Permit No. B24-0129 Permit Type   NRES NON RESIDENTIAL Site Address   1023 NEAL RD
PARADISE, CA 95969
Applied   01/22/2024 Applicant   CRAIG CISSEL - GENERAL SERVICES
Approved   01/31/2025 Owner   COUNTY OF BUTTE
Issued   02/03/2025 Contractor   CRAIG CISSEL - GENERAL SERVICES
Parent Permit No.   Description   SCALE HOUSE(118) 1500-GAL GRND HOLDNG TANK, 1K-GAL H20 TANK
  Notes  
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

 02/29/2024FIRE MARSHAL CLEARANCHRIS BOYDVOIDVOIDED (CCB2 2/29/2024)2/29/2024 3:10:08 PM Fire inspection is not required and ok to refund fees 2/29/2024 3:10:16 PM Inspection voided by CCB2.

 04/28/2025UNDER SLAB PLUMBINGSCOTT YOUNGPASS078169-01 - Scheduled by IVR.4/29/2025 6:12:14 AM Underslab plumbing and electrical (partial , only bathroom area looked at , septic tank not installed.)

 04/30/2025FOUNDATION/FOOTINGSCHRISTOPHER ROBERTSPASS078235-01 MSG! -Msg! Scheduled by IVR.4/30/2025 12:58:35 PM Foundation/footings - Approved

 04/30/2025UNDERGROUND ELECTRICCHRISTOPHER ROBERTSPASS4/30/2025 12:58:42 PM Underground electric - Approved

 05/12/2025PIER/COLUMN FOOTINGSSCOTT YOUNGPASS078394-01 - Scheduled by IVR.5/12/2025 6:13:47 AM Pier column footings-Approved Light pole footings and small curb between scale and bldg.- Approved

 05/13/2025ROOF NAILWOODY TOWNSENDPASS078475-01 MSG! -Msg! Scheduled by IVR.

 05/21/20254-WAY ROUGH FRAMEWOODY TOWNSENDPASS078596-01 - Scheduled by IVR.

 05/13/2025SHEARWALL/B.W.P.-EXTWOODY TOWNSENDPASS5/13/2025 4:01:09 PM Provide SI report for epoxied anchors and install HD and DTZ hardware. Exterior nail okay to cover. 5/28/2025 4:27:19 PM SI report received and hardware installed.

 05/29/2025SHEARWALL/B.W.P.-INTWOODY TOWNSENDCANCELLED

 07/09/2025FIRE MARSHAL CLEARANCHRIS BOYDPASS7/9/2025 1:10:34 PM Ok to final.

 07/09/2025**PERMIT FINALRANDALL SMITHFAIL079283-01 MSG! -Msg! Scheduled by IVR.7/9/2025 2:50:19 PM 1. Provide a maximum 15 amp breaker for the mini split or equal. 2. Provide a RFI for booster pump and listing showing maximum breaker size. 3. Label all electrical outlets. 4. Provide a working water heater. 5. Provide screen guards in the gutters or equal. 6. Provide final approval from Butte County Environmental Health. 7. Provide fina approval from Butte County Public Works NPDES. 8. Provide final approval from Cal Fire. 9. Provide required certificates of acceptance: NCRA-ENV-02-A, NCRA-LTI-02-A, NCRA-MCH-02-A, NCRA-MCH-03-A. 10. Provide all required special inspection reports. 11. Call for reinspection when corrections are completed. Surveillance equipment is not installed at this time. Contractor states this is a responsibility of the county not the contractor.. Scott@slaterandson.com

 07/10/2025ENV HEALTH RELEASEKATTY HERNANDEZPASSSee Notes4/3/2024 2:00:02 PM PENDING SEPTIC, EHS22-0322, FINAL APPROVAL. 7/10/2025 8:25:41 AM Septic Tank has been finaled.

 07/15/2025**PERMIT FINALRANDALL SMITHPASS079373-01 - Scheduled by IVR.7/15/2025 5:04:40 PM All previous corrections were completed

 07/17/2025LAND DEV FINALPWLANDDEVPASS