Permit No. B24-2981 Permit Type   MISCELLANEOUS Site Address   4520 NORD HWY
CHICO, CA 95973
Applied   12/02/2024 Applicant   KIM DECARLO
Approved   01/13/2025 Owner   DECARLO KATRINA M & NICHOLAS C
Issued   01/16/2025 Contractor   OWNER BUILDER
Parent Permit No.   Description   REMODEL (230) ADD (149)
  Notes  
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

 01/28/2025UNDER SLAB PLUMBINGRICHARD PRATTPASSeTRAKiT Inspection Request1/27/2025 9:43:12 AM 1/27/2025 9:43 AM Katrina DeCarlo Contact Name: Katrina DeCarlo Site Address: 4520 NORD HWY Phone: 9259635533 e-Mail: katrinadecarlo@gmail.com 1/28/2025 4:17:16 AM rpratt changed Inspection Date/Time from 01/28/2025 08:00 AM to 01/28/2025 12:30 PM 1/28/2025 12:09:42 PM rpratt changed Inspection Type from PRE-SLAB to UNDER SLAB PLUMBING 1/29/2025 5:50:10 AM Underslab plumbing - on test and Approved

 02/05/2025PRE-SLABSCOTT YOUNGPASSeTRAKiT Inspection Request2/3/2025 8:49:44 AM 2/3/2025 8:49 AM Katrina DeCarlo Contact Name: Katrina DeCarlo Site Address: 4520 NORD HWY Phone: 9259635533 e-Mail: katrinadecarlo@gmail.com 2/5/2025 7:01:53 AM Interior pre slab -Approved

 02/24/2025PRE-SLABRICHARD PRATTPASS2/24/2025 4:36:20 AM rpratt changed Inspection Date/Time from 02/24/2025 08:00 AM to 02/24/2025 09:00 AM 2/24/2025 5:05:33 PM Exterior pre pour slab - Approved

 02/24/20254-WAY ROUGH FRAMERICHARD PRATTFAIL2/24/2025 5:05:54 PM 1. Provide a king stud to each side of the window that is greater than 4 ft wide. - Typical framing A5 2. Provide support for the shower drain in the subfloor for upstairs. 3. Provide full structural support for the top plate break in the new exterior wall. 4. Ground all metal electrical boxes to the green grounding screw. 5. Recall the inspection when completed.

 02/27/20254-WAY ROUGH FRAMESCOTT YOUNGPASSeTRAKiT Inspection Request2/25/2025 4:50:38 PM 2/25/2025 4:50 PM Katrina DeCarlo Contact Name: Katrina DeCarlo Site Address: 4520 NORD HWY Phone: 9259635533 e-Mail: katrinadecarlo@gmail.com 2/28/2025 6:24:31 AM Approved All corrections have been completed. Ok to Sheetrock.

 05/05/2025ROOF NAILWOODY TOWNSENDFAILeTRAKiT Inspection Request5/1/2025 4:03:43 PM 5/1/2025 4:03 PM Katrina DeCarlo Contact Name: Katrina DeCarlo Site Address: 4520 NORD HWY Phone: 9259635533 e-Mail: katrinadecarlo@gmail.com 5/5/2025 4:53:28 PM Roof nail for addition. 1. Provide approved revised plans to omit balcony and change pitch of roof framing above laundry/bath addition. Roof nail is 6/12 at this time. Schedule 4-way inspection for addition when ready.

 06/13/20254-WAY ROUGH FRAMECHRISTOPHER ROBERTSFAILeTRAKiT Inspection Request6/11/2025 1:47:18 PM 6/11/2025 1:47 PM Katrina DeCarlo Contact Name: Katrina DeCarlo Site Address: 4520 NORD HWY Phone: 9259635533 e-Mail: katrinadecarlo@gmail.com 6/13/2025 3:22:04 PM No access, no homeowner or contractor on-site. Gate shut, beware of dog sign.

 06/17/20254-WAY ROUGH FRAMECHRISTOPHER ROBERTSFAILeTRAKiT Inspection Request6/13/2025 4:14:00 PM 6/13/2025 4:14 PM Katrina DeCarlo Contact Name: Katrina DeCarlo Site Address: 4520 NORD HWY Phone: 9259635533 e-Mail: katrinadecarlo@gmail.com 6/17/2025 12:21:44 PM 1. Submit revised plans for omitting of the balcony. Have approved set of plans on site. 2. Provide a port for gas line valve next to door. 3. Provide a strap for break in bottom plate outside wall and east wall. 4. Fill in mud sills throughout perimeter for (N) plumbing. 5. Provide shims for gaps in headers. Complete work and recall inspections. ** 4-way rough frame for kitchen approved by SY. Corrections for this 4-way are for laundry room and bathroom addition.