Permit No. B22-4120 Permit Type   MISCELLANEOUS Site Address   4420 SHORTHORN CT
CHICO, CA 95973
Applied   12/20/2022 Applicant   GILMORE CONSTRUCTION & DEVELOPMENT INC
Approved   05/09/2023 Owner   SAYRE PHILIP S & NICOL D
Issued   05/10/2023 Contractor   GILMORE CONSTRUCTION & DEVELOPMENT INC
Parent Permit No.   Description   ADDN RES (1485) COVD (884)
  Notes  
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

ENV HEALTH RELEASEALANA KONGPASS

 06/28/2023ROUGH PLUMBINGCHRISTOPHER ROBERTSPASS067509-01 - Scheduled by IVR.6/28/2023 2:52:01 PM Rough plumbing - Approved

 06/28/2023ROUGH PLUMBINGWOODY TOWNSENDCANCELLED067520-01 - Scheduled by IVR.

 07/05/2023PIER/COLUMN FOOTINGSWOODY TOWNSENDFAIL067521-01 - Scheduled by IVR.7/5/2023 5:32:39 PM Install rebar in pier footings.

 07/05/2023FOUNDATION/FOOTINGSWOODY TOWNSENDPASS067520-02 - Scheduled by IVR.7/5/2023 3:21:36 PM Provide letter from engineer for sand over vapor barrier or remove. 7/5/2023 5:06:08 PM R506.2.3 Vapor Retarder A minimum 10-mil (0.010 inch; 0.254 mm) vapor retarder conforming to ASTM E1745 Class A requirements with joints lapped not less than 6 inches (152 mm) shall be placed between the concrete floor slab and the base course or the prepared subgrade where a base course does not exist. 4.505.2.1 Capillary Break A capillary break shall be installed in compliance with at least one of the following: A 4-inch-thick (101.6 mm) base of 1/2 inch (12.7 mm) or larger clean aggregate shall be provided with a vapor retarder in direct contact with concrete and a concrete mix design, which will address bleeding, shrinkage and curling, shall be used. For additional information, see American Concrete Institute, ACI 302.2R-06. Other equivalent methods approved by the enforcing agency. A slab design specified by a licensed design professional. 7/5/2023 5:25:16 PM Received letter from engineer and attached. Foundation approved.

 07/06/2023PIER/COLUMN FOOTINGSRAYMOND SANDOVALPASS067522-01 - Scheduled by IVR.7/6/2023 10:17:04 AM Previous corrections completed

 07/06/2023PRE-SLABRAYMOND SANDOVALPASS

 07/10/2023GAS PIPINGWOODY TOWNSENDFAIL067630-01 - Scheduled by IVR.7/10/2023 3:45:27 PM No piping to inspect at this time.

 07/20/2023SHEARWALL/B.W.P.-EXTWOODY TOWNSENDPARTIAL067820-01 - Scheduled by IVR.7/20/2023 3:44:43 PM Inspection request for 4 west side shear walls on addition only. No roof installed, trusses on back order and would like to proceed. 4 shear walls approved, see job plans for location. Shear transfer to roof will be at next inspection as no trusses yet.

 07/31/2023ROOF NAILWOODY TOWNSENDFAIL068032-01 - Scheduled by IVR.7/31/2023 4:12:22 PM wtownsend changed Inspection Type from SHEAR TRANSFER to ROOF NAIL 7/31/2023 4:19:30 PM Inspection requested for west side addition only. Okay to cover roof nail in this area after engineers revision to use timber lock screws at patio rafter connection. Will also need engineers revision for missing drag truss at interior shear wall and any shear transfer changes at this location. HDs are installed at this location. Epoxy letter attached.

 08/01/2023ROOF NAILRANDALL SMITHFAIL068034-01 MSG! -Msg! Scheduled by IVR.8/1/2023 5:06:55 PM Contractor requested to put second layer of roof sheathing on south facing roof of west addition. 7/31/23 corrections not completed. Approved second layer of sheathing to be placed only. Can check drag truss nailing once all corrections have been completed. 7/31/2023 WET roof nail inspection Inspection requested for west side addition only. Okay to cover roof nail in this area after engineers revision to use timber lock screws at patio rafter connection. Will also need engineers revision for missing drag truss at interior shear wall and any shear transfer changes at this location. HDs are installed at this location. Epoxy letter attached.

 08/08/2023SHEARWALL/B.W.P.-EXTRICHARD PRATTPASS068190-01 - Scheduled by IVR.8/8/2023 2:54:41 PM Exterior Shearwall installation - Approved

 08/08/2023ROOF NAILRICHARD PRATTPASS8/8/2023 2:54:45 PM Roof nail - Approved

 08/09/2023ROOF NAILWOODY TOWNSENDPASS068191-01 - Scheduled by IVR.8/9/2023 4:30:22 PM All roof nail complete

 08/28/20234-WAY ROUGH FRAMEWOODY TOWNSENDPARTIAL068496-01 - Scheduled by IVR.8/28/2023 3:10:15 PM 1. Provide copy of engineers letter for interior shear connection at garage and approval and installation of Titan anchors replacing all j bolts. 2. Bond gas pipe. Call for interior shear nail at garage after installation.

 08/29/2023GAS TESTCHRISTOPHER ROBERTSPASS068497-01 - Scheduled by IVR.8/29/2023 1:27:05 PM Gas test - APPROVED

 09/07/2023SHEARWALL/B.W.P.-INTLARRY AKERSPASS068727-01 MSG! -Msg! Scheduled by IVR.9/7/2023 3:27:19 PM Last interior shear wall approved

 09/13/2023GAS PIPINGRAYMOND SANDOVALPASS068798-01 - Scheduled by IVR.

 11/14/2023GAS TESTCHRISTOPHER ROBERTSPASS069941-01 MSG! -Msg! Scheduled by IVR.11/14/2023 10:08:38 AM Gas test house - Approved

 02/13/2025SHOWER PAN/TUB TESTWOODY TOWNSENDPASS077088-01 - Scheduled by IVR.

 05/01/2025**PERMIT FINALWOODY TOWNSENDFAIL078261-01 - Scheduled by IVR.5/1/2025 4:03:02 PM 1. Install landing at west exterior door. 2. Install smoke alarms in existing bedrooms. 3. Provide access to gas bond. 4. Connect house gas to underground for future LPG tank location. LPG tank will not be set at this time. Location of tank will meet setbacks when installed. HERs approved. .