Permit No. B12-0723 Permit Type   MISCELLANEOUS Site Address   491 OBERMEYER AVE
GRIDLEY, CA 95948
Applied   05/21/2012 Applicant   ROMO, JOSE
Approved   06/26/2012 Owner   ROMO, JOSE
Issued   06/26/2012 Contractor   OWNER
Parent Permit No.   Description   DETACHED GARAGE (1152 SF)
  Notes  
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

 07/24/2012ROUGH ELECTRICALRICHARD NIXONFAIL7/24/2012 12:00:00 AM (7/24/2012 3:34 PM RJN) 1 Post address on house. 2 Provide 3x3 washers on all bolts. 3 Provide 2 bolts in each shear wall. 4 Verify slab and under slab plumbing, and obtain permit for plumbing. 5 Install 8' wall as per plane. 6 Remove plywood in truss for storage. 7 Install electrical panel with approved ground.

 07/17/20124-WAY ROUGH FRAMEROBERT PORTAPASS

 08/03/2012ROUGH ELECTRICALWOODY TOWNSENDPASS

 08/13/2012ENV HEALTH RELEASECHARLOTTE WALTERSPASSPass 6-14-12 clw8/13/2012 12:00:00 AM (6/14/2012 4:30 PM CLW) Pass, 6-14-12 clw

 05/21/2012NPDESVOIDVOIDED (TLB2 5/23/2012)

 08/13/2012PERMIT FINALCURTIS L. JOHNSONFAIL053276-01 - Scheduled by IVR.8/13/2012 12:00:00 AM (8/13/2012 1:53 PM CJ) 1. Obtain Cal-Fire and Public Works final approvals. 2. Provide GFI protection for all receptacle outlets inside and out. 3. Provide the correct weather proof cover for exterior receptacle which protects while the device is in use. 4. Provide level landing at exterior man-door within 7-3/4" of the door threshold. 5. Label all electrical circuits in panel. 6. Provide stc clips or other means of securing the interior braced walls to the trusses above. 7. Provide caps at future plumbing fixtures. Note: a permit is required prior to adding plumbing fixtures to the garage.

 08/03/2012ROUGH FRAMEWOODY TOWNSENDPASS053087-01 - Scheduled by IVR.

 07/03/2012FOUNDATION/FOOTINGSROBERT PORTAFAIL052381-01 - Scheduled by IVR.7/3/2012 12:00:00 AM (7/3/2012 4:20 PM RP) 1. Provide alternate brace walls at 2' 8" per plan

 07/05/2012FOUNDATION/FOOTINGSCURTIS L. JOHNSONPASS

 07/20/2012ROUGH ELECTRICALWOODY TOWNSENDFAIL7/20/2012 12:00:00 AM (7/20/2012 9:48 AM WET) Provide acceess to inspect elec. and framing.

 07/20/2012STUCCO (LATH)WOODY TOWNSENDPASSCall prior to in spect Jose 916-717-4838

 06/27/2012FOUNDATION/FOOTINGSWOODY TOWNSENDFAIL6/27/2012 12:00:00 AM (6/27/2012 10:01 AM WET) 1. Provide 2'8" brace wall at front and rear wall and install HD anchors. 2. Provide footing and rebar for interior brace walls. 3. Install ufer or ground rod is required for electrical. 4. Clean trash from footings and remove 2x blocks prior to pour.

 04/07/2021CAL FIRE FINAL INSPECHRIS BOYDPASS

 04/13/2021**PERMIT FINALADAM KINGSLEYFAILpm request4/13/2021 10:28:21 AM Previous final corrections completed except 1. Provide Butte County Public Works Final clearance. All that is needed for final.

 04/30/2021PUBLIC WKS CLEARANCEPASSSEE NOTES5/25/2012 12:00:00 AM (5/25/2012 9:21 AM JPV) Existing driveway conforms to County standard S-31 (no encroachment permit required). (6/1/2012 10:56 AM JPV) Pw08-0116 was never issued. (6/1/2012 10:56 AM JPV) Needs encroachment permit. Sent letter. 4/30/2021 1:22:50 PM SEE ATTACHED PHOTOS 5/1/2021 7:54:03 AM SEE ENCROACHMENT PERMIT PW12-0061.