08/15/2019 | FOUNDATION/FOOTINGS | ADAM KINGSLEY | CANCELLED | Cancelled on 8/15/2019 at 9:41 AM | |
|
08/20/2019 | FOUNDATION/FOOTINGS | WOODY TOWNSEND | PASS | 032483-02 - Scheduled by IVR. | 8/20/2019 2:08:54 PM
All footings except front porch piers.
Spoke with engineer on site and two pour foundation with #4 4'' o.c. Slab ties wet set are approved.
8/20/2019 5:00:46 PM
All footings except front porch piers.
Spoke with engineer on site and two pour foundation with #4 4'' o.c. Slab ties wet set are approved.
|
|
09/24/2019 | ROUGH PLUMBING | MIKE KNIGHT | CANCELLED | Cancelled on 9/24/2019 at 11:49 AM | |
|
09/26/2019 | UNDER SLAB PLUMBING | ADAM KINGSLEY | PASS | 034361-01 - Scheduled by IVR. | 9/26/2019 10:54:59 AM
Radiant floor & pre slab
|
|
| ROUGH FRAME | DSINSPECTION | | VOIDED (MJP2 12/2/2019) | 12/2/2019 8:47:10 AM
Inspection voided by MJP2. Most recent remarks follow: AM REQEUST- 530-321-2032 SUE
|
|
12/23/2019 | ROUGH FRAME | SCOTT YOUNG | CANCELLED | 037378-01 - Scheduled by IVR. | |
|
07/14/2020 | 4-WAY ROUGH FRAME | RICHARD PRATT | FAIL | | 7/14/2020 6:42:25 AM
rpratt changed Inspection Date/Time from 07/14/2020 08:00 AM to 07/14/2020 5:00 PM
7/14/2020 6:53:45 AM
rpratt changed Inspection Date/Time from 07/14/2020 05:00 PM to 07/14/2020 5:30 PM
7/14/2020 8:13:07 PM
Provide draft stop at the soffit to wall line - kitchen and water heater closet.
Shorten up the bath exhaust ducts, remove excess rather than coiling.
Straighten and properly support the hvac duct above the master bedroom entry.
Provide insulation around the line set at the splices - both
Make up electrical at the metal boxes secure the grounds
Install titan at kitchen door.
Recall inspection when completed.
|
|
07/20/2020 | 4-WAY ROUGH FRAME | ADAM KINGSLEY | PASS | 043934-01 - Scheduled by IVR. | 7/20/2020 9:56:14 AM
Previous corrections are completed.
Verified roof nail & Shearwall inspections previously passed, 12.23.19 by SVY. See attached photo.
|
|
09/01/2020 | SHOWER PAN/TUB TEST | RICHARD PRATT | PASS | 045236-01 - Scheduled by IVR. | 9/1/2020 7:00:27 AM
rpratt changed Inspection Date/Time from 09/01/2020 08:00 AM to 09/01/2020 10:30 AM
9/1/2020 5:46:30 PM
Shower pan , slope to drain and weeps clear - approved
|
|
12/17/2020 | GAS TEST | RICHARD PRATT | PASS | 048334-03 - Scheduled by IVR. | 12/17/2020 6:51:55 AM
rpratt changed Inspection Date/Time from 12/17/2020 08:00 AM to 12/17/2020 09:00 AM
12/17/2020 11:10:05 AM
LP Gas psi test - Approved
|
|
12/17/2020 | GAS PIPING | RICHARD PRATT | PASS | 048334-02 - Scheduled by IVR. | 12/17/2020 6:52:05 AM
rpratt changed Inspection Date/Time from 12/17/2020 08:00 AM to 12/17/2020 09:00 AM
12/17/2020 11:10:14 AM
House gas psi test - approved
|
|
12/17/2020 | PLUMBING TOPOUT | RICHARD PRATT | NOT REQUIRED | 048334-01 - Scheduled by IVR. | 12/17/2020 6:52:15 AM
rpratt changed Inspection Date/Time from 12/17/2020 08:00 AM to 12/17/2020 09:00 AM
12/17/2020 11:10:26 AM
Already performed at 4 way inspection.
|
|
12/18/2020 | CAL FIRE FINAL INSPE | CHRIS BOYD | PASS | | |
|
01/04/2021 | TAG LPG | RICHARD PRATT | PASS | | 1/4/2021 3:29:09 PM
LP Gas Tag - Approved
|
|
06/04/2021 | ENV HEALTH RELEASE | DARREN JONES | PASS | ok to rls | 6/4/2021 1:13:36 PM
septic finalled 6/4/2021
|
|
07/23/2021 | **PERMIT FINAL | SCOTT YOUNG | FAIL | | 7/23/2021 12:08:28 PM
1. All outlets on kitchen counter top need to be GFCI.
2. Label sub panel in house.
3. Have electrician check kitchen countertop receptacles, they seem to have a short,
4. Strap hot water heater.
5. HERS testing has not been done.
6. Anti siphon devices required on all exterior hose bibs.
7. Condenser units have a max amp rating of 25 amps, one is fused at 30 amps and the other is a disconnect,sub panel is not labeled.
Unable to verify.
8.
7/23/2021 12:38:25 PM
1. All outlets on kitchen counter top need to be GFCI.
2. Label sub panel in house.
3. Have electrician check kitchen countertop receptacles, they seem to have a short,
4. Strap hot water heater.
5. HERS testing has not been done.
6. Anti siphon devices required on all exterior hose bibs.
7. Condenser units have a max amp rating of 25 amps, one is fused at 30 amps and the other is a disconnect,sub panel is not labeled.
Unable to verify.
8.
7/23/2021 12:53:06 PM
1. All outlets on kitchen counter top need to be GFCI.
2. Label sub panel in house.
3. Have electrician check kitchen countertop receptacles, they seem to have a short,
4. Strap hot water heater.
5. HERS testing has not been done.
6. Anti siphon devices required on all exterior hose bibs.
7. Condenser units have a max amp rating of 25 amps, one is fused at 30 amps and the other is a disconnect,sub panel is not labeled.
Unable to verify.
8.
|
|
02/28/1850 | NPDES | QUENTIN CARTER | | VOIDED (WET 9/28/2021) | 9/28/2021 5:13:17 PM
Inspection voided by WET.
|
|
09/29/2021 | **PERMIT FINAL | WOODY TOWNSEND | CANCELLED | 054801-01 - Scheduled by IVR. | |
|
10/01/2021 | **PERMIT FINAL | SCOTT YOUNG | PASS | 054866-01 - Scheduled by IVR. | 10/2/2021 7:18:14 AM
Corrections have been completed.
10/4/2021 6:03:50 AM
Corrections have been completed.
|
|