Permit No. B22-2528 Permit Type   RESIDENTIAL Site Address   3488 HOFFMAN RD
CONCOW, CA 95965
Applied   08/03/2022 Applicant   JOHN MITCHELL TINY PINE FOUNDATION
Approved   10/06/2022 Owner   HOWELL LOUISE A
Issued   10/11/2022 Contractor   TINY PINE FOUNDATION
Parent Permit No.   MP22-0005 Description   REPL SFD (400) COVD (80) T25, MP22-0005-CAMP FIRE
  Notes  
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

ENV HEALTH RELEASEALANA KONGHOLD FOR SEPTIC FINAL

 11/28/2022FOUNDATION/FOOTINGSRICHARD PRATTPASSeTRAKiT Inspection Request11/23/2022 5:19:07 AM 11/23/2022 5:19 AM Alyssa Nolan Contact Name: John Mitchell Site Address: 3488 HOFFMAN RD Phone: 5306937829 e-Mail: tinypinefoundation@gmail.com 11/28/2022 12:36:48 PM Forms footings and rebar - Approved

 11/28/2022SETBACKSRICHARD PRATTPASS11/28/2022 12:36:57 PM Setbacks checked and Approved

 11/28/2022UNDER SLAB PLUMBINGRICHARD PRATTPASS11/28/2022 12:37:02 PM Underslab plumbing - on test and Approved

 12/06/2022PRE-SLABRANDALL SMITHPASSeTRAKiT Inspection Request12/2/2022 2:21:48 PM 12/2/2022 2:21 PM Alyssa Nolan Am prefered Contact Name: John Mitchell Site Address: 3488 HOFFMAN RD Phone: 5306937829 e-Mail: John@TinyPineFoumdation.org 12/6/2022 9:31:50 AM rjsmith changed Inspection Type from FOUNDATION/FOOTINGS to PRE-SLAB 12/6/2022 9:37:43 AM rjsmith changed Inspection Type from FOUNDATION/FOOTINGS to PRE-SLAB 12/6/2022 11:01:48 AM Ok to pour

 04/12/20244-WAY ROUGH FRAMESCOTT YOUNGFAILam Preferred4/9/2024 10:53:50 AM 4/9/2024 10:53 AM Alyssa Nolan anytime before 1:30 would be much appreciated Contact Name: Alyssa Nolan Site Address: 3488 HOFFMAN RD Phone: 5307201199 e-Mail: tinypinefoundation@gmail.com 4/15/2024 5:39:17 AM 1. Add titans at all anchor bolts that do not have at least 3 threads about nut. ( both sides of front door) approx 5-6 total house. 2. Add anchors at kitchen wall around DWV 3. Prime or paint all DWV protruding through the roof. 4. 2 ground rods required 6' apart with continuous grounding conductor. 5. Mid span straps required on DWV pipes. 6. Upstairs hand rails not finished.

 04/25/2024TAG ELECTRICSCOTT YOUNGPASSeTRAKiT Inspection Request4/23/2024 2:14:10 PM 4/23/2024 2:14 PM W ELECTRIC ENTERPRISES INC am requested please Contact Name: W ELECTRIC ENTERPRISES INC Site Address: 3488 HOFFMAN RD Phone: 5307173253 e-Mail: wee.incorporated@gmail.com 4/25/2024 5:19:55 PM Meter release approved Green tag applied

 05/07/20244-WAY ROUGH FRAMERICHARD PRATTPASSeTRAKiT Inspection Request5/2/2024 10:45:21 AM 5/2/2024 10:45 AM Alyssa Nolan after 9 am but before 2 preferred if possible Contact Name: Alyssa Nolan Site Address: 3488 HOFFMAN RD Phone: 5307201199 e-Mail: tinypinefoundation@gmail.com 5/7/2024 4:07:13 AM Rpratt changed Inspection Date/Time from 05/07/2024 08:00 AM to 05/07/2024 10:30 AM 5/7/2024 3:32:03 PM 4 way frame and trades - Approved

 11/21/2024GAS PIPINGCHRISTOPHER ROBERTSFAILeTRAKiT Inspection Request11/20/2024 10:37:13 AM 11/20/2024 10:37 AM Alyssa Nolan Contact Name: Alyssa Nolan Site Address: 3488 HOFFMAN RD Phone: 5307201199 e-Mail: tinypinefoundation@gmail.com 11/21/2024 7:18:11 AM croberts changed Inspection Date/Time from 11/21/2024 09:00 AM to 11/21/2024 10:00 AM 11/21/2024 10:07:13 AM 1. Gas line trench full of water and mud. Clear trench of water and recall inspection.

 12/04/2024GAS PIPINGRANDALL SMITHPASSeTRAKiT Inspection Request12/2/2024 8:17:14 AM 12/2/2024 8:17 AM Alyssa Nolan Re-inspect Contact Name: Alyssa Nolan Site Address: 3488 HOFFMAN RD Phone: 5307201199 e-Mail: tinypinefoundation@gmail.com

 02/24/2025CAL FIRE FINAL INSPETROY HANDPASS2/6/2025 6:01:41 PM Needs address posted on building. 2/24/2025 11:37:34 AM Has posted address. Ok to final.

 03/06/2025**PERMIT FINALSCOTT YOUNGCANCELLEDeTRAKiT Inspection Request3/5/2025 2:54:45 PM 3/5/2025 2:54 PM Alyssa Nolan Contact Name: Alyssa Nolan Site Address: 3488 HOFFMAN RD Phone: 5307201199 e-Mail: tinypinefoundation@gmail.com

 03/11/2025**PERMIT FINALCHRISTOPHER ROBERTSFAILam prefered3/10/2025 11:48:43 AM 3/10/2025 11:48 AM Alyssa Nolan am preferred Contact Name: Alyssa Nolan Site Address: 3488 HOFFMAN RD Phone: 5307201199 e-Mail: tinypinefoundation@gmail.com 3/11/2025 9:11:43 AM 1. No access, no homeowner or contractor on-site. Arrived at 8:45 am for inspection time between 8:00-10:00, knocked on door, announced presence, nobody home. Recall inspection and provide access.

 03/14/2025**PERMIT FINALCHRISTOPHER ROBERTSFAILeTRAKiT Inspection Request3/13/2025 10:16:10 AM 3/13/2025 10:16 AM Alyssa Nolan Contact Name: Alyssa Nolan Site Address: 3488 HOFFMAN RD Phone: 5307201199 e-Mail: tinypinefoundation@gmail.com 3/14/2025 1:20:53 PM 1. Provide a vacancy sensor for lighting in bathroom as per plans. 2. Install anti-tip device for stove. 3. Provide a receptacle cover for outlet next to fireplace. 4. Seal off line set jack on side of house. 5. Paint or primer galvanized gas line to prevent rust. Complete work and recall inspection.