09/18/2018 | FOUNDATION/FOOTINGS | ADAM KINGSLEY | CANCELLED | | 9/17/2018 3:23:15 PM
PM REQUESTED RAMAN 530.301.5779
9/18/2018 12:21:11 PM
Not ready, work not complete
|
|
09/18/2018 | UNDERGROUND PLUMBING | ADAM KINGSLEY | PASS | | 9/18/2018 12:21:09 PM
Under slab plumbing for addition only, approved
|
|
05/13/2019 | PGE ELECTRIC TAG | MIKE KNIGHT | PASS | | |
|
10/24/2018 | 4-WAY ROUGH FRAME | SCOTT YOUNG | CANCELLED | | |
|
| 4-WAY ROUGH FRAME | SCOTT YOUNG | | VOIDED (SONIA NELSON 10/23/2018) | |
|
11/07/2018 | 4-WAY ROUGH FRAME | MIKE GENNA | PASS | | 11/7/2018 11:46:28 AM
Provide catwalk for access to fau
Retie top plates at wall furnace
|
|
09/25/2018 | PRE-SLAB | SCOTT YOUNG | PASS | PM REQUESTED | 9/24/2018 9:12:24 AM
RAMAN 301-5779
9/25/2018 12:34:23 PM
No one onsite, approved plans were left attached to interior wall.
|
|
| ENV HEALTH RELEASE | YVETTE CASTANON | PASS | | |
|
| NPDES | | | | |
|
09/19/2019 | GAS TEST | ADAM KINGSLEY | PASS | | |
|
09/19/2019 | **PERMIT FINAL | ADAM KINGSLEY | FAIL | | 9/19/2019 3:16:52 PM
1. CalFire final approval required.
2. Water heater PTRV termination pointed parallel to grade. Point termination towards the ground.
3. Building Drain clean outs missing clean out plugs. Test caps not listed for permanent use. Install permanent plugs.
4. Receptacle right of kitchen sink not GFCI protected. Provide GFCI protection for receptacles within 6' of sink.
5. Min 100cfm ventilation not provided for kitchen. Install over range microwave & duct or equal. Also required cooking facility.
6. Energy compliance documents not completed. Update CalCerts registry to show project completed.
7. Provide approved plans for reinspection.
|
|
09/19/2019 | PGE GAS TAG | ADAM KINGSLEY | PASS | | |
|
10/31/2019 | CAL FIRE FINAL INSPE | CHRIS BOYD | PASS | | |
|
11/06/2019 | **PERMIT FINAL | SCOTT YOUNG | PASS | eTRAKiT Inspection Request | 11/4/2019 12:13:42 PM
11/4/2019 12:13 PM Ramandeep Singh
Contact Name: Ramandeep Singh
Site Address: 43 OBERMEYER AVE
Phone: 5303015779
e-Mail: legendproperties1@gmail.com
|
|