07/31/2025
3:08 AM

Butte County
Department of Development Services

Main: 530.552.3700
Automated Inspection Phone Line: 530.538.4365
Online Inspection Scheduling / Payments / Renewals:
ButteCounty.net/DDS

 
Permit No. B24-2228 Permit Type   RESIDENTIAL Site Address   33 SQUIRREL LN
BERRY CREEK, CA 95916
Applied   09/06/2024 Applicant   AMERICAN DREAM CONSTRUCTION INC
Approved   04/11/2025 Owner   LARSON BRENT E & AYELET ORION
Issued   04/15/2025 Contractor   AMERICAN DREAM CONSTRUCTION INC
Parent Permit No.   Description   REPL SFD(1201.4)GAR(427.8)COVD(92.5)PATIO(40)N.CMPX-def.trus
  Notes  
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

 04/22/2025UNDER SLAB PLUMBINGCHRISTOPHER ROBERTSPASSeTRAKiT Inspection Request4/21/2025 9:04:06 AM 4/21/2025 9:04 AM AMERICAN DREAM CONSTRUCTION INC Contact Name: AMERICAN DREAM CONSTRUCTION INC Site Address: 33 SQUIRREL LN Phone: 5306802952 e-Mail: kdi.JOHNNY@gmail.com 4/22/2025 4:11:24 PM Under slab plumbing - Approved

 04/24/2025UFER GROUNDWOODY TOWNSENDPASSeTRAKiT Inspection Request4/23/2025 8:47:33 AM 4/23/2025 8:47 AM AMERICAN DREAM CONSTRUCTION INC Can these inspections be set for PM? Thank you Contact Name: AMERICAN DREAM CONSTRUCTION INC Site Address: 33 SQUIRREL LN Phone: 5306802952 e-Mail: kdi.JOHNNY@gmail.com

 04/24/2025SETBACKSWOODY TOWNSENDPASSeTRAKiT Inspection Request4/23/2025 8:47:33 AM 4/23/2025 8:47 AM AMERICAN DREAM CONSTRUCTION INC Can these inspections be set for PM? Thank you Contact Name: AMERICAN DREAM CONSTRUCTION INC Site Address: 33 SQUIRREL LN Phone: 5306802952 e-Mail: kdi.JOHNNY@gmail.com

 04/24/2025PRE-SLABWOODY TOWNSENDPASSeTRAKiT Inspection Request4/23/2025 8:47:34 AM 4/23/2025 8:47 AM AMERICAN DREAM CONSTRUCTION INC Can these inspections be set for PM? Thank you Contact Name: AMERICAN DREAM CONSTRUCTION INC Site Address: 33 SQUIRREL LN Phone: 5306802952 e-Mail: kdi.JOHNNY@gmail.com

 04/24/2025FOUNDATION/FOOTINGSWOODY TOWNSENDPASSeTRAKiT Inspection Request4/23/2025 8:47:33 AM 4/23/2025 8:47 AM AMERICAN DREAM CONSTRUCTION INC Can these inspections be set for PM? Thank you Contact Name: AMERICAN DREAM CONSTRUCTION INC Site Address: 33 SQUIRREL LN Phone: 5306802952 e-Mail: kdi.JOHNNY@gmail.com

 05/07/2025SHEARWALL/B.W.P.-EXTWOODY TOWNSENDFAILeTRAKiT Inspection Request5/5/2025 11:00:19 AM 5/5/2025 11:00 AM AMERICAN DREAM CONSTRUCTION INC Contact Name: AMERICAN DREAM CONSTRUCTION INC Site Address: 33 SQUIRREL LN Phone: 5306802952 e-Mail: kdi.JOHNNY@gmail.com 5/7/2025 2:47:56 PM 1. Provide engineers fix for missing 2 STHD 14 at front patio, and 1 at wrong location at rear slider. 2. Provide engineers approval to replace HDU5 with STHD14 at back garage shear wall SW3. 3. Install H2.5 at bottom plate to king studs at windows and doors per SD1.0 4. Install MSTC60 at drag straps per S2.0/03. 5/14/2025 7:56:01 AM Engineers fix letter scanned to LF.

 05/07/2025ROOF FRAME/SHEATHINGWOODY TOWNSENDPASSeTRAKiT Inspection Request5/5/2025 11:00:19 AM 5/5/2025 11:00 AM AMERICAN DREAM CONSTRUCTION INC Contact Name: AMERICAN DREAM CONSTRUCTION INC Site Address: 33 SQUIRREL LN Phone: 5306802952 e-Mail: kdi.JOHNNY@gmail.com

SHEARWALL/B.W.P.-EXTDSINSPECTIONeTRAKiT Inspection Request5/8/2025 2:43:02 PM 5/8/2025 2:43 PM AMERICAN DREAM CONSTRUCTION INC Contact Name: AMERICAN DREAM CONSTRUCTION INC Site Address: 33 SQUIRREL LN Phone: 5306802952 e-Mail: kdi.JOHNNY@gmail.com

 05/13/2025SHEARWALL/B.W.P.-EXTCHRISTOPHER ROBERTSPASSeTRAKiT Inspection Request5/12/2025 7:26:09 AM 5/12/2025 7:26 AM AMERICAN DREAM CONSTRUCTION INC Contact Name: AMERICAN DREAM CONSTRUCTION INC Site Address: 33 SQUIRREL LN Phone: 5306802952 e-Mail: kdi.JOHNNY@gmail.com 5/13/2025 12:11:36 PM Prior corrections were completed. Shearwall ext. - Approved

