04/30/2024 | SETBACKS | RICHARD PRATT | FAIL W/RE-INSP FEE | | 4/30/2024 11:33:04 AM
Contractor not ready for inspection and did not cancel ahead of time.
Pay re-inspection fee and recall the inspection when ready.
4/30/2024 12:54:05 PM
Contractor not ready for inspection and did not cancel ahead of time.
Pay re-inspection fee and recall the inspection when ready.
|
|
04/30/2024 | UNDERGROUND ELECTRIC | RICHARD PRATT | CANCELLED | eTRAKiT Inspection Request | 4/22/2024 2:20:24 PM
4/22/2024 2:20 PM FREEDOM FOREVER LLC
AM if possible
Contact Name: FREEDOM FOREVER LLC
Site Address: 1347 7TH ST
Phone: 9162162978
e-Mail: permitssac@freedomforever.com
4/30/2024 5:20:53 AM
rpratt changed Inspection Date/Time from 04/30/2024 08:00 AM to 04/30/2024 08:30 AM
4/30/2024 11:33:13 AM
Contractor not ready for inspection and did not cancel ahead of time.
Pay re-inspection fee and recall the inspection when ready.
4/30/2024 12:54:11 PM
Contractor not ready for inspection and did not cancel ahead of time.
Pay re-inspection fee and recall the inspection when ready.
|
|
04/30/2024 | PIER/COLUMN FOOTINGS | RICHARD PRATT | CANCELLED | eTRAKiT Inspection Request | 4/22/2024 2:20:23 PM
4/22/2024 2:20 PM FREEDOM FOREVER LLC
AM if possible
Contact Name: FREEDOM FOREVER LLC
Site Address: 1347 7TH ST
Phone: 9162162978
e-Mail: permitssac@freedomforever.com
4/30/2024 5:20:59 AM
rpratt changed Inspection Date/Time from 04/30/2024 08:00 AM to 04/30/2024 08:30 AM
4/30/2024 11:33:21 AM
Contractor not ready for inspection and did not cancel ahead of time.
Pay re-inspection fee and recall the inspection when ready.
4/30/2024 12:54:19 PM
Contractor not ready for inspection and did not cancel ahead of time.
Pay re-inspection fee and recall the inspection when ready.
|
|
05/03/2024 | UNDERGROUND ELECTRIC | RANDALL SMITH | FAIL | eTRAKiT Inspection Request | 5/1/2024 3:26:56 PM
5/1/2024 3:26 PM FREEDOM FOREVER LLC
AM if possible please
Contact Name: Jose Senior
Site Address: 1347 7TH ST
Phone: 9162162978
e-Mail: permitssac@freedomforever.com
5/3/2024 2:14:27 PM
1. Complete installation of electrical conduit on a flat bed.
2. Call for reinspection when corrections are completed
|
|
05/03/2024 | FOUNDATION/FOOTINGS | RANDALL SMITH | FAIL | eTRAKiT Inspection Request | 5/1/2024 3:26:56 PM
5/1/2024 3:26 PM FREEDOM FOREVER LLC
AM if possible please
Contact Name: Jose Senior
Site Address: 1347 7TH ST
Phone: 9162162978
e-Mail: permitssac@freedomforever.com
5/3/2024 2:14:34 PM
1. Provide footings that are 4 ft 6 in. deep by 2 feet in diameter as per approved set of plans.
2. Clean out the bottom of the footings of rocks and pieces of debris.
3. Call for reinspection when corrections are completed.
|
|
05/03/2024 | SETBACKS | RANDALL SMITH | PASS | | 5/3/2024 2:15:08 PM
Setbacks met dimensions of the approved set of plans.
|
|
05/10/2024 | UNDERGROUND ELECTRIC | WOODY TOWNSEND | FAIL W/RE-INSP FEE | Please call with eta. Thank you | 5/9/2024 7:52:15 AM
5/9/2024 7:52 AM FREEDOM FOREVER LLC
Contact Name: Patrick Jagerson
Site Address: 1347 7TH ST
Phone: 9166397973
e-Mail: permitssac@freedomforever.com
5/10/2024 1:26:37 PM
1. Complete corrections from previous inspection,
RJS 5/3/2024 2:14:27 PM
1. Complete installation of electrical conduit on a flat bed.
RJS 5/3/2024 2:14:34 PM
1. Provide footings that are 4 ft 6 in. deep by 2 feet in diameter as per approved set of plans.
2. Clean out the bottom of the footings of rocks and pieces of debris.
3. Call for reinspection when corrections are completed.
Pay reinspection fee prior to rescheduling inspection.
