Permit No. EHS23-0106 Permit Type   EH SEPTIC Site Address   681 MIDDLE HONCUT RD
OROVILLE, CA 95965
Applied   04/26/2023 Applicant   EQUA ENGINEERING
Approved   09/14/2023 Owner   WOODSTOCK HOLDINGS LLC
Issued   09/14/2023 Contractor  
Parent Permit No.   Description   3-BDRM REPAIR
  Notes  
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

SEPTIC FINALKATTY HERNANDEZPENDING AIPN

 07/26/2024SEPTIC FINALKATTY HERNANDEZPARTIALSEE NOTES8/5/2024 9:02:23 AM 1500 GALLON MERRILL & SONS CONCRETE TANK FOLLOWED BY 1500 GALLON MERRILL & SONS CONCRETE DOSING TANK. RISERS TO GRADE AND SANITARY TEES IN PLACE. EFFLUENT FILTER IN PLACE. 80FT FROM TANK TO DISTRIBUTION VALVE. RISER OVER DISTRIBUTION VALVE. THREE ZONES AS SHOWN ON APPROVED PLAN. WILL PROVIDE THE FOLLOWING: CONFIRM TRACER WIRE WAS PLACED ON THE EFFLUENT LINE AND CLEAN ORIFICES WHICH PREVENTED EFFLUENT FROM REACHING 5FT SQUIRT HEIGHT. PROVIDE PHOTOS OF ORIFICE CAPS IN PLACE, FILTER FABRIC INPLACE, OBSERVATION PORTS IN PLACE, AND THE FINAL BACKFILL. PROVIDE PHOTO OF CONTROL BOX PROTECTED FROM THE SUN/RAIN. PROVIDE VIDEO/ DESIGNER SIGN OFF OF PUMP FLOATS OPERATING PROPERLY. PROVIDES PHOTOS OF TANK DESTRUCTION PROCESS. VERIFY LEACH LINES ARE 3FT WIDE. PROVIDE COMPLETED AS-BUILT REPORT. PROVIDE DESIGNER'S FINAL SIGN OFF LETTER. PROVIDE COPY OF RECORDED AIPN.