 05/20/2025FIRE SPRINKLERSDSINSPECTIONVOIDeTRAKiT Inspection Request5/19/2025 8:19:46 AM 5/19/2025 8:20 AM AMERICAN DREAM CONSTRUCTION INC Contact Name: AMERICAN DREAM CONSTRUCTION INC Site Address: 33 SQUIRREL LN Phone: 5306802952 e-Mail: kdi.JOHNNY@gmail.com 5/20/2025 6:17:57 AM Fire sprinkler inspection added to fire sprinkler permit

 05/20/20254-WAY ROUGH FRAMECHRISTOPHER ROBERTSFAILeTRAKiT Inspection Request5/12/2025 7:27:17 AM 5/12/2025 7:27 AM AMERICAN DREAM CONSTRUCTION INC Contact Name: AMERICAN DREAM CONSTRUCTION INC Site Address: 33 SQUIRREL LN Phone: 5306802952 e-Mail: kdi.JOHNNY@gmail.com 5/20/2025 2:23:11 PM 1. Fill in mud sills with mortar or grout in garage. 2. Remove and replace all 6" Titan anchors installed below windows with a double bottom sill plate. Double bottom plate prevents 5/8 Titan anchors from proper 4" concrete embedment. 3. Seal off all holes and gang boxes to prevent rodent infestation. Complete work and recall inspection. ** okay to insulate and rock in areas without corrections.

 05/22/2025TAG ELECTRICCHRISTOPHER ROBERTSPASSeTRAKiT Inspection Request5/20/2025 5:40:10 PM 5/20/2025 5:40 PM AMERICAN DREAM CONSTRUCTION INC Contact Name: AMERICAN DREAM CONSTRUCTION INC Site Address: 33 SQUIRREL LN Phone: 5306802952 e-Mail: kdi.JOHNNY@gmail.com 5/22/2025 3:20:55 PM PGE electric tag issued by WT on 5/7/25

 05/22/20254-WAY ROUGH FRAMECHRISTOPHER ROBERTSPASSeTRAKiT Inspection Request5/20/2025 3:33:46 PM 5/20/2025 3:34 PM AMERICAN DREAM CONSTRUCTION INC Contact Name: AMERICAN DREAM CONSTRUCTION INC Site Address: 33 SQUIRREL LN Phone: 5306802952 e-Mail: kdi.JOHNNY@gmail.com 5/22/2025 3:20:58 PM Prior corrections have been completed. 4-way rough frame - Approved Okay to fully insulate and sheetrock

 06/04/2025ENV HEALTH RELEASEKATTY HERNANDEZPASSSEE NOTES4/9/2025 12:51:36 PM PENDING SEPTIC, EHS24-0271, FINAL APPROVAL. 6/4/2025 10:41:29 AM SEPTIC, EHS24-0271, RECEIVED FINAL APPROVAL.

 06/25/2025UNDERGROUND PLUMBINGCHRISTOPHER ROBERTSPASSeTRAKiT Inspection Request6/23/2025 6:59:05 AM 6/23/2025 6:59 AM AMERICAN DREAM CONSTRUCTION INC Contact Name: AMERICAN DREAM CONSTRUCTION INC Site Address: 33 SQUIRREL LN Phone: 5306802952 e-Mail: kdi.JOHNNY@gmail.com 6/25/2025 11:49:19 AM Underground plumbing - Approved

 06/25/2025UNDERGROUND WATER PICHRISTOPHER ROBERTSPASSeTRAKiT Inspection Request6/23/2025 6:56:53 AM 6/23/2025 6:56 AM AMERICAN DREAM CONSTRUCTION INC Contact Name: AMERICAN DREAM CONSTRUCTION INC Site Address: 33 SQUIRREL LN Phone: 5306802952 e-Mail: kdi.JOHNNY@gmail.com 6/25/2025 11:49:23 AM Underground water - Approved

 07/07/2025**PERMIT FINALCHRISTOPHER ROBERTSCANCELLEDeTRAKiT Inspection Request7/3/2025 5:25:04 PM 7/3/2025 5:25 PM AMERICAN DREAM CONSTRUCTION INC Contact Name: AMERICAN DREAM CONSTRUCTION INC Site Address: 33 SQUIRREL LN Phone: 5306802952 e-Mail: kdi.JOHNNY@gmail.com 7/7/2025 7:26:43 AM Cancelled per contractor

 07/09/2025**PERMIT FINALCHRISTOPHER ROBERTSCANCELLEDeTRAKiT Inspection Request7/7/2025 2:10:27 PM 7/7/2025 2:10 PM AMERICAN DREAM CONSTRUCTION INC Contact Name: AMERICAN DREAM CONSTRUCTION INC Site Address: 33 SQUIRREL LN Phone: 5306802952 e-Mail: kdi.JOHNNY@gmail.com 7/9/2025 7:33:41 AM Inspection canceled due to inspection scheduled on Wednesday 7/8/25

 07/15/2025CAL FIRE FINAL INSPETROY HANDPASS7/15/2025 11:56:27 AM Ok to final.

 07/15/2025**PERMIT FINALRANDALL SMITHFAIL7/15/2025 5:04:46 PM 1. Provide vehicle impact protection for the water heater in the garage or equal. 2. Provide completed energy calcs from CHEERS. 3. Provide final approval from Cal Fire. 4. Provide final approval from Butte County Environmental Health 5. Call for reinspection when corrections are completed. 7/16/2025 10:43:50 AM completed school fee form needed as well

SCHOOL FEE CERTIFICATION DUEPERMIT CENTEREMD TO APPLICANT

 07/16/2025**PERMIT FINALRANDALL SMITHPASS7/16/2025 4:24:17 PM All previous corrections were completed