07/24/2012 | ROUGH ELECTRICAL | RICHARD NIXON | FAIL | | 7/24/2012 12:00:00 AM
(7/24/2012 3:34 PM RJN)
1 Post address on house.
2 Provide 3x3 washers on all bolts.
3 Provide 2 bolts in each shear wall.
4 Verify slab and under slab plumbing, and obtain permit for plumbing.
5 Install 8' wall as per plane.
6 Remove plywood in truss for storage.
7 Install electrical panel with approved ground.
|
|
07/17/2012 | 4-WAY ROUGH FRAME | ROBERT PORTA | PASS | | |
|
08/03/2012 | ROUGH ELECTRICAL | WOODY TOWNSEND | PASS | | |
|
08/13/2012 | ENV HEALTH RELEASE | CHARLOTTE WALTERS | PASS | Pass 6-14-12 clw | 8/13/2012 12:00:00 AM
(6/14/2012 4:30 PM CLW)
Pass, 6-14-12 clw
|
|
05/21/2012 | NPDES | | VOID | VOIDED (TLB2 5/23/2012) | |
|
08/13/2012 | PERMIT FINAL | CURTIS L. JOHNSON | FAIL | 053276-01 - Scheduled by IVR. | 8/13/2012 12:00:00 AM
(8/13/2012 1:53 PM CJ)
1. Obtain Cal-Fire and Public Works final approvals.
2. Provide GFI protection for all receptacle outlets inside and out.
3. Provide the correct weather proof cover for exterior receptacle which protects while the device is in use.
4. Provide level landing at exterior man-door within 7-3/4" of the door threshold.
5. Label all electrical circuits in panel.
6. Provide stc clips or other means of securing the interior braced walls to the trusses above.
7. Provide caps at future plumbing fixtures. Note: a permit is required prior to adding plumbing fixtures to the garage.
|
|
08/03/2012 | ROUGH FRAME | WOODY TOWNSEND | PASS | 053087-01 - Scheduled by IVR. | |
|
07/03/2012 | FOUNDATION/FOOTINGS | ROBERT PORTA | FAIL | 052381-01 - Scheduled by IVR. | 7/3/2012 12:00:00 AM
(7/3/2012 4:20 PM RP)
1. Provide alternate brace walls at 2' 8" per plan
|
|
07/05/2012 | FOUNDATION/FOOTINGS | CURTIS L. JOHNSON | PASS | | |
|
07/20/2012 | ROUGH ELECTRICAL | WOODY TOWNSEND | FAIL | | 7/20/2012 12:00:00 AM
(7/20/2012 9:48 AM WET)
Provide acceess to inspect elec. and framing.
|
|
07/20/2012 | STUCCO (LATH) | WOODY TOWNSEND | PASS | Call prior to in spect Jose 916-717-4838 | |
|
06/27/2012 | FOUNDATION/FOOTINGS | WOODY TOWNSEND | FAIL | | 6/27/2012 12:00:00 AM
(6/27/2012 10:01 AM WET)
1. Provide 2'8" brace wall at front and rear wall and install HD anchors.
2. Provide footing and rebar for interior brace walls.
3. Install ufer or ground rod is required for electrical.
4. Clean trash from footings and remove 2x blocks prior to pour.
|
|
04/07/2021 | CAL FIRE FINAL INSPE | CHRIS BOYD | PASS | | |
|
04/13/2021 | **PERMIT FINAL | ADAM KINGSLEY | FAIL | pm request | 4/13/2021 10:28:21 AM
Previous final corrections completed except
1. Provide Butte County Public Works Final clearance.
All that is needed for final.
|
|
04/30/2021 | PUBLIC WKS CLEARANCE | | PASS | SEE NOTES | 5/25/2012 12:00:00 AM
(5/25/2012 9:21 AM JPV)
Existing driveway conforms to County standard S-31 (no encroachment permit required).
(6/1/2012 10:56 AM JPV)
Pw08-0116 was never issued.
(6/1/2012 10:56 AM JPV)
Needs encroachment permit. Sent letter.
4/30/2021 1:22:50 PM
SEE ATTACHED PHOTOS
5/1/2021 7:54:03 AM
SEE ENCROACHMENT PERMIT PW12-0061.
|
|