| CAL FIRE FINAL INSPE | CHRIS BOYD | | | |
|
07/15/2024 | ENV HEALTH RELEASE | BC Land Use | NOT REQUIRED | | |
|
02/27/2025 | UNDER SLAB PLUMBING | RANDALL SMITH | PASS | 077276-05 - Scheduled by IVR. | |
|
02/27/2025 | UFER GROUND | RANDALL SMITH | PASS | 077276-04 - Scheduled by IVR. | |
|
02/27/2025 | PIER/COLUMN FOOTINGS | RANDALL SMITH | PASS | 077276-03 - Scheduled by IVR. | |
|
02/27/2025 | FOUNDATION/FOOTINGS | RANDALL SMITH | PASS | 077276-02 - Scheduled by IVR. | 2/27/2025 3:09:00 PM
All hold downs and anchor bolt spacing in place
|
|
02/27/2025 | SETBACKS | RANDALL SMITH | FAIL | 077276-01 - Scheduled by IVR. | 2/27/2025 3:09:10 PM
Revise site plan to show actual side setback of 6 ft.
Ok to pour
|
|
03/06/2025 | PRE-SLAB | RANDALL SMITH | PASS | 077360-01 - Scheduled by IVR. | 3/6/2025 5:33:00 PM
Ok to pour
3/6/2025 5:36:29 PM
Ok to pour
|
|
| SEWER DISTRICT FINAL | | | LOAPUD FINAL APPVL NEEDED | |
|
04/14/2025 | SHEARWALL/B.W.P.-EXT | RANDALL SMITH | FAIL | 10 am request - have to drive 2 hours | 4/10/2025 3:44:40 PM
call aleksey - 916-416-6976
4/14/2025 5:08:01 PM
Provide a letter of approval from the engineer of record for the Simpson Titens used in the shear walls.
Ok to dry in walls.
|
|
| SHEARWALL/B.W.P.-EXT | DSINSPECTION | | | |
|
04/25/2025 | SHEARWALL/B.W.P.-INT | SCOTT YOUNG | PASS | eTRAKiT Inspection Request | 4/18/2025 11:03:36 AM
4/18/2025 11:03 AM Aleksey Bgatov
Contact Name: Aleksey Bgatov
Site Address: 8 STEPPING STONE CT
Phone: 9164166976
e-Mail: abtilesac@yahoo.com
4/27/2025 5:12:48 PM
Letter from engineer in Attachments for Titans.
|
|
04/25/2025 | ROOF NAIL | SCOTT YOUNG | PASS | eTRAKiT Inspection Request | 4/18/2025 11:01:40 AM
4/18/2025 11:01 AM Aleksey Bgatov
Contact Name: Aleksey Bgatov
Site Address: 8 STEPPING STONE CT
Phone: 9164166976
e-Mail: abtilesac@yahoo.com
4/27/2025 5:12:52 PM
Roof nail -Approved.
Ok to cover.
|
|
06/03/2025 | ROUGH ELECTRICAL | CHRISTOPHER ROBERTS | CANCELLED | eTRAKiT Inspection Request | 6/2/2025 8:49:51 AM
6/2/2025 8:49 AM Aleksey Bgatov
Contact Name: Aleksey Bgatov
Site Address: 8 STEPPING STONE CT
Phone: 9164166976
e-Mail: abtilesac@yahoo.com
|
|
06/03/2025 | ROUGH FRAME | CHRISTOPHER ROBERTS | CANCELLED | eTRAKiT Inspection Request | 6/2/2025 8:47:24 AM
6/2/2025 8:47 AM Aleksey Bgatov
Contact Name: Aleksey Bgatov
Site Address: 8 STEPPING STONE CT
Phone: 9164166976
e-Mail: abtilesac@yahoo.com
|
|
06/03/2025 | ROUGH MECHANICAL | CHRISTOPHER ROBERTS | CANCELLED | eTRAKiT Inspection Request | 6/2/2025 8:49:03 AM
6/2/2025 8:49 AM Aleksey Bgatov
Contact Name: Aleksey Bgatov
Site Address: 8 STEPPING STONE CT
Phone: 9164166976
e-Mail: abtilesac@yahoo.com
|
|
06/03/2025 | ROUGH PLUMBING | CHRISTOPHER ROBERTS | CANCELLED | eTRAKiT Inspection Request | 6/2/2025 8:48:17 AM
6/2/2025 8:48 AM Aleksey Bgatov
Contact Name: Aleksey Bgatov
Site Address: 8 STEPPING STONE CT
Phone: 9164166976
e-Mail: abtilesac@yahoo.com
|
|
06/03/2025 | STUCCO (LATH) | CHRISTOPHER ROBERTS | FAIL | eTRAKiT Inspection Request | 6/2/2025 8:52:15 AM
6/2/2025 8:52 AM Aleksey Bgatov
Contact Name: Aleksey Bgatov
Site Address: 8 STEPPING STONE CT
Phone: 9164166976
e-Mail: abtilesac@yahoo.com
6/3/2025 11:17:03 AM
1. Provide a 1" gap between foam backer and weep screed throughout entire perimeter. Foam backer is currently resting on top of weep screed.
Complete work and recall inspection.
|
|
06/03/2025 | 4-WAY ROUGH FRAME | CHRISTOPHER ROBERTS | FAIL | eTRAKiT Inspection Request | 6/2/2025 8:50:38 AM
6/2/2025 8:50 AM Aleksey Bgatov
Contact Name: Aleksey Bgatov
Site Address: 8 STEPPING STONE CT
Phone: 9164166976
e-Mail: abtilesac@yahoo.com
6/3/2025 11:17:07 AM
1. 4-way inspection not conducted due to no fire sprinkler permit being submitted and approved. A complete fire sprinkler system installed in home without a plan checked permit.
** Submit Fire plans to county and apply for fire sprinkler permit.
Complete Sprinkler permit approval and recall 4-way.
|
|
| STUCCO (LATH) | RANDALL SMITH | | eTRAKiT Inspection Request | 6/16/2025 11:05:34 AM