAR ENERGY
Site Address: 15756 FITZGERALD CT
Phone: 5309179956
e-Mail: OPERATIONS@phoenixsolarinc.com
2/18/2020 11:26:34 AM
1. Provide access to sub panel inside house.
2. Revised line diagram to reflect as built. 125 amp breaker from main to house on revised plans is 175 amp and sub panel and breakers in house can't be inspected without access.
Pay re inspection fee prior to re scheduling.
|
|
02/20/2020 | **PERMIT FINAL | ADAM KINGSLEY | PASS | eTRAKiT Inspection Request | 2/18/2020 10:32:01 AM
2/18/2020 10:32 AM PHOENIX ENERGY FULFILLMENT INC DBA PHOENIX SOLAR ENERGY
Contact Name: PHOENIX ENERGY FULFILLMENT INC DBA PHOENIX SOLAR ENERGY
Site Address: 15756 FITZGERALD CT
Phone: 5309179956
e-Mail: OPERATIONS@phoenixsolarinc.com
|
|