01/28/2025 | UNDER SLAB PLUMBING | RICHARD PRATT | PASS | eTRAKiT Inspection Request | 1/27/2025 9:43:12 AM
1/27/2025 9:43 AM Katrina DeCarlo
Contact Name: Katrina DeCarlo
Site Address: 4520 NORD HWY
Phone: 9259635533
e-Mail: katrinadecarlo@gmail.com
1/28/2025 4:17:16 AM
rpratt changed Inspection Date/Time from 01/28/2025 08:00 AM to 01/28/2025 12:30 PM
1/28/2025 12:09:42 PM
rpratt changed Inspection Type from PRE-SLAB to UNDER SLAB PLUMBING
1/29/2025 5:50:10 AM
Underslab plumbing - on test and Approved
|
|
02/05/2025 | PRE-SLAB | SCOTT YOUNG | PASS | eTRAKiT Inspection Request | 2/3/2025 8:49:44 AM
2/3/2025 8:49 AM Katrina DeCarlo
Contact Name: Katrina DeCarlo
Site Address: 4520 NORD HWY
Phone: 9259635533
e-Mail: katrinadecarlo@gmail.com
2/5/2025 7:01:53 AM
Interior pre slab -Approved
|
|
02/24/2025 | PRE-SLAB | RICHARD PRATT | PASS | | 2/24/2025 4:36:20 AM
rpratt changed Inspection Date/Time from 02/24/2025 08:00 AM to 02/24/2025 09:00 AM
2/24/2025 5:05:33 PM
Exterior pre pour slab - Approved
|
|
02/24/2025 | 4-WAY ROUGH FRAME | RICHARD PRATT | FAIL | | 2/24/2025 5:05:54 PM
1. Provide a king stud to each side of the window that is greater than 4 ft wide. - Typical framing A5
2. Provide support for the shower drain in the subfloor for upstairs.
3. Provide full structural support for the top plate break in the new exterior wall.
4. Ground all metal electrical boxes to the green grounding screw.
5. Recall the inspection when completed.
|
|
02/27/2025 | 4-WAY ROUGH FRAME | SCOTT YOUNG | PASS | eTRAKiT Inspection Request | 2/25/2025 4:50:38 PM
2/25/2025 4:50 PM Katrina DeCarlo
Contact Name: Katrina DeCarlo
Site Address: 4520 NORD HWY
Phone: 9259635533
e-Mail: katrinadecarlo@gmail.com
2/28/2025 6:24:31 AM
Approved
All corrections have been completed.
Ok to Sheetrock.
|
|
05/05/2025 | ROOF NAIL | WOODY TOWNSEND | FAIL | eTRAKiT Inspection Request | 5/1/2025 4:03:43 PM
5/1/2025 4:03 PM Katrina DeCarlo
Contact Name: Katrina DeCarlo
Site Address: 4520 NORD HWY
Phone: 9259635533
e-Mail: katrinadecarlo@gmail.com
5/5/2025 4:53:28 PM
Roof nail for addition.
1. Provide approved revised plans to omit balcony and change pitch of roof framing above laundry/bath addition.
Roof nail is 6/12 at this time.
Schedule 4-way inspection for addition when ready.
|
|
06/13/2025 | 4-WAY ROUGH FRAME | CHRISTOPHER ROBERTS | FAIL | eTRAKiT Inspection Request | 6/11/2025 1:47:18 PM
6/11/2025 1:47 PM Katrina DeCarlo
Contact Name: Katrina DeCarlo
Site Address: 4520 NORD HWY
Phone: 9259635533
e-Mail: katrinadecarlo@gmail.com
6/13/2025 3:22:04 PM
No access, no homeowner or contractor on-site. Gate shut, beware of dog sign.
|
|
06/17/2025 | 4-WAY ROUGH FRAME | CHRISTOPHER ROBERTS | FAIL | eTRAKiT Inspection Request | 6/13/2025 4:14:00 PM
6/13/2025 4:14 PM Katrina DeCarlo
Contact Name: Katrina DeCarlo
Site Address: 4520 NORD HWY
Phone: 9259635533
e-Mail: katrinadecarlo@gmail.com
6/17/2025 12:21:44 PM
1. Submit revised plans for omitting of the balcony. Have approved set of plans on site.
2. Provide a port for gas line valve next to door.
3. Provide a strap for break in bottom plate outside wall and east wall.
4. Fill in mud sills throughout perimeter for (N) plumbing.
5. Provide shims for gaps in headers.
Complete work and recall inspections.
** 4-way rough frame for kitchen approved by SY. Corrections for this 4-way are for laundry room and bathroom addition.
|
|