Permit No. B23-2125 Permit Type   RESIDENTIAL Site Address   4122 HIDDEN VALLEY RD
BUTTE VALLEY, CA 95965
Applied   06/29/2023 Applicant   SENAT SIMONE GEULA LIVING TRUST
Approved   07/05/2024 Owner   SENAT SIMONE GEULA LIVING TRUST
Issued   07/08/2024 Contractor   OB
Parent Permit No.   Description   REPL SFD(2057) GAR(816) COVD+BRZWY(1173) CAMP FIRE
  Notes   camp fire rebuild
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

 07/12/2024FOUNDATION/FOOTINGSCHRISTOPHER ROBERTSPASS7/12/2024 12:24:41 PM Foundation/footings - Approved

 07/11/2024UNDER SLAB PLUMBINGSCOTT YOUNGFAIL7/12/2024 3:29:19 PM Abs not holding under test , filled at 9:30 in the morning, at 1:30 that day it was down 8' All pipe joints have been covered with gravel . Unable to see joints. Clear all joints and refill for next inspection.

 07/11/2024FOUNDATION/FOOTINGSSCOTT YOUNGPARTIAL7/12/2024 3:29:27 PM Footing and foundation approved but pre slab failed.

 07/16/2024UNDER SLAB PLUMBINGSCOTT YOUNGFAIL7/16/2024 1:05:14 PM Not ready 7/16/2024 2:46:19 PM Not ready

 07/18/2024UNDER SLAB PLUMBINGRICHARD PRATTPASS7/18/2024 3:25:40 AM rpratt changed Inspection Date/Time from 07/18/2024 08:00 AM to 07/18/2024 09:30 AM 7/18/2024 10:15:12 AM Under slab plumbing- Approved by CRoberts 7.12.24

 07/18/2024PRE-SLABRICHARD PRATTPASS7/18/2024 5:50:21 PM Pre pour slab sod and garage - Approved 7/22/2024 5:20:53 AM Pre pour slab sod and garage - Approved

 07/18/2024SETBACKSRICHARD PRATTPASS7/18/2024 5:50:34 PM Setbacks - checked and Approved 7/22/2024 5:21:06 AM Setbacks - checked and Approved

 08/22/2024SHEARWALL/B.W.P.-EXTSCOTT YOUNGPASS8/22/2024 6:28:10 AM Exterior shearwall-Approved

 08/22/2024ROOF NAILSCOTT YOUNGPASS8/22/2024 6:28:20 AM Roof nail-Approved

 09/13/2024PROGRESS INSPECTIONSCOTT YOUNGPASS9/17/2024 8:43:59 AM This inspection was for soffit framing, electrical placed in the soffit, prior to them closing it up to where it would not be accessible.

 09/23/20244-WAY ROUGH FRAMEWOODY TOWNSENDFAIL074817-01 - Scheduled by IVR.9/23/2024 4:51:46 PM 1. Provide County Stamped approved plans. 2. Connect all moister exhaust ducts to fans. 3. Cover all HVAC registers. Laundry and kitchen. 4. Provide mid support for pvc condensate lines. 5. Clarify kitchen counter receptacle spacing requirements at kitchen sink. Receptacles shall be within 2' of all counter top edges including sink break. 6. Support Fire place conductor. 7. Complete circuits above kitchen island. Install elec. box. 8. Bond all metal electrical outlet boxes including exterior. 9. Install feeders to sub panel. 10. Install clean out at garage sink. 11. Wire exterior receptacle within 25' of AC condenser. 12. Install doors around fire place. 13. Complete electrical circuit to attic HVAC unit. 14. Frame attic access. 15. Provide approved revised Fire sprinkler plans for additional sprinkler heads in great room and loft. Inspection not complete without approved and revised plans.

 10/04/20244-WAY ROUGH FRAMERICHARD PRATTFAIL10/4/2024 5:37:29 AM rpratt changed Inspection Date/Time from 10/04/2024 08:00 AM to 10/04/2024 08:30 AM 10/4/2024 1:00:18 PM 1. Provide pressure blocking between the studs backing up to the truss side pressure blocks or equal. As per details 6, 7, & 9 on S2 & S5. 2. All previous correction items have been completed. 3. Recall inspection when the above is completed.

 10/08/20244-WAY ROUGH FRAMERICHARD PRATTPASS10/8/2024 6:19:21 AM rpratt changed Inspection Date/Time from 10/08/2024 08:00 AM to 10/08/2024 10:30 AM 10/8/2024 9:22:29 PM 4way frame and trades - Approved

 12/23/2024SHOWER PAN/TUB TESTWOODY TOWNSENDPASS076344-01 - Scheduled by IVR.12/23/2024 3:55:28 PM 2 shower pans in dwelling approved

 12/23/2024UNDERGROUND CONDUITWOODY TOWNSENDPASS

 12/23/2024UNDERGROUND WATER PIWOODY TOWNSENDPASS

 01/17/2025GAS TESTCHRISTOPHER ROBERTSPASS1/17/2025 2:27:50 PM Gas test for house line - Approved

 01/17/2025GAS PIPINGCHRISTOPHER ROBERTSPASS076673-01 - Scheduled by IVR.1/17/2025 2:27:29 PM 1. Poly gas line installed on 1/16/25 by propane company. Homeowner stated that gas line was filled after installation of tank. PSI gauge is currently at 0 PSI. Repair leak in poly gas line. 1/22/2025 7:18:19 AM Gas line was repaired. Gas piping/trench - Approved 1/22/25 CR

 01/22/2025GAS TESTCHRISTOPHER ROBERTSCANCELLED1/22/2025 11:19:09 AM Gas test inspection conducted on 1/17/25

 01/23/2025SHOWER PAN/TUB TESTWOODY TOWNSENDPASS076749-02 - Scheduled by IVR.1/23/2025 5:06:27 PM Garage shower pan approved

 11/21/2024ENV HEALTH RELEASEDANIEL GRATTANPASS11/21/2024 1:12:37 PM PENDING DISINFECTION OF WELL, TOTAL COLIFORM OVER 200 1/24/2025 3:44:42 PM Hi Simone, This is in response to your voicemail. If you take a look at your well results, you can see that the total coliform is over 200 mg/L which fails drinking water standards. It is rare when we see it that high. When we have a sample like this, we require the well to be disinfected and be sampled twice and have two consecutive negative tests. Let me know if you have any other questions for this process. Thank you, Danny Grattan Environmental Health Specialist I Public Health | Butte County, CA 202 Mira Loma Drive | Oroville, CA 95965 T: 530.552.4028 | F:530.538.5339 2/6/2025 8:01:01 AM Received two passing results for total coliform and e. coli.

 02/20/2025GAS PIPINGCHRISTOPHER ROBERTSCANCELLED2/20/2025 9:20:01 AM Canceled per homeowner

 01/24/2025CAL FIRE FINAL INSPECHRIS BOYDPASS1/24/2025 12:58:46 PM Post address on structure per our requirements. Left a VM with Simone as well as a business card onsite to notify her. 2/26/2025 8:46:13 AM Owner forwarded photos of posted address

 02/27/2025GAS PIPINGCHRISTOPHER ROBERTSPASS2/27/2025 2:53:43 PM Gas piping stove - Approved

 04/22/2025**PERMIT FINALSCOTT YOUNGCANCELLED078102-01 - Scheduled by IVR.4/22/2025 7:57:33 PM Spoke with Simone, the owner builder, HERS REPORT has not been done. All appliances have been removed from the house to install floors. Call for final when completed.

 05/13/2025**PERMIT FINALWOODY TOWNSENDPASS