Permit No. B18-2949 Permit Type   RESIDENTIAL Site Address   167 SOLANA DR
OROVILLE, CA 95966
Applied   12/06/2018 Applicant   AARON SCHMIDT
Approved   05/31/2019 Owner   SCHMIDT AARON & SUSAN
Issued   11/22/2019 Contractor   OB
Parent Permit No.   Description   REPL SFD (3729) GAR (1064) COVD (1394)
  Notes  
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

ENV HEALTH RELEASEKATTY HERNANDEZPASS

 11/25/2019UNDERGROUND PLUMBINGWOODY TOWNSENDPASS11/26/2019 7:32:41 AM Setbacks and underslab plumbing approved.

 12/05/2019FOUNDATION/FOOTINGSPHILLIP MYERSPASSPM REQUEST12/3/2019 2:53:29 PM 12/3/2019 2:53 PM Aaron Schmidt Contact Name: Aaron Schmidt Site Address: 167 SOLANA DR Phone: 5303704034 e-Mail: aps_282@yahoo.com

 01/02/2020PRE-SLABPHILLIP MYERSPASS

 01/17/2020PRE-SLABPHILLIP MYERSPASSGarage slab only if needed?1/15/2020 8:24:27 PM 1/15/2020 8:24 PM Aaron Schmidt Contact Name: Aaron Schmidt Site Address: 167 SOLANA DR Phone: 5303704034 e-Mail: aps_282@yahoo.com 1/17/2020 10:18:52 AM Pre-slab is for garage area

 02/14/2020FOUNDATION/FOOTINGSADAM KINGSLEYCANCELLED

 02/18/2020FOUNDATION/FOOTINGSPHILLIP MYERSPASS

 06/04/2020PRE-SLABSCOTT YOUNGPASSeTRAKiT Inspection Request6/2/2020 7:56:56 PM 6/2/2020 7:56 PM Aaron Schmidt Contact Name: Aaron Schmidt Site Address: 167 SOLANA DR Phone: 5303704034 e-Mail: aps_282@yahoo.com

 07/16/2020PRE-SLABADAM KINGSLEYPARTIALeTRAKiT Inspection Request7/15/2020 9:21:40 AM 7/15/2020 9:21 AM Aaron Schmidt slab on metal deck south end of house Contact Name: Aaron Schmidt Site Address: 167 SOLANA DR Phone: 5303704034 e-Mail: aps_282@yahoo.com 7/16/2020 9:58:52 AM Elevated Concrete deck & underfloor deck framing only, approved.

 10/09/2020ROOF NAILADAM KINGSLEYPASSeTRAKiT Inspection Request10/7/2020 7:28:34 PM 10/7/2020 7:28 PM Aaron Schmidt Contact Name: Aaron Schmidt Site Address: 167 SOLANA DR Phone: 5303704034 e-Mail: aps_282@yahoo.com

 10/09/2020SHEARWALL/B.W.P.-EXTADAM KINGSLEYFAIL10/9/2020 2:42:46 PM 1. Install post caps & straps/ mechanical connections or equal, per detail 13/SD & 14/SD as identified on roof plan. 2. Missing 64" CS16 at two locations. Install corner strap per detail 18/SD or equal as identified on floor plan. 3. Missing 48" CS16 at two locations. Install at plate height change/break or equal per floor plan. 4. Install A35 clips or equal at interior Shearwall/rafter connection per detail 17/SD. Note: HD's & AB's verified at Shearwall #2. OK to sheath both sides.

 10/21/2020STRAPS/HOLDDOWNSSCOTT YOUNGPASSeTRAKiT Inspection Request10/20/2020 1:11:37 PM 10/20/2020 1:11 PM Aaron Schmidt Shear Nailing Contact Name: Aaron Schmidt Site Address: 167 SOLANA DR Phone: 5303704034 e-Mail: aps_282@yahoo.com 10/22/2020 5:06:23 AM All corrections addressed, contractor also has revisions from engineer.

 11/09/2020FIRE SPRINKLERSSCOTT YOUNGFAIL11/9/2020 11:48:44 AM Not ready for 4 way rough. Fire sprinkler plans not onsite.

 03/05/20214-WAY ROUGH FRAMESCOTT YOUNGFAILALSO FIRE SPRINKLERS3/4/2021 9:22:46 AM SYSTEM WOULD NOT ALLOW INSPECTION TO BE SET FOR 3/5 3/8/2021 6:18:32 AM 1.Secure all DWV mid span . 2. A large portion of duct work has been run in the porch over hang. There is also no acces. 3. Change out Romex to thhn wire in slab ( island ) 4. Fill in under bathtub drain , mortar or like to rodent proof. 5. Tighten all holdown nuts prior to insulating. 6. Large bonus room has been built above garage, this will be condition, this is not on the approved plans. This has been wired and has fire sprinklers. Revised plans must be submitted to the county . This must be inspected with approved plans at this time prior to insulation . 7. Fire sprinkler plan does not reflect the bonus room, or sprinklers .

 04/13/20214-WAY ROUGH FRAMEADAM KINGSLEYFAILeTRAKiT Inspection Request4/12/2021 12:02:10 PM 4/12/2021 12:02 PM Aaron Schmidt Contact Name: Aaron Schmidt Site Address: 167 SOLANA DR Phone: 5303704034 e-Mail: aps_282@yahoo.com 4/13/2021 3:31:47 PM Previous corrections are completed except, 1. Fire sprinkler permit plan revision not approved at present. Note: space above garage retrofitted to attic space. Fire sprinkler heads to remain, per owner.

 04/22/20214-WAY ROUGH FRAMEADAM KINGSLEYPASS4/22/2021 7:30:37 AM FIRE SPRINKLER REVISION PROVIDED. NOTE: ATTIC/STORAGE AREA ABOVE GARAGE RETURNED TO ATTIC SPACE. SPRINKLER COVERAGE AREAS REMAINED. 5/12/2021 9:06:44 AM REVISED ENERGY CALCULATIONS ATTACHED. WHOLE HOUSE FAN OMITTED. PV SYSTEM ADDED.

 10/06/2021SHOWER PAN/TUB TESTWOODY TOWNSENDPASS054970-01 - Scheduled by IVR.

 10/06/2021CAL FIRE FINAL INSPEJOHN GADDIEPASS10/6/2021 3:00:16 PM OK to Final

 11/02/2021**PERMIT FINALWOODY TOWNSENDCANCELLEDeTRAKiT Inspection Request10/29/2021 1:44:02 PM 10/29/2021 1:44 PM Aaron Schmidt Contact Name: Aaron Schmidt Site Address: 167 SOLANA DR Phone: 5303704034 e-Mail: aps_282@yahoo.com

 11/18/2021**PERMIT FINALADAM KINGSLEYPASSeTRAKiT Inspection Request11/16/2021 9:23:02 PM 11/16/2021 9:23 PM Aaron Schmidt Contact Name: Aaron Schmidt Site Address: 167 SOLANA DR Phone: 5303704034 e-Mail: aps_282@yahoo.com