Permit No. B22-1461 Permit Type   MISCELLANEOUS Site Address   1245 MIDDLEHOFF LN
OROVILLE, CA 95965
Applied   05/02/2022 Applicant   DORM LORD - LG CONSTRUCTION
Approved   08/16/2022 Owner   MARTIN JUSTINE
Issued   08/16/2022 Contractor   L G CONSTRUCTION
Parent Permit No.   Description   DET GAR (576)
  Notes  
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

ENV HEALTH RELEASEYVETTE CASTANONPASS

 02/28/1850NPDESPWLANDDEVVOIDED (KH1 7/14/2022)7/14/2022 2:31:37 PM Inspection voided by KH1.

 08/18/2022FOUNDATION/FOOTINGSADAM KINGSLEYPASS8/18/2022 7:44:00 PM Garage and MH concrete perimeter footing and setbacks -approved. No eufer ground installed.

 01/23/2023SHEARWALL/B.W.P.-EXTRICHARD PRATTFAIL064742-01 - Scheduled by IVR.1/23/2023 6:05:44 AM rpratt changed Inspection Date/Time from 01/23/2023 08:00 AM to 01/23/2023 2:00 PM 1/23/2023 3:07:59 PM See rough framing for notes.

 01/23/2023ROUGH FRAMERICHARD PRATTFAIL064742-03 - Scheduled by IVR.1/23/2023 6:05:51 AM rpratt changed Inspection Date/Time from 01/23/2023 08:00 AM to 01/23/2023 2:00 PM 1/23/2023 3:08:04 PM Provide full structural support for top plate breaks. Finish nailing all H1 Truss hardware to the trusses. Properly nail king studs to the headers. Properly nail sheathing to the trusses where marked. Renail sheathing where fasteners are over driven - check throughout. Recall inspection when completed.

 01/23/2023ROOF NAILRICHARD PRATTFAIL064742-02 - Scheduled by IVR.1/23/2023 6:05:57 AM rpratt changed Inspection Date/Time from 01/23/2023 08:00 AM to 01/23/2023 2:00 PM 1/23/2023 3:08:09 PM See rough framing for notes.

 01/27/2023SHEARWALL/B.W.P.-EXTRANDALL SMITHPASS1/27/2023 2:02:51 PM All previous corrections were completed.

 01/27/2023ROOF NAILRANDALL SMITHPASS1/27/2023 2:02:58 PM All previous corrections were completed

 01/27/2023ROUGH FRAMERANDALL SMITHPASS064859-01 - Scheduled by IVR.1/27/2023 2:02:40 PM rjsmith changed Inspection Type from SHEARWALL/B.W.P.-EXT to ROUGH FRAME 1/27/2023 2:03:54 PM All previous corrections were completed

 03/24/2023CAL FIRE FINAL INSPECHRIS BOYDPASS

 03/24/2023**PERMIT FINALRANDALL SMITHFAIL065672-01 - Scheduled by IVR.3/24/2023 3:49:11 PM 1. Provide approval from Cal Fire. 2. Provide a vent at the gable end as per plans 3. Provide a fire wall running to the roof line separating the garage from the SFD. Cover holes in the firewall next to the stairs. 4. Call for re-inspection when corrections are completed 3/24/2023 3:53:23 PM 1. Provide approval from Cal Fire. 2. Provide a vent at the gable end as per plans 3. Provide a fire wall running to the roof line separating the garage from the SFD. Cover holes in the firewall next to the stairs. 4. Call for re-inspection when corrections are completed 3/24/2023 3:54:54 PM 1. Provide approval from Cal Fire. 2. Provide a vent at the gable end as per plans 3. Provide a fire wall running to the roof line separating the garage from the SFD. Cover holes in the firewall next to the stairs. 4. Call for re-inspection when corrections are completed

 04/12/2023**PERMIT FINALRANDALL SMITHPASS066011-01 - Scheduled by IVR.4/12/2023 4:03:07 PM All previous corrections have been completed 4/12/2023 4:04:09 PM All previous corrections have been completed