Permit No. B24-2293 Permit Type   RESIDENTIAL Site Address   37 CHEYENNE CIR
BERRY CREEK, CA 95916
Applied   09/12/2024 Applicant   RHONDA BERNDT DE PINEDA
Approved   11/01/2024 Owner   MORGAN JOHN W ETAL
Issued   11/01/2024 Contractor   MEDRANO GENERAL CONTRACTING
Parent Permit No.   Description   REPL MHI PFS (1600) 433A N.COMPLEX - CA RECOV
  Notes  
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

 12/03/2024BLOCKING/UNDERPINNINRANDALL SMITHPASS076011-01 - Scheduled by IVR.

 12/03/2024PERMANENT FOUNDATIONRANDALL SMITHPASS12/3/2024 4:56:27 PM XI 2 installed

 12/03/2024SETBACKSRANDALL SMITHPASS12/3/2024 4:56:31 PM Met setback requirements of the approved site plan

 01/21/2025UNDERGROUND CONDUITCHRISTOPHER ROBERTSPASS1/21/2025 12:45:00 PM Underground electrical conduit trench - Approved

 01/21/2025UNDERFLOOR PLUMBINGCHRISTOPHER ROBERTSFAIL1/21/2025 12:45:06 PM 1. Siding installed around entire perimeter of MH. Remove all the siding from the MH throughout so a proper underfloor plumbing inspection can be conducted. Complete work and recall inspection.

433APERMIT CENTERPASS

 02/11/2025ENV HEALTH RELEASEKATTY HERNANDEZPASSSEE NOTES11/1/2024 9:56:02 AM PENDING SEPTIC, EHS24-0293, FINAL APPROVAL. 2/11/2025 11:12:26 AM SEPTIC, EHS24-0293, RECEIVED FINAL APPROVAL.

 03/19/2025CAL FIRE FINAL INSPETROY HANDPASS3/13/2025 3:49:09 PM Need address on building. 3/19/2025 10:36:04 AM Applicant has made the corrections. Ok to final.

 03/20/2025**PERMIT FINALRANDALL SMITHFAILeTRAKiT Inspection Request3/19/2025 9:39:17 AM 3/19/2025 9:39 AM AMERICAN DREAM CONSTRUCTION INC Contact Name: AMERICAN DREAM CONSTRUCTION INC Site Address: 37 CHEYENNE CIR Phone: 5307200648 e-Mail: kdi.JOHNNY@gmail.com 3/24/2025 8:30:52 AM 1. Label the breakers in the main panel. 2. Water heater PTR drain must terminate between 6 inches and 18 inches from the ground.. repair replace or equal 3. Seal the top of the condenser disconnect box. 4. Paint all bare wood on the handrail. 5. Paint cover or equal all PVC piping on the exterior. 6. Provider vacuum breaker off the hose bib.. 7. Complete installation of exterior siding. 9. Provide a retaining wall or equal on the south facing slope. 10. Provide a continuity test.

 03/20/2025SEWER(PIPE/TEST/TAP)RANDALL SMITHPASS

 03/27/2025**PERMIT FINALCHRISTOPHER ROBERTSFAILeTRAKiT Inspection Request3/25/2025 4:02:03 PM 3/25/2025 4:02 PM AMERICAN DREAM CONSTRUCTION INC Contact Name: AMERICAN DREAM CONSTRUCTION INC Site Address: 37 CHEYENNE CIR Phone: 5307200648 e-Mail: kdi.JOHNNY@gmail.com 3/27/2025 12:03:56 PM 1. Obtain permit for retaining wall on south side of MH. ** All other corrections have been completed. ** Project can pass once retaining wall built and inspected by County.

RETAINING WALLDSINSPECTIONeTRAKiT Inspection Request5/8/2025 9:55:35 AM 5/8/2025 9:55 AM AMERICAN DREAM CONSTRUCTION INC Contact Name: AMERICAN DREAM CONSTRUCTION INC Site Address: 37 CHEYENNE CIR Phone: 5306802952 e-Mail: kdi.JOHNNY@gmail.com

RETAINING WALLSCOTT YOUNGeTRAKiT Inspection Request5/13/2025 7:18:02 AM 5/13/2025 7:18 AM AMERICAN DREAM CONSTRUCTION INC Contact Name: AMERICAN DREAM CONSTRUCTION INC Site Address: 37 CHEYENNE CIR Phone: 5306802952 e-Mail: kdi.JOHNNY@gmail.com