06/04/2020 | ROUGH PLUMBING | SCOTT YOUNG | FAIL | eTRAKiT Inspection Request | 6/3/2020 8:12:36 AM
6/3/2020 8:12 AM Derek Moffitt
Contact Name: Derek Moffitt
Site Address: 3087 COW TRAIL LN
Phone: 5303701906
e-Mail: moffitt.derek@gmail.com
6/5/2020 7:23:03 AM
1. All plumbing DWV pipes must be exposed and accessible for inspection.
2. No water in dwv pipes at time of inspection,leading me to believe there is a or multiple leaks. Unable to verify due to pipes being covered.
3.All footings need to be clean and debris free. They will need to be dug out and squared off at base of footing, they are beginning to fill back in with dirt and becoming compacted.
4. There is a considerable amount of fill left inside of the footings, leading to concerns as to how your removal of this will be approached due to all plumbing trenches and footings and form boards in place.
|
|
06/09/2020 | UNDER SLAB PLUMBING | ADAM KINGSLEY | PASS | Plumbing Only. Mono Pour | 6/5/2020 4:43:13 PM
6/5/2020 4:43 PM Derek Moffitt
Contact Name: Derek Moffitt
Site Address: 3087 COW TRAIL LN
Phone: 5303701906
e-Mail: moffitt.derek@gmail.com
|
|
06/09/2020 | SETBACKS | ADAM KINGSLEY | PASS | | |
|
06/16/2020 | FOUNDATION/FOOTINGS | ADAM KINGSLEY | PASS | eTRAKiT Inspection Request | 6/15/2020 6:48:42 AM
6/15/2020 6:48 AM Derek Moffitt
Contact Name: Derek Moffitt
Site Address: 3087 COW TRAIL LN
Phone: 5303701906
e-Mail: moffitt.derek@gmail.com
6/16/2020 9:21:10 PM
Monolithic preslab & eufer ground included.
Notified owner under construction flood elevation certificate required at next inspection.
|
|
07/02/2020 | CMU 1ST POUR | SCOTT YOUNG | FAIL | | 7/2/2020 12:28:29 PM
First pour on cmu block wall not to exceed 5'4" .
Wall is 8' high, unable to see down into wall more than 3'.
Approved plans were not left onsite, one sheet was left, it was not an approved,stamped page,nor was it the N-2 page that the plans for the cmu wall were located.
Call for reinspection.
|
|
07/07/2020 | CMU 1ST POUR | RICHARD PRATT | FAIL | eTRAKiT Inspection Request | 7/6/2020 1:12:06 PM
7/6/2020 1:12 PM Derek Moffitt
Contact Name: Derek Moffitt
Site Address: 3087 COW TRAIL LN
Phone: 5303701906
e-Mail: moffitt.derek@gmail.com
7/7/2020 6:31:10 AM
rpratt changed Inspection Date/Time from 07/07/2020 08:00 AM to 07/07/2020 12:30 PM
7/7/2020 6:59:52 PM
No one on site, permit and approved plans were not available.
Recall inspection when someone can be on-site with the approved plans.
7/8/2020 6:03:50 AM
No one on site, permit and approved plans were not available.
Recall inspection when someone can be on-site with the approved plans.
|
|
07/14/2020 | CMU 1ST POUR | SCOTT YOUNG | PASS | eTRAKiT Inspection Request | 7/12/2020 5:42:58 PM
7/12/2020 5:42 PM Derek Moffitt
Site plans in nearby storage container through sliding glass door
Contact Name: Derek Moffitt
Site Address: 3087 COW TRAIL LN
Phone: 5303701906
e-Mail: moffitt.derek@gmail.com
7/14/2020 12:49:35 PM
They have opened up weep holes at bottom of cmu for first stage. 8' wall.
7/14/2020 2:44:51 PM
They have opened up weep holes at bottom of cmu for first stage. 8' wall.
7/14/2020 2:58:52 PM
They have opened up weep holes at bottom of cmu for first stage. 8' wall.
|
|
09/08/2020 | ROOF FRAME/SHEATHING | SCOTT YOUNG | FAIL | eTRAKiT Inspection Request | 9/4/2020 4:27:16 PM
9/4/2020 4:27 PM Derek Moffitt
Frame, Roof and shear.
Contact Name: Derek Moffitt
Site Address: 3087 COW TRAIL LN
Phone: 5303701906
e-Mail: moffitt.derek@gmail.com
9/8/2020 7:36:07 AM
syoung changed Inspection Date/Time from 09/08/2020 to 09/08/2020
9/8/2020 9:19:45 PM
Approved set of plans were not onsite.
