Permit No. B23-0169 Permit Type   RESIDENTIAL Site Address   6693 ISHI DR
MAGALIA, CA 95954
Applied   01/24/2023 Applicant   NICOLE MORENO-REDLINE
Approved   03/24/2023 Owner   LORRAINE GARBER
Issued   03/24/2023 Contractor   RED LINE INSTALLATIONS INC
Parent Permit No.   Description   REPL MH PFS(864) OPEN (18) 433A- CAMP FIRE
  Notes  
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

 03/24/2023ENV HEALTH RELEASEPAUL THAOPASS3/24/2023 9:16:03 AM Campfire septic system report passing and site map showing septic system shows setback and replacement area available. Pass

 06/26/2023UNDERGROUND PLUMBINGRAYMOND SANDOVALFAILeTRAKiT Inspection Request6/20/2023 2:54:31 PM 6/20/2023 2:54 PM RED LINE INSTALLATIONS INC Contact Name: RED LINE INSTALLATIONS INC Site Address: 6693 ISHI DR Phone: 5308916719 e-Mail: PERMIT@REDLINEINSTALL.COM 6/26/2023 12:25:38 PM Have plans on site for inspection.

 08/15/2023SETBACKSWOODY TOWNSENDPASSeTRAKiT Inspection Request8/14/2023 12:52:31 PM 8/14/2023 12:52 PM RED LINE INSTALLATIONS INC Contact Name: RED LINE INSTALLATIONS INC Site Address: 6693 ISHI DR Phone: 5308916719 e-Mail: PERMIT@REDLINEINSTALL.COM

 08/15/2023CONTINUITY TESTWOODY TOWNSENDNOT REQUIREDeTRAKiT Inspection Request8/14/2023 12:52:31 PM 8/14/2023 12:52 PM RED LINE INSTALLATIONS INC Contact Name: RED LINE INSTALLATIONS INC Site Address: 6693 ISHI DR Phone: 5308916719 e-Mail: PERMIT@REDLINEINSTALL.COM 8/15/2023 3:46:51 PM Single wide

 08/15/2023BLOCKING/UNDERPINNINWOODY TOWNSENDPASSeTRAKiT Inspection Request8/14/2023 12:52:31 PM 8/14/2023 12:52 PM RED LINE INSTALLATIONS INC Contact Name: RED LINE INSTALLATIONS INC Site Address: 6693 ISHI DR Phone: 5308916719 e-Mail: PERMIT@REDLINEINSTALL.COM

 08/15/2023PERMANENT FOUNDATIONWOODY TOWNSENDPASS

 08/17/2023PGE ELECTRIC TAGWOODY TOWNSENDPASSeTRAKiT Inspection Request8/16/2023 8:58:20 AM 8/16/2023 8:58 AM RED LINE INSTALLATIONS INC Contact Name: RED LINE INSTALLATIONS INC Site Address: 6693 ISHI DR Phone: 5308916719 e-Mail: PERMIT@REDLINEINSTALL.COM

 08/17/2023UNDERFLOOR PLUMBINGWOODY TOWNSENDPASS8/17/2023 3:26:53 PM Pipe and drain test approved.

 09/25/2023433APERMIT CENTERPASSMCO/GRANT DEED IN LF

 10/16/2023CAL FIRE FINAL INSPETROY HANDPASS10/16/2023 3:55:42 PM Met all fire's criteria. Ok to final.

 10/20/2023**PERMIT FINALCHRISTOPHER ROBERTSFAILeTRAKiT Inspection Request10/18/2023 12:12:26 PM 10/18/2023 12:12 PM RED LINE INSTALLATIONS INC Contact Name: RED LINE INSTALLATIONS INC Site Address: 6693 ISHI DR Phone: 5308916719 e-Mail: PERMIT@REDLINEINSTALL.COM 10/20/2023 1:58:17 PM 1. Handrails required on front and rear steps. 2. Repair or replace furnace. 3. Provide proper sloping in front and sides of MH. For every 10' should be a 6" drop in elevation. 4. Armored ground cable needs to be strapped or buried to prevent a trip hazard. Complete work and call for re-inspection.

 11/01/2023**PERMIT FINALRICHARD PRATTPASSeTRAKiT Inspection Request10/30/2023 5:08:41 PM 10/30/2023 5:08 PM RED LINE INSTALLATIONS INC Contact Name: RED LINE INSTALLATIONS INC Site Address: 6693 ISHI DR Phone: 5308916719 e-Mail: PERMIT@REDLINEINSTALL.COM 11/1/2023 4:45:16 AM rpratt changed Inspection Date/Time from 11/01/2023 08:00 AM to 11/01/2023 12:00 PM 11/1/2023 12:59:26 PM Modular Final - Approved