|
|
05/22/2024 | UNDERGROUND ELECTRIC | CHRISTOPHER ROBERTS | FAIL | eTRAKiT Inspection Request | 5/17/2024 8:30:24 AM
5/17/2024 8:30 AM FREEDOM FOREVER LLC
Contact Name: FREEDOM FOREVER LLC
Site Address: 1347 7TH ST
Phone: 7206775993
e-Mail: permitssac@freedomforever.com
5/22/2024 10:39:52 AM
1. Trench will require a bedding and shading of conduit with sand. Backfill is full of big rocks.
Complete work and call for re-inspection.
|
|
05/22/2024 | PIER/COLUMN FOOTINGS | CHRISTOPHER ROBERTS | PASS | eTRAKiT Inspection Request | 5/17/2024 8:30:24 AM
5/17/2024 8:30 AM FREEDOM FOREVER LLC
Contact Name: FREEDOM FOREVER LLC
Site Address: 1347 7TH ST
Phone: 7206775993
e-Mail: permitssac@freedomforever.com
5/22/2024 10:40:08 AM
Pier/column footings - Approved
|
|
06/05/2024 | ELECTRICAL FINAL | CHRISTOPHER ROBERTS | FAIL | Please call with eta. Thank you | 6/4/2024 11:53:38 AM
6/4/2024 11:53 AM FREEDOM FOREVER LLC
Contact Name: Andres Martinez
Site Address: 1347 7TH ST
Phone: 9169372134
e-Mail: permitssac@freedomforever.com
6/5/2024 12:22:15 PM
1. Missing surge protector type I or type II on MSP as per de-rate of main breaker.
2. Backfill trench from array to house.
** Solar inspected
Complete work and call for re-inspection.
|
|
06/05/2024 | **PERMIT FINAL | CHRISTOPHER ROBERTS | FAIL | Please call with eta. Thank you | 6/4/2024 11:53:38 AM
6/4/2024 11:53 AM FREEDOM FOREVER LLC
Contact Name: Andres Martinez
Site Address: 1347 7TH ST
Phone: 9169372134
e-Mail: permitssac@freedomforever.com
6/5/2024 12:22:21 PM
1. Missing surge protector type I or type II on MSP as per de-rate of main breaker.
2. Backfill trench from array to house.
** Solar inspected
Complete work and call for re-inspection.
|
|
| ELECTRICAL FINAL | | | VOIDED (RDP 6/23/2024) | 6/20/2024 12:56:46 PM
6/20/2024 12:56 PM FREEDOM FOREVER LLC
Contact Name: Jacob Freitas
Site Address: 1347 7TH ST
Phone: 9162064872
e-Mail: permitssac@freedomforever.com
6/23/2024 4:44:05 PM
Inspection voided by RDP. Most recent remarks follow: Please call with eta. Thank you
|
|
06/25/2024 | **PERMIT FINAL | CHRISTOPHER ROBERTS | FAIL W/RE-INSP FEE | Please call with eta. Thank you | 6/20/2024 12:56:46 PM
6/20/2024 12:56 PM FREEDOM FOREVER LLC
Contact Name: Jacob Freitas
Site Address: 1347 7TH ST
Phone: 9162064872
e-Mail: permitssac@freedomforever.com
6/25/2024 3:33:17 PM
1. Corrections were not completed. Trench was not backfilled and no surge protector installed due to electrician thinking they didn't need one. Surge protector required on any MPU or De-Rate of main breaker.
** Pay re-inspection fee, complete work, and call for re-inspection.
|
|
07/26/2024 | **PERMIT FINAL | CHRISTOPHER ROBERTS | PASS | Please call 916-639-7973 with eta. Ty | 7/25/2024 10:15:29 AM
7/25/2024 10:15 AM FREEDOM FOREVER LLC
Contact Name: Patrick Jagerson
Site Address: 1347 7TH ST
Phone: 9166397973
e-Mail: permitssac@freedomforever.com
7/26/2024 8:45:04 AM
croberts changed Inspection Date/Time from 07/26/2024 12:30 PM to 07/26/2024 1:00 PM
7/26/2024 9:20:54 AM
croberts changed Inspection Date/Time from 07/26/2024 01:00 PM to 07/26/2024 12:30 PM
7/26/2024 3:17:47 PM
Prior corrections have been completed.
Permit final - Approved
|
|