All holdowns did not have nuts .
9/8/2020 9:50:13 PM
Approved set of plans were not onsite.
All holdowns did not have nuts .
9/9/2020 7:33:04 AM
Approved set of plans were not onsite.
All holdowns did not have nuts .
9/9/2020 7:43:20 AM
Approved set of plans were not onsite.
All holdowns did not have nuts .
9/9/2020 7:46:14 AM
Approved set of plans were not onsite.
All holdowns did not have nuts .
9/9/2020 7:49:46 AM
Approved set of plans were not onsite.
All holdowns did not have nuts .
|
|
09/16/2020 | ROOF FRAME/SHEATHING | SCOTT YOUNG | PASS | eTRAKiT Inspection Request | 9/15/2020 8:48:14 AM
9/15/2020 8:48 AM Derek Moffitt
Contact Name: Derek Moffitt
Site Address: 3087 COW TRAIL LN
Phone: 5303701906
e-Mail: moffitt.derek@gmail.com
|
|
12/01/2020 | 4-WAY ROUGH FRAME | SCOTT YOUNG | FAIL | eTRAKiT Inspection Request | 11/30/2020 11:07:47 AM
11/30/2020 11:07 AM Derek Moffitt
Contact Name: Derek Moffitt
Site Address: 3087 COW TRAIL LN
Phone: 5303701906
e-Mail: moffitt.derek@gmail.com
12/1/2020 12:22:45 PM
1. Frame attic acces for west side of house.
2.cover all vents and c.a.r. With cardboard or like to close of from dust during construction.
3. Condensation lines have not been run.
4. Letter from engineer for Titans used. In excess of 25.
5. Replace stud at wall in bdrm 3 at HTT4
6. Letter from engineer on pantry/ kitchen plan change. None of the walls seem to be structural.
12/1/2020 1:11:17 PM
1. Frame attic acces for west side of house.
2.cover all vents and c.a.r. With cardboard or like to close of from dust during construction.
3. Condensation lines have not been run.
4. Letter from engineer for Titans used. In excess of 25.
5. Replace stud at wall in bdrm 3 at HTT4
6. Letter from engineer on pantry/ kitchen plan change. None of the walls seem to be structural.
12/2/2020 6:32:29 AM
1. Frame attic acces for west side of house.
2.cover all vents and c.a.r. With cardboard or like to close of from dust during construction.
3. Condensation lines have not been run.
4. Letter from engineer for Titans used. In excess of 25.
5. Replace stud at wall in bdrm 3 at HTT4
6. Letter from engineer on pantry/ kitchen plan change. None of the walls seem to be structural.
|
|
12/14/2020 | 4-WAY ROUGH FRAME | ADAM KINGSLEY | FAIL | eTRAKiT Inspection Request | 12/10/2020 8:43:51 PM
12/10/2020 8:43 PM Derek Moffitt
Contact Name: Derek Moffitt
Site Address: 3087 COW TRAIL LN
Phone: 5303701906
e-Mail: moffitt.derek@gmail.com
12/14/2020 9:22:48 AM
Previous corrections not addressed. See below
SVY 12/1/2020 12:22:45 PM
1. Frame attic acces for west side of house.
2.cover all vents and c.a.r. With cardboard or like to close of from dust during construction.
3. Condensation lines have not been run.
4. Letter from engineer for Titans used. In excess of 25.
5. Replace stud at wall in bdrm 3 at HTT4
6. Letter from engineer on pantry/ kitchen plan change. None of the walls seem to be structural.
Recall inspection after corrections completed
12/16/2020 7:38:19 PM
ITEMS #4 & 5 ADDRESSED. LETTER ATTACHED.
|
|
12/15/2020 | 4-WAY ROUGH FRAME | ADAM KINGSLEY | CANCELLED | | 12/15/2020 10:20:29 AM
By owner via phone.
|
|
12/17/2020 | 4-WAY ROUGH FRAME | ADAM KINGSLEY | PASS | | 12/15/2020 3:49:46 PM
AM PLEASE
12/17/2020 8:49:35 AM
Previous corrections are completed
|
|
12/17/2020 | STUCCO (LATH) | ADAM KINGSLEY | PASS | | |
|
01/06/2021 | STUCCO (SCRATCH) | SCOTT YOUNG | NOT REQUIRED | AM PLEASE | |
|
01/14/2021 | UNDERGROUND ELECTRIC | ADAM KINGSLEY | PASS | | 1/12/2021 3:43:28 PM
AM PLEASE
1/14/2021 9:56:05 AM
SFD to meter/electric service location.
|
|
01/25/2021 | PGE ELECTRIC TAG | ADAM KINGSLEY | PASS | | 1/21/2021 3:06:08 PM
AM PLEASE
1/25/2021 9:35:22 AM
Construction power approved
|
|
03/16/2021 | SHOWER PAN/TUB TEST | RICHARD PRATT | FAIL | | 3/16/2021 7:01:33 AM
rpratt changed Inspection Date/Time from 03/16/2021 08:00 AM to 03/16/2021 4:00 PM
3/16/2021 5:04:01 PM
No sub drain with weep holes installed in either shower.
No water in the master shower.
Recall inspection when completed.
|
|
03/19/2021 | SHOWER PAN/TUB TEST | WOODY TOWNSEND | PASS | | 3/19/2021 3:25:25 PM
X2
|
|
| CAL FIRE FINAL INSPE | CHRIS BOYD | PARTIAL | | 3/24/2021 10:26:09 AM
Need to post address and provide blank cover in electrical panel.
|
|
04/13/2021 | GAS TEST | ADAM KINGSLEY | PASS | | 4/13/2021 11:00:24 AM
House test & underground pipe test. LPG tag issued (in residential electric meter).
|
|
04/13/2021 | UNDERGROUND GAS | ADAM KINGSLEY | PASS | | 4/13/2021 11:00:28 AM
akingsley changed Inspection Type from GAS PIPING to UNDERGROUND GAS
4/13/2021 11:04:43 AM
Tank location to SFD
|
|
08/11/2021 | PW FINAL | ROAD DISTRICT 4 | PASS | SEE NOTES | 8/11/2021 3:31:43 PM
SEE ENCROACHMENT PERMIT PW19-0194.
|
|
08/12/2021 | **PERMIT FINAL | RICHARD PRATT | CANCELLED | NEED TO PAY CWIF FIRST | 8/12/2021 7:16:16 AM
rpratt changed Inspection Date/Time from 08/12/2021 08:00 AM to 08/12/2021 2:00 PM
8/12/2021 4:51:21 PM
Customer called to cancel - unable to pay final fees, county doesn't take AmEx
|
|
| IMPACT FEES DUE | PERMIT CENTER | PASS | | |
|
08/12/2021 | **PERMIT FINAL | RICHARD PRATT | CANCELLED | | |
|
08/16/2021 | **PERMIT FINAL | RICHARD PRATT | FAIL | | 8/16/2021 7:03:36 AM
Rpratt changed Inspection Date/Time from 08/16/2021 08:00 AM to 08/16/2021 1:30 PM
8/16/2021 4:31:11 PM
Complete CalFire corrections.
Provide a clear workspace in front of the A/ C disconnects
Provide tamper resistant caps for the condensers.
Provide a permanent screw type cap for waste line at the west side of the building.+.
|
|
09/27/2021 | **PERMIT FINAL | RICHARD PRATT | PARTIAL | | 9/27/2021 7:01:48 AM
rpratt changed Inspection Date/Time from 09/27/2021 08:00 AM to 09/27/2021 08:30 AM
10/4/2021 7:03:16 AM
Obtain Environmental Heath Final Approval - ok to Final project once completed
|
|
11/09/2022 | ENV HEALTH RELEASE | KATTY HERNANDEZ | PASS | SEE NOTES | 9/28/2021 1:31:38 PM
EHWS18-0115 (WELL) AND EHS18-0380 (SEPTIC) RECEIVED FINAL APPROVAL. PENDING WATER LAB REPORT FOR COLIFORM BACTERIA AND NITRATE LEVEL.
10/24/2022 2:13:49 PM
PENDING TWO CONSECUTIVE COLIFORM BACTERIA SAMPLE REPORTS WITH NEGATIVE RESULTS.
11/7/2022 9:45:30 AM
NITRATE REPORT OKAY. PENDING TWO CONSECUTIVE COLIFORM BACTERIA SAMPLE REPORTS WITH NEGATIVE RESULTS. PROVIDED WATER SAMPLING INFORMATION LINK.
|
|
11/09/2022 | **PERMIT FINAL | DSINSPECTION | PASS | ALL CONDITIONS HAVE BEEN MET | 3/16/2023 2:00:32 PM
EH APPROVAL GIVEN 11/9/22
|
|