04/22/2024 | ROUGH FRAME | SCOTT YOUNG | FAIL | jason 530-815-1084 | 4/19/2024 2:09:44 PM
4/19/2024 2:09 PM James Casebeer
am/am please
Contact Name: James Casebeer
Site Address: 1763 18TH ST
Phone: 5308910333
e-Mail: jamescasebeer@crbr.com
4/23/2024 6:26:44 AM
Not ready for 4 way rough frame, whisk is the next inspection required.
Plans do not call for shearwall.
Rough plumbing
Rough electrical
Rough mechanical
Rough frame not ready at this time.
Stub out all DWV Pipes through roof. Have DWV under test.
Run exhaust fan ductwork.
|
|
04/22/2024 | ROOF FRAME/SHEATHING | SCOTT YOUNG | FAIL | jason 530-815-1084 | 4/19/2024 2:09:44 PM
4/19/2024 2:09 PM James Casebeer
am/am please
Contact Name: James Casebeer
Site Address: 1763 18TH ST
Phone: 5308910333
e-Mail: jamescasebeer@crbr.com
4/23/2024 6:26:51 AM
Not ready for roof frame / nail.
1. None of the H-1 or H-2.5's installed as per plans.
Contractor wants to use Simpson timber locks,these have not been installed at this time either.
2. None of the DWV roof penetrations have been done .
3. Exhaust fan ducting not roughed in.
|
|
07/22/2024 | 4-WAY ROUGH FRAME | WOODY TOWNSEND | FAIL | pm pm please | 7/18/2024 11:34:02 AM
7/18/2024 11:34 AM James Casebeer
jason 530-815-1084
Contact Name: James Casebeer
Site Address: 1763 18TH ST
Phone: 5308910333
e-Mail: jamescasebeer@crbr.com
7/22/2024 4:07:46 PM
1. Repair over bored studs at kitchen sink, master bath and laundry plumbing.
2. Test ABS.
3. Install all hvac ducts.
4. Install nail protection at master bath shower vent.
5. Move master bed smoke detector to within 12" of highest point of ceiling.
|
|
08/01/2024 | 4-WAY ROUGH FRAME | RANDALL SMITH | FAIL | PM PLEASE | 8/1/2024 4:23:40 PM
1. Repair over bored studs at master bath.
2. Test ABS.
3. Cover all hvac ducts registers.
4. Strap all DWV piping midway up.
5. Complete installation of exhaust fans.
6. Cover all holes in the bottom plate and floor.
7. Complete sub floor in the hallway bathroom.
8. Remove all abandoned conductors.
9. Repair, replace or equal bottom plate at the main panel.
10. Call for reinspection when all corrections are completed.
|
|
08/07/2024 | 4-WAY ROUGH FRAME | CHRISTOPHER ROBERTS | PASS | pm /pm please | 8/6/2024 10:59:11 AM
8/6/2024 10:59 AM James Casebeer
jason 530-815-1084
.
Contact Name: James Casebeer
Site Address: 1763 18TH ST
Phone: 5308910333
e-Mail: jamescasebeer@crbr.com
8/7/2024 3:00:28 PM
Prior corrections have been completed.
4-way rough frame - Approved
|
|
08/08/2024 | PGE ELECTRIC TAG | CHRISTOPHER ROBERTS | PASS | | 8/8/2024 9:49:45 AM
PGE electric tag - issued
|
|
09/26/2024 | SHOWER PAN/TUB TEST | SCOTT YOUNG | PASS | eTRAKiT Inspection Request | 9/23/2024 3:09:32 PM
9/23/2024 3:09 PM James Casebeer
am/am please
Contact Name: James Casebeer
Site Address: 1763 18TH ST
Phone: 5308910333
e-Mail: jamescasebeer@crbr.com
9/23/2024 3:10:11 PM
9/23/2024 3:10 PM James Casebeer
am/am please
Contact Name: James Casebeer
Site Address: 1763 18TH ST
Phone: 5308910333
e-Mail: jamescasebeer@crbr.com
9/27/2024 6:36:54 AM
Shower pan -Approved
9/27/2024 6:39:29 AM
Shower pan -Approved
|
|
10/03/2024 | PGE GAS TAG | RANDALL SMITH | PASS | | |
|
12/11/2024 | **PERMIT FINAL | SCOTT YOUNG | CANCELLED | AM Request | 12/11/2024 7:12:03 PM
Cancelled by contractor.
|
|
| **PERMIT FINAL | DSINSPECTION | | eTRAKiT Inspection Request | 12/13/2024 4:13:34 PM
12/13/2024 4:13 PM James Casebeer
Am inspection Please
Contact Name: James Casebeer
Site Address: 1763 18TH ST
Phone: 5308910333
e-Mail: jamescasebeer@crbr.com
3/11/2025 8:24:04 AM
3/11/2025 8:23 AM James Casebeer
Contact Name: Robert Mackenzie
Site Address: 2684 Hwy 32 suite 100
Phone: 5309612229
e-Mail: Robertmackenzie@crbr.com
|
|
12/16/2024 | **PERMIT FINAL | CHRISTOPHER ROBERTS | CANCELLED | eTRAKiT Inspection Request | 12/11/2024 10:14:51 AM
12/11/2024 10:14 AM James Casebeer
after 12:00pm please.
Contact Name: Robert Mackenzie
Site Address: 2684 Hwy 32 suite 100
Phone: 5309612229
e-Mail: Robertmackenzie@crbr.com
12/16/2024 9:23:30 AM
croberts changed Inspection Date/Time from 12/16/2024 12:00 PM to 12/16/2024 11:00 AM
12/16/2024 1:18:35 PM
Not ready for permit final.
|
|
| **PERMIT FINAL | DSINSPECTION | | | |
|
02/11/2025 | **PERMIT FINAL | RANDALL SMITH | FAIL | eTRAKiT Inspection Request | 2/6/2025 2:45:27 PM
2/6/2025 2:45 PM James Casebeer
Contact Name: Robert Mackenzie
Site Address: 2684 Hwy 32 suite 100
Phone: 5309612229
e-Mail: Robertmackenzie@crbr.com
2/11/2025 3:59:27 PM
1 Provide an anti tip device on the stove.
2. Remove washing machine to allow inspection of gfci outlet. Provide gfci outlet if not installed.
3. Smoke detectors are not working in test mode. Repair ,replace or equal.
4. Provide chalking around the bottom of the water closets.
5. Provide vacancy sensors in bathrooms and laundry room. Sheet 5 Lighting
6. Provide humidistats in the bathrooms or provide listing data showing humidistat's are installed in the exhaust fan.
7. Paint,cover or equal condensation line on the roof.
8. Provide drip edge flashing on all eave boards.
9. Provide a gfci service outlet at the same level as the roof mounted unit.
10. Identify 50 amp breaker that is not hooked up in main panel.
11. Remove all solar related warning labels from the main panel.
12. Provide a gas bond.
13. Call for reinspection when corrections are completed.
Note. House was occupied at time of final inspection
|
|
03/14/2025 | **PERMIT FINAL | WOODY TOWNSEND | PASS | eTRAKiT Inspection Request | 3/7/2025 11:30:15 AM
3/7/2025 11:30 AM James Casebeer
Contact Name: Robert Mackenzie
Site Address: 2684 Hwy 32 suite 100
Phone: 5309612229
e-Mail: Robertmackenzie@crbr.com
3/11/2025 2:45:25 PM
3/11/2025 2:45 PM James Casebeer
Contact Name: Robert Mackenzie
Site Address: 2684 Hwy 32 suite 100
Phone: 5309612229
e-Mail: Robertmackenzie@crbr.com
3/11/2025 2:50:16 PM
3/11/2025 2:50 PM James Casebeer
Contact Name: Robert Mackenzie
Site Address: 2684 Hwy 32 suite 100
Phone: 5309612229
e-Mail: Robertmackenzie@crbr.com
|
|