02/28/1850 | NPDES | | | VOIDED (TOM BLIXT 1/14/2019) | |
|
| CAL FIRE FINAL INSPE | JOHN GADDIE | PASS | | |
|
06/27/2019 | PGE ELECTRIC TAG | ADAM KINGSLEY | PASS | 030306-01 - Scheduled by IVR. | 6/27/2019 2:23:27 PM
Construction power approved
|
|
07/22/2019 | UNDER SLAB PLUMBING | WOODY TOWNSEND | PASS | 031296-02 - Scheduled by IVR. | |
|
07/22/2019 | FOUNDATION/FOOTINGS | WOODY TOWNSEND | FAIL | 031296-01 - Scheduled by IVR. | 7/22/2019 4:40:19 PM
1. Needs spread footings plan.
2. Needs interior footing per plan.
3. Install interior form boards for two pour area.
4. Install ufer.
5. Have engineer clarify slab tie length.
|
|
07/24/2019 | FOUNDATION/FOOTINGS | WOODY TOWNSEND | PASS | 031393-01 - Scheduled by IVR. | |
|
08/05/2019 | PRE-SLAB | SCOTT YOUNG | PASS | 031850-01 - Scheduled by IVR. | |
|
09/19/2019 | SHEARWALL/B.W.P.-EXT | ADAM KINGSLEY | PASS | 034102-02 - Scheduled by IVR. | |
|
09/19/2019 | ROOF NAIL | ADAM KINGSLEY | PASS | 034102-01 - Scheduled by IVR. | |
|
10/28/2019 | 4-WAY ROUGH FRAME | PHILLIP MYERS | PASS | 035480-01 - Scheduled by IVR. | |
|
11/19/2019 | SPRINKLER SYSTEM | SCOTT YOUNG | VOID | 036092-01 - Scheduled by IVR. | |
|
11/25/2019 | DRYWALL NAIL/SCREW | SCOTT YOUNG | NOT REQUIRED | 036379-01 - Scheduled by IVR. | |
|
11/26/2019 | ENV HEALTH RELEASE | DARREN JONES | PASS | ok to rls | |
|
02/28/1850 | IMPACT FEES DUE | PERMIT CENTER | | VOIDED (MJP2 2/13/2020) | 2/13/2020 8:02:37 AM
Inspection voided by MJP2.
|
|
02/13/2020 | **PERMIT FINAL | ADAM KINGSLEY | FAIL | 038973-01 - Scheduled by IVR. | 2/13/2020 1:32:10 PM
1. Provide solid landing at entrance door.
2. GFCI protection required for 15A & 20A receptacles located at bathroom, kitchen counter and garage (AFCI only is installed). Replace AFCI receptacles with GFCI or equal.
3. Provide pipe insulation at water heater hot & cold water supply pipes.
4. Missing CF3R forms, update CalCerts registry to show project completed
|
|
02/20/2020 | **PERMIT FINAL | PHILLIP MYERS | PASS | 039231-01 - Scheduled by IVR. | 2/20/2020 12:33:29 PM
All Corrections complete.
|
|