Permit No. B23-1719 Permit Type   MISCELLANEOUS Site Address   15462 NOPEL AVE
FOREST RANCH, CA 95942
Applied   05/23/2023 Applicant   CLEANRITE INC
Approved   07/21/2023 Owner   WHIPPLE TIMOTHY A & SHELLY
Issued   07/26/2023 Contractor   OB
Parent Permit No.   Description   REMODEL REPAIR (1894) GAR (460)-TREE DMG
  Notes  
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

 05/09/2024FOUNDATION/FOOTINGSCHRISTOPHER ROBERTSPASSam/am please5/7/2024 1:02:26 PM 5/7/2024 1:02 PM James Casebeer jason 530-815-1084 Contact Name: James Casebeer Site Address: 15462 NOPEL AVE Phone: 5308910333 e-Mail: jamescasebeer@crbr.com 5/9/2024 2:39:44 PM Foundation/footings - Approved

 08/02/2024ROOF FRAME/SHEATHINGSCOTT YOUNGPARTIALeTRAKiT Inspection Request7/31/2024 11:59:15 AM 7/31/2024 11:59 AM James Casebeer am/am please Contact Name: James Casebeer Site Address: 15462 NOPEL AVE Phone: 5308910333 e-Mail: jamescasebeer@crbr.com 8/2/2024 11:17:09 AM Roof frame/ Nail Inspection was done with a unapproved large set of plans , an 8x 11 set with the stamp but barely legible due to weather m sun and water. The truss calc's that were left onsite were not stamped or approved. Tried calling the contractor but reception was not good and call was dropped. Contractor's son showed up and I explained what was going on and showed him what was left. He told me he understood the problem and would relay the issue. The inspection was done with an unapproved set of plans , they were instructed to have the stamped set onsite at next inspection, they can cover the roof at there risk . If approved set matches set that was left onsite, good.

 08/22/20244-WAY ROUGH FRAMERICHARD PRATTCANCELLEDCancelled- not Tues or Thur8/22/2024 8:02:58 PM Cancelled due to not being a Tuesday or Thursday. Email sent and in chronology.

 08/27/20244-WAY ROUGH FRAMECHRISTOPHER ROBERTSFAILjason 530-815-*10848/14/2024 11:51:29 AM 8/14/2024 11:51 AM James Casebeer am/am please Contact Name: James Casebeer Site Address: 15462 NOPEL AVE Phone: 5308910333 e-Mail: jamescasebeer@crbr.com 8/27/2024 2:58:30 PM 1. Fill in gap for plumbing under the bathtub upstairs. 2. Seal off all holes leading to bottom story and outside. 3. Secure jack studs for window frame in master bedroom. 4. Cover gap for HVAC duct running through floor and provide fire blocking for dead space. 5. Finish running gas line to HVAC. 6. Cover all HVAC registers. Complete work and call for re-inspection. ** roof nail - Approved ** truss calcs match ones used on prior inspection.

 08/29/20244-WAY ROUGH FRAMERICHARD PRATTFAIL W/RE-INSP FEEeTRAKiT Inspection Request8/28/2024 1:12:22 PM 8/28/2024 1:12 PM James Casebeer am Contact Name: James Casebeer Site Address: 15462 NOPEL AVE Phone: 5308910333 e-Mail: jamescasebeer@crbr.com 8/29/2024 6:08:54 AM rpratt changed Inspection Date/Time from 08/29/2024 08:00 AM to 08/29/2024 10:00 AM 8/29/2024 11:18:17 AM 1. Complete the fire stop draft stop at the top of the HVAC chase in the bedroom. 2. Complete the building wrap with a weatherproof barrier, building paper or equal. 3. Complete the deck, framing and call for inspection when completed if it hasn't already been inspected no notes in Track-it. 4. Provide a sediment trap for the FAU in the attic. 5. Pay the Re-inspection fee and Recall inspection when completed

 09/12/20244-WAY ROUGH FRAMESCOTT YOUNGFAILJASON 530-815-10849/11/2024 11:41:07 AM 9/11/2024 11:41 AM James Casebeer PM/PM PLEASE Contact Name: James Casebeer Site Address: 15462 NOPEL AVE Phone: 5308910333 e-Mail: jamescasebeer@crbr.com 9/13/2024 6:11:16 AM 1. Pay reinspection fee 2. All corrections from previous inspection have been completed 3. Lathe inspection failed, doors not set or trimmed Penetrations have not been seal. Meter release tag issued.

 09/19/2024TAG ELECTRICSCOTT YOUNGPASS

 09/19/2024SHEARWALL/B.W.P.-INTSCOTT YOUNGFAILeTRAKiT Inspection Request9/17/2024 7:48:38 AM 9/17/2024 7:48 AM James Casebeer am/am please Contact Name: James Casebeer Site Address: 15462 NOPEL AVE Phone: 5308910333 e-Mail: jamescasebeer@crbr.com 9/20/2024 2:00:32 PM Four way rough frame was not passed. Spoke with Jason about lathe not passing, doors had not been set and lathe not completed. All penetration's had not been sealed. He asked if he could seal them from the inside,I explained we needed to be able to verify from the outside of the building that it was properly sealed. I did say he could seal from the inside if he would like and he guaranteed that. Doors have been set at this time but lathe has not been completed in areas around the door and unable to verify caulk or foam from inside due to the fact they have already put sheet rock up,this should not have been done until 4 way has passed. At inspection of penetration from outside the outside it appears nothing has been done in numerous areas. Interior shearwall is a fail as they have not met the min. Requirements as stated on the plans of 7 edge and field. Located on page 7 of the plans. Generally interior shearwall is placed vertically,bottom plate to top plate. Although, In section 2306.3 there is no difference if it is blocked at all edges. Neither was done , along with nailing schedule not being compliant.

 09/26/2024SHEARWALL/B.W.P.-INTCHRISTOPHER ROBERTSFAILeTRAKiT Inspection Request9/23/2024 3:08:27 PM 9/23/2024 3:08 PM James Casebeer am/am please Contact Name: James Casebeer Site Address: 15462 NOPEL AVE Phone: 5308910333 e-Mail: jamescasebeer@crbr.com 9/26/2024 2:51:35 PM 1. Nailing pattern on plans call for 7" edge 7" field for interior Shearwall. Nailing on wall in main living room east wall and wall in far bedroom safe room is too wide. Complete work and call for a re-inspection.

 09/27/2024STUCCO (LATH)ADAM KINGSLEYPASS9/27/2024 2:07:23 PM Previous Stucco/Lath Inspection corrections cleared or not required. Ok to proceed with Stucco Installation.

 09/26/2024STUCCO (LATH)CHRISTOPHER ROBERTSPASSeTRAKiT Inspection Request9/23/2024 3:08:27 PM 9/23/2024 3:08 PM James Casebeer am/am please Contact Name: James Casebeer Site Address: 15462 NOPEL AVE Phone: 5308910333 e-Mail: jamescasebeer@crbr.com 10/3/2024 6:26:26 AM Stucco(lath) - Approved

 10/03/2024SHEARWALL/B.W.P.-INTCHRISTOPHER ROBERTSPASS10/3/2024 3:12:09 PM Shearwall int. - Approved Prior corrections have been completed.

 10/15/2024SHOWER PAN/TUB TESTCHRISTOPHER ROBERTSPASSBob Mackenzie (530)961-222910/9/2024 1:44:39 PM 10/9/2024 1:44 PM James Casebeer am please Contact Name: James Casebeer Site Address: 15462 NOPEL AVE Phone: 5308910333 e-Mail: jamescasebeer@crbr.com 10/15/2024 11:41:54 AM Shower pan/tub test - Approved

**PERMIT FINALDSINSPECTIONeTRAKiT Inspection Request12/10/2024 1:00:25 PM 12/10/2024 1:00 PM James Casebeer 4 way inspection needed. electrical, plumbing,hvac,gas. occupancy inspection. Contact Name: Robert Mackenzie Site Address: 2684 Hwy 32 suite 100 Phone: 5309612229 e-Mail: Robertmackenzie@crbr.com

SMOKE DETECTORSDSINSPECTIONeTRAKiT Inspection Request12/10/2024 1:00:25 PM 12/10/2024 1:00 PM James Casebeer 4 way inspection needed. electrical, plumbing,hvac,gas. occupancy inspection. Contact Name: Robert Mackenzie Site Address: 2684 Hwy 32 suite 100 Phone: 5309612229 e-Mail: Robertmackenzie@crbr.com

SITE UTILITIESDSINSPECTIONeTRAKiT Inspection Request12/10/2024 1:00:25 PM 12/10/2024 1:00 PM James Casebeer 4 way inspection needed. electrical, plumbing,hvac,gas. occupancy inspection. Contact Name: Robert Mackenzie Site Address: 2684 Hwy 32 suite 100 Phone: 5309612229 e-Mail: Robertmackenzie@crbr.com

 12/10/2024GAS TESTSCOTT YOUNGPASSeTRAKiT Inspection Request12/4/2024 3:13:36 PM 12/4/2024 3:13 PM Robert Mackenzie Contact Name: Robert Mackenzie Site Address: 15462 NOPEL AVE Phone: 5309612229 e-Mail: Robertmackenzie@crbr.com 12/11/2024 5:41:33 AM House gas test LPG tank , propane line - both Approved.

 12/12/2024WATER SERVICECHRISTOPHER ROBERTSPASSeTRAKiT Inspection Request12/10/2024 1:00:25 PM 12/10/2024 1:00 PM James Casebeer 4 way inspection needed. electrical, plumbing,hvac,gas. occupancy inspection. Contact Name: Robert Mackenzie Site Address: 2684 Hwy 32 suite 100 Phone: 5309612229 e-Mail: Robertmackenzie@crbr.com 12/12/2024 3:03:41 PM Water service for reconnect to tank - Approved

 12/12/2024FIREPLACECHRISTOPHER ROBERTSPASSeTRAKiT Inspection Request12/10/2024 1:00:26 PM 12/10/2024 1:00 PM James Casebeer 4 way inspection needed. electrical, plumbing,hvac,gas. occupancy inspection. Contact Name: Robert Mackenzie Site Address: 2684 Hwy 32 suite 100 Phone: 5309612229 e-Mail: Robertmackenzie@crbr.com 12/12/2024 3:03:44 PM Fireplace - Approved

 12/19/2024**PERMIT FINALSCOTT YOUNGFAILeTRAKiT Inspection Request12/16/2024 4:43:34 PM 12/16/2024 4:43 PM James Casebeer Contact Name: Robert Mackenzie Site Address: 2684 Hwy 32 suite 100 Phone: 5309612229 e-Mail: Robertmackenzie@crbr.com 12/19/2024 5:45:13 PM 1. Humistats not working in both upstairs bathrooms. 2. Front and back decks not finished. 3. Blank cover required in laundry room sub panel.. 4. Anti-syphon device on all exterior hose bibs. 5. Cover electrical junction box in downstairs storage. 6. Contrasting house address numbers on the home. 7. Hers report required

 02/27/2025FOUNDATION/FOOTINGSSCOTT YOUNGPASSeTRAKiT Inspection Request2/20/2025 1:51:08 PM 2/20/2025 1:51 PM James Casebeer Contact Name: Robert Mackenzie Site Address: 2684 Hwy 32 suite 100 Phone: 5309612229 e-Mail: Robertmackenzie@crbr.com 2/24/2025 9:15:41 AM 2/24/2025 9:15 AM James Casebeer Contact Name: Robert Mackenzie Site Address: 2684 Hwy 32 suite 100 Phone: 5309612229 e-Mail: Robertmackenzie@crbr.com 2/28/2025 6:23:54 AM Place dobies under rebar matting prior to pour. Take pictures of corrections

 06/24/2025FORMS/STEEL/HOLDOWNSSCOTT YOUNGPASSeTRAKiT Inspection Request6/20/2025 3:30:08 PM 6/20/2025 3:30 PM BILLSON CONSTRUCTION COMPANY INC Contact Name: BILLSON CONSTRUCTION COMPANY INC Site Address: 15462 NOPEL AVE Phone: 5303432293 e-Mail: brody@billsonconstruction.com 6/25/2025 5:33:21 AM Small footing at back deck -Approved

 07/15/2025**PERMIT FINALSCOTT YOUNGPASSeTRAKiT Inspection Request7/9/2025 3:16:53 PM 7/9/2025 3:16 PM BILLSON CONSTRUCTION COMPANY INC Contact Name: BILLSON CONSTRUCTION COMPANY INC Site Address: 15462 NOPEL AVE Phone: 5303432293 e-Mail: brody@billsonconstruction.com 7/16/2025 7:46:30 AM All previous corrections have been completed. Ok to final . 7/16/2025 7:47:32 AM All previous corrections have been completed. Ok to final . 7/16/2025 7:48:25 AM All previous corrections have been completed. Ok to final . 7/16/2025 7:49:42 AM All previous corrections have been completed. Ok to final . 7/16/2025 7:50:41 AM All previous corrections have been completed. Ok